FACTORS AFFECTING UNIFORMITY IN INTERPRETATION OF PLANAR TL-201 IMAGING IN A MULTICENTER TRIAL

被引:46
作者
WACKERS, FJT
BODENHEIMER, M
FLEISS, JL
BROWN, M
机构
[1] YALE UNIV,SCH MED,DEPT INTERNAL MED,CARDIOVASC MED SECT,NEW HAVEN,CT 06510
[2] LONG ISL JEWISH MED CTR,DIV ADULT CARDIOL,NEW HYDE PK,NY
[3] COLUMBIA UNIV,SCH PUBL HLTH,DIV BIOSTAT,NEW YORK,NY 10027
[4] UNIV ROCHESTER,HEART RES FOLLOW UP PROGRAM,ROCHESTER,NY 14627
关键词
D O I
10.1016/0735-1097(93)90226-Q
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study was designed te, assess factors affecting interobserver agreement in interpretation of planar thallium-201 stress imaging in the Multicenter Study on Silent Myocardial Ischemia (MSSMI). Background. Five hundred fifty-six planar thallium-201 images were interpreted in 24 clinical centers and in a Radionuclide Core Laboratory. The trial's Coordinating and Data Center observed that the participating clinical centers interpreted a significantly greater number of thallium-201 stress studies as abnormal (i.e., myocardial ischemia or scar) than the Core Laboratory, and overall agreement was poor (kappa 0.27). Methods. Agreement in image interpretation between clinical centers and the Radionuclide Core Laboratory was analyzed by kappa statistics. The reproducibility of the Core Laboratory results on 41 randomly selected test studies was excellent (kappa 0.77). In contrast, the reproducibility of interpretation in the clinical centers on their own studies was at best fair (kappa 0.45). It was hypothesized that the poor agreement and reproducibility in the clinical centers were caused by lack of standardization of image display and lack of objective criteria for image interpretation. To test the effect of standardization, 13 clinical investigators interpreted the same 41 test studies using 1) uniform image display, and 2) uniform quantification of images. Results. The agreement in interpretation between clinical investigators and the Radionuclide Core Laboratory improved modestly with uniformity of image display (kappa 0.57) but improved markedly (kappa 0.66) with quantitative circumferential profile analysis. Conclusions. Lack of standardization in image display and lack of objective criteria for interpretation of thallium-201 images are responsible for suboptimal reproducibility and poor interlaboratory agreement in the interpretation of thallium-201 stress imaging. The adoption of a uniformly accepted method for computer quantification of myocardial perfusion images is crucial to improve agreement in interpretation.
引用
收藏
页码:1064 / 1074
页数:11
相关论文
共 50 条
[41]   BRAIN IMAGING STUDIES USING TL-201 [J].
RUBERTON, JA ;
WOO, DV .
ANATOMICAL RECORD, 1986, 214 (03) :A112-A113
[42]   QUANTITATIVE TL-201 MYOCARDIAL PERFUSION IMAGING [J].
MAISEY, MN .
NUCLEAR MEDICINE COMMUNICATIONS, 1991, 12 (04) :323-327
[43]   DIPYRIDAMOLE TL-201 IMAGING - HOW SAFE IS IT [J].
BELLER, GA .
CIRCULATION, 1990, 81 (04) :1425-1427
[44]   TL-201 STRESS IMAGING IN HYPERTENSIVE PATIENTS [J].
SCHULMAN, DS ;
FRANCIS, CK ;
BLACK, HR ;
WACKERS, FJT .
HYPERTENSION, 1987, 10 (01) :16-21
[45]   TL-201 SPECT IMAGING OF MYOCARDIAL CONTUSION [J].
STRICH, G ;
BRAUNSTEIN, P ;
BRIDGES, R ;
COHEN, A ;
SOLOMON, H ;
WAXMAN, K .
JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) :998-998
[46]   STATIC TESTICULAR IMAGING UTILIZING TL-201 [J].
ONGSENG, F ;
CHERVU, LR ;
KOGAN, SJ ;
FACTOR, SM ;
LEVITT, SB ;
BLAUFOX, MD .
INVESTIGATIVE UROLOGY, 1979, 16 (06) :451-452
[47]   QUANTITATIVE-ANALYSIS OF TOMOGRAPHIC STRESS TL-201 MYOCARDIAL SCINTIGRAMS - A MULTICENTER TRIAL [J].
VANTRAIN, KF ;
MADDAHI, J ;
BERMAN, DS ;
KIAT, H ;
AREEDA, J ;
PRIGENT, F ;
FRIEDMAN, J .
JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (07) :1168-1179
[48]   COMPARISON OF PLANAR SQ30217 AND TL-201 MYOCARDIAL IMAGING WITH CORONARY ANATOMY [J].
JOHNSON, LL ;
SELDIN, DW ;
MUSCHEL, MJ ;
SMITH, KF ;
BLOOD, DK ;
CANNON, PJ .
CIRCULATION, 1987, 76 (04) :217-217
[49]   READERS CONFIDENCE IN INTERPRETATION - RELATIONSHIP TO THE DIAGNOSTIC-ACCURACY OF TL-201 SPECT IMAGING [J].
PRIGENT, F ;
STEINGART, R ;
ROZANSKI, A .
CIRCULATION, 1995, 92 (08) :49-49
[50]   FACTORS INFLUENCING MYOCARDIAL UPTAKE OF TL-201 [J].
SCHELBERT, H ;
INGWALL, J ;
WATSON, R ;
ASHBURN, W .
JOURNAL OF NUCLEAR MEDICINE, 1977, 18 (06) :598-598