Evaluation of a system of passive sampling of CPVC of nitrogen dioxide in the air

被引:0
|
作者
Rojas-Bolanos, Omar [1 ]
Jimenez-Barrantes, Irene [2 ]
机构
[1] Univ Costa Rica, Quim, Ctr Invest Contaminac Ambiental, Lab Calidad Aire, San Jose, Costa Rica
[2] Univ Costa Rica, Quim, Escuela Quim, San Jose, Costa Rica
来源
TECNOLOGIA EN MARCHA | 2012年 / 25卷 / 01期
关键词
Air pollution; active sampling; passive sampling; passive diffusion tubes; nitrogen dioxide; nitric oxide; ozone; CPVC;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Passive diffusion tubes were made to detect NO 2 concentration in the air with chlorinated polyvinyl chloride's tubes (CPVC). Evaluation was carried out by comparing the results obtained in 2008 with the Griess-Saltzman modified method, according to World Health Organization guidelines. Statistical analysis done with linear minimal squares and Wilcoxon ranges and signs found no significant difference between both methods. Relative bias in 7 samples varied from - 19.05% to 24.44% with an average value of 5.76%. Results indicated that the passive tubes overestimated the concentration of NO 2, however, this bias was not greater than the ones reported by other authors. The passive system's precision, measured by variation coefficient in a four tube sample, was in the 5.2% to 10.6% range, again, similar to other reported ranges.