CHEMILUMINOMETRIC L-LYSINE DETERMINATION WITH IMMOBILIZED LYSINE OXIDASE BY FLOW-INJECTION ANALYSIS

被引:34
作者
PREUSCHOFF, F
SPOHN, U
WEBER, E
UNVERHAU, K
MOHR, KH
机构
[1] UNIV HALLE,INST BIOTECHNOL,WEINBERGWEG 16A,O-4050 HALLE,GERMANY
[2] UNIV HALLE,DEPT MED,INST BIOCHEM,O-4020 HALLE,GERMANY
[3] UNIV HALLE,INST MICROBIOL,O-4050 HALLE,GERMANY
关键词
CHEMILUMINESCENCE; ENZYMATIC METHODS; FLOW INJECTION; LYSINE;
D O I
10.1016/0003-2670(93)85120-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzymatic flow-injection procedure for the determination of L-lysine was developed. A lysine oxidase reactor is combined with a fibre-optic hydrogen peroxide detector. Hydrogen peroxide detection is based on the peroxidase-catalysed luminol reaction. The chemiluminescent light is detected by a photomultiplier. L-Lysine can be determined in the range 10-1000 muM. A sampling rate of up to 90 h-1 can be achieved. The whole sensing assay works for more than 1 month. The double logarithmic graph of the peak signal height vs. the lysine concentration is linear, the slope being larger than unity (r2 = 0.991, n = 4).
引用
收藏
页码:185 / 189
页数:5
相关论文
共 50 条
[21]   FLOW-INJECTION CHEMILUMINOMETRIC DETERMINATION OF FOLIC-ACID IN PHARMACEUTICAL FORMULATIONS [J].
ALWARTHAN, AA .
ANALYTICAL SCIENCES, 1994, 10 (06) :919-922
[22]   DETERMINATION OF BRANCHED-CHAIN L-AMINO-ACIDS BY FLOW-INJECTION ANALYSIS WITH CO-IMMOBILIZED LEUCINE DEHYDROGENASE NADH OXIDASE AND CHEMILUMINESCENCE DETECTION [J].
KIBA, N ;
KATO, A ;
FURUSAWA, M .
ANALYTICA CHIMICA ACTA, 1995, 311 (01) :71-76
[23]   Flow-injection chemiluminometric determination of some phenothiazines in dosage forms and biological fluids [J].
Aly, FA ;
Alarfaj, NA ;
Alwarthan, AA .
ANALYTICA CHIMICA ACTA, 1998, 358 (03) :255-262
[24]   DETERMINATION OF L-ASCORBIC-ACID IN FRUIT AND VEGETABLE JUICES BY FLOW-INJECTION WITH IMMOBILIZED ASCORBATE OXIDASE [J].
GREENWAY, GM ;
ONGOMO, P .
ANALYST, 1990, 115 (10) :1297-1299
[25]   FLOW-INJECTION DETERMINATION OF 1,5-ANHYDROGLUCITOL IN SERUM WITH AN IMMOBILIZED PYRANOSE OXIDASE REACTOR AND CHEMILUMINESCENCE DETECTION [J].
KIBA, N ;
UEDA, F ;
SAEGUSA, K ;
GOTO, Y ;
FURUSAWA, M ;
YAMANE, T .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :47-51
[26]   Flow injection chemiluminometric determination of albumin [J].
Deftereos, NT ;
Grekas, N ;
Calokerinos, AC .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :137-143
[27]   FLOW-INJECTION CHEMILUMINOMETRIC DETERMINATION OF CITRATE BASED ON A PHOTOCHEMICAL-REACTION [J].
PEREZRUIZ, T ;
MARTINEZLOZANO, C ;
TOMAS, V ;
VAL, O .
ANALYST, 1995, 120 (02) :471-475
[28]   FLOW-INJECTION CHEMILUMINOMETRIC DETERMINATION OF ASCORBIC-ACID BASED ON ITS SENSITIZED PHOTOOXIDATION [J].
PEREZRUIZ, T ;
MARTINEZLOZANO, C ;
SANZ, A .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :299-307
[29]   Chemiluminometric Determination of the Pesticide Pirimicarb by a Flow Injection Analysis Assembly [J].
Navas Diaz, Aurora ;
Bracho, Visitacion ;
Algarra, Manuel ;
Garcia Sanchez, Francisco .
ANALYTICAL LETTERS, 2008, 41 (17) :3210-3220
[30]   CHEMILUMINESCENCE DETERMINATION OF PROTEASES BY FLOW-INJECTION USING IMMOBILIZED ISOLUMINOL [J].
EDWARDS, R ;
TOWNSHEND, A ;
STODDART, B .
ANALYST, 1995, 120 (01) :117-120