AN INTEGRATED PROCEDURE TO ASSESS KNEE-JOINT KINEMATICS AND KINETICS DURING GAIT USING AN OPTOELECTRIC SYSTEM AND STANDARDIZED X-RAYS

被引:31
作者
LI, J
WYSS, UP
COSTIGAN, PA
DELUZIO, KJ
机构
[1] KING FAISAL SPECIALIST HOSP & RES CTR, RIYADH 11211, SAUDI ARABIA
[2] QUEENS UNIV, DEPT MECH ENGN, KINGSTON K7L 3N6, ONTARIO, CANADA
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1993年 / 15卷 / 05期
关键词
KNEE JOINT; GAIT ANALYSIS; 3-DIMENSIONAL (3-D); INVERSE DYNAMICS APPROACH; JOINT REACTION FORCE; NET MOMENT; CARDAN ANGLES; FLOATING AXIS;
D O I
10.1016/0141-5425(93)90076-B
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a 3-D gait analysis system, which combines optoelectric motion tracking and a standardized X-ray procedure, to calculate the net knee-joint forces and moments of a normal subject group during walking. The optoelectric system collects kinematic data from infra-red LED markers placed at selected skin surface locations and projecting probes attached to the lower limb. A standardized X-ray procedure is used to move surface markers into their designated bony landmarks based on individual bone structure, which reduces the error caused by uncertainty of skin-surface marker locations. Based on moved-in marker information, different joint coordinate systems are proposed for kinematic and kinetic analysis of the knee joint. Normalized data of knee angles, net reaction forces and net moments from 35 young, normal subjects are presented.
引用
收藏
页码:392 / 400
页数:9
相关论文
共 40 条
[31]   AN ANATOMY-BASED COORDINATE SYSTEM FOR THE DESCRIPTION OF THE KINEMATIC DISPLACEMENTS IN THE HUMAN KNEE [J].
PENNOCK, GR ;
CLARK, KJ .
JOURNAL OF BIOMECHANICS, 1990, 23 (12) :1209-1218
[32]  
RAMAKRISHNAN HK, 1987, BIOMECHANICS NORMAL, P87
[33]   A STANDARDIZED TECHNIQUE FOR LOWER-LIMB RADIOGRAPHY - PRACTICE, APPLICATIONS, AND ERROR ANALYSIS [J].
SIU, D ;
COOKE, TDV ;
BROEKHOVEN, LD ;
MIU, L ;
FISHER, B ;
SAUNDERS, G ;
CHALLIS, TW .
INVESTIGATIVE RADIOLOGY, 1991, 26 (01) :71-77
[34]  
SPITZBART A, 1969, ANAL GEOMETRY
[35]   USE OF CARDAN ANGLES TO LOCATE RIGID BODIES IN 3-DIMENSIONAL SPACE [J].
TUPLING, SJ ;
PIERRYNOWSKI, MR .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (05) :527-532
[36]  
Whittle M W, 1989, J Arthroplasty, V4, P231, DOI 10.1016/S0883-5403(89)80019-1
[37]  
Winter D, 1990, BIOMECHANICS HUMAN M
[38]  
WINTER DA, 1983, J MOTOR BEHAV, V15, P302
[39]  
Winter DA, 1991, BIOMECHANICS MOTOR C
[40]  
1989, WATSMART MANUAL