High Performance 3D PET Reconstruction Using Spherical Basis Functions on a Polar Grid

被引:5
作者
Cabello, J. [1 ]
Gillam, J. E. [1 ]
Rafecas, M. [1 ,2 ]
机构
[1] Univ Valencia, CSIC, Edificio Inst Invest, Inst Fis Corpuscular, Valencia 22085, Spain
[2] Univ Valencia, Dept Fis Atom Mol & Nucl, Valencia 46100, Spain
关键词
D O I
10.1155/2012/452910
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Statistical iterative methods are a widely used method of image reconstruction in emission tomography. Traditionally, the image space is modelled as a combination of cubic voxels as a matter of simplicity. After reconstruction, images are routinely filtered to reduce statistical noise at the cost of spatial resolution degradation. An alternative to produce lower noise during reconstruction is to model the image space with spherical basis functions. These basis functions overlap in space producing a significantly large number of non-zero elements in the system response matrix (SRM) to store, which additionally leads to long reconstruction times. These two problems are partly overcome by exploiting spherical symmetries, although computation time is still slower compared to non-overlapping basis functions. In this work, we have implemented the reconstruction algorithm using Graphical Processing Unit (GPU) technology for speed and a precomputed Monte-Carlo-calculated SRM for accuracy. The reconstruction time achieved using spherical basis functions on a GPU was 4.3 times faster than the Central Processing Unit (CPU) and 2.5 times faster than a CPU-multi-core parallel implementation using eight cores. Overwriting hazards are minimized by combining a random line of response ordering and constrained atomic writing. Small differences in image quality were observed between implementations.
引用
收藏
页数:11
相关论文
共 33 条
[1]   Geometrical and Monte Carlo projectors in 3D PET reconstruction [J].
Aguiar, Pablo ;
Rafecas, Magdalena ;
Enrique Ortuno, Juan ;
Kontaxakis, George ;
Santos, Andres ;
Pavia, Javier ;
Ros, Domenec .
MEDICAL PHYSICS, 2010, 37 (11) :5691-5702
[2]   Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction [J].
Alessio, Adam M. ;
Stearns, Charles W. ;
Tong, Shan ;
Ross, Steven G. ;
Kohlmyer, Steve ;
Ganin, Alex ;
Kinahan, Paul E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) :938-949
[3]   Pinhole SPECT reconstruction using blobs and resolution recovery [J].
Andreyev, Andriy ;
Defrise, Michel ;
Vanhove, Christian .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) :2719-2728
[4]   Acceleration of Blob-Based Iterative Reconstruction Algorithm Using Tesla GPU [J].
Andreyev, Andriy ;
Sitek, Arkadiusz ;
Celler, Anna .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :4095-+
[5]   List mode 3D PET reconstruction using an exact system matrix and polar voxels [J].
Ansorge, Richard .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :3454-3457
[6]  
Cabello J, 2010, IEEE NUCL SCI CONF R, P3256, DOI 10.1109/NSSMIC.2010.5874407
[7]   Comparison of basis functions for 3D PET reconstruction using a Monte Carlo system matrix [J].
Cabello, Jorge ;
Rafecas, Magdalena .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07) :1759-1777
[8]   Using Spherical Basis Functions on a Polar Grid for Iterative Image Reconstruction in Small Animal PET [J].
Cabello, Jorge ;
Oliver, Josep F. ;
Rafecas, Magdalena .
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
[9]   Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA [J].
Cui, Jing-yu ;
Pratx, Guillem ;
Prevrhal, Sven ;
Levin, Craig S. .
MEDICAL PHYSICS, 2011, 38 (12) :6775-6786
[10]   Application of the row action maximum likelihood algorithm with spherical basis functions to clinical PET imaging [J].
Daube-Witherspoon, ME ;
Matej, S ;
Karp, JS ;
Lewitt, RM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) :24-30