The effects of cutouts on output, mean energy and percentage depth dose of 12 and 14 MeV electrons

被引:10
作者
Khaledy, Navid [1 ,2 ]
Arbabi, Azim [2 ]
Sardari, Dariush [3 ]
机构
[1] Islamic Azad Univ, Young Res Club Sci & Res Branch, Tehran, Iran
[2] Shahid Beheshti Med Univ, Imam Hosein Hosp, Dept Med Phys, Tehran, Iran
[3] Islamic Azad Univ, Dept Med Radiat, Sci & Res Branch, Tehran, Iran
关键词
Cutout; electron beam; formulization; output factor; profile; percentage depth dose;
D O I
10.4103/0971-6203.89970
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electron field-shaping cerrobend cutouts on the linear accelerator applicator have some effects on the output and percentage depth dose. These effects which arise from the lateral scatter nonequilibrium are particularly evident in higher energies and in cutouts with smaller radius. Dose measurements for circular, square, and triangular cutouts as well as open field was performed in a 10 x 10 cm applicator, using plane parallel type ion chamber with a 100cm source surface distance. The Percentage Depth Doses curves were drawn and the outputs were measured for each of these cutouts. The output factors, normalized to open 10 x 10cm field, varied between 0.891 and 0.996 depending on the energy, cutout shape, and cavity area. With the use of cutouts, R-100 shifted toward the surface. The shifts ranged from 9 to 0mm and from 13 to 0mm for 12 and 14 MeV, respectively, depending on the shape and cavity area. For R-90, R-80, and R-50 the ranges for observed shifts narrowed down and practically no shifts were observed for R-20. We present these changes in the form of predictive formulas, which would be useful in clinical applications.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 14 条
[1]  
Aggarwal LM, 1999, J MED PHYS, V24, P44
[2]  
Andreo P, 2000, IAEA TECHNICAL REPOR, V398
[3]   CALCULATION OF ELECTRON-BEAM DOSE DISTRIBUTIONS FOR ARBITRARILY SHAPED FIELDS [J].
BRUINVIS, IAD ;
VANAMSTEL, A ;
ELEVELT, AJ ;
VANDERLAARSE, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (06) :667-683
[4]   CLINICAL ELECTRON-BEAM DOSIMETRY - REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-25 [J].
KHAN, FM ;
DOPPKE, KP ;
HOGSTROM, KR ;
KUTCHER, GJ ;
NATH, R ;
PRASAD, SC ;
PURDY, JA ;
ROZENFELD, M ;
WERNER, BL .
MEDICAL PHYSICS, 1991, 18 (01) :73-109
[5]   Calculation of depth dose and dose per monitor unit for irregularly shaped electron fields [J].
Khan, FM ;
Higgins, PD ;
Gerbi, BJ ;
Deibel, FC ;
Sethi, A ;
Mihailidis, DN .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2741-2754
[6]  
Khan FM, 2003, PHYS RAD THERAPY, P292
[7]  
Khan FM, 2003, PHYS RAD THERAPY, P267
[8]   FILM DOSIMETRY OF SMALL ELONGATED ELECTRON-BEAMS FOR TREATMENT PLANNING [J].
NIROOMANDRAD, A .
MEDICAL PHYSICS, 1989, 16 (04) :655-662
[9]  
NIROOMANDRAD A, 1986, MED PHYS, V13, P416, DOI 10.1118/1.595887
[10]   Practical considerations for electron beam small field size dosimetry [J].
Sharma, SC ;
Johnson, MW ;
Gossman, MS .
MEDICAL DOSIMETRY, 2005, 30 (02) :104-106