A questionnaire study of radiography educator opinions about patient lead shielding during digital projection radiography

被引:8
|
作者
Shanley, C. [1 ]
Matthews, K. [1 ]
机构
[1] Univ Coll Dublin, Radiog & Diagnost Imaging, Sch Med, Dublin, Ireland
关键词
Patient protection; Organ shielding; Optimisation; Radiation protection; Good practice; Survey;
D O I
10.1016/j.radi.2018.04.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In projection radiography, lead rubber shielding has long been used to protect the gonads both within and outside the collimated field. However, the relative radio-sensitivity of the gonads is considered lower than previously, and doses from digital projection radiography are reported as being lower than in previous eras. These factors, along with technical difficulties encountered in placing lead shielding effectively, lead to varied opinions on the efficacy of such shielding in peer reviewed literature. This current study has investigated what is currently being taught as good practice concerning the use of lead shielding during projection radiography. Method: An online questionnaire was distributed to a purposive sample of 44 radiography educators across 15 countries, with the aim of establishing radiography educators' opinions about patient lead shielding and its teaching. Results: From the 27 responding educators, 57% (n = 15) teach students to apply gonadal shielding across a range of radiographic examinations; only 22% (n = 6) do the same for the breast, despite respondents being aware that the breast has higher relative radio-sensitivity than the gonads. Radiation protection was the primary reason given for using shielding. Students are generally expected to apply patient lead shielding during assessments, although a small number of respondents report that students must justify whether or not to apply lead shielding. Educators generally held the opinion that no matter what they are taught, students are influenced by what they see radiographers do in clinical practice. Conclusions: The current study has not found consensus in literature or in radiography educators' opinions concerning the use of patient lead shielding. Findings suggest that a large scale empirical study to establish a specific evidence base for the appropriate use of lead shielding across a range of projection radiography examinations would be useful. (c) 2018 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:328 / 333
页数:6
相关论文
共 29 条
  • [1] Patient dose in digital projection radiography
    Compagnone, Gaetano
    Pagan, Laura
    Baleni, Massimo Casadio
    Calzolaio, Felice Luca
    Barozzi, Libero
    Bergamini, Carlo
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 135 - 137
  • [2] Gonad contact shielding in digital radiography: A questionnaire survey
    Cardoso, Carlos Eduardo Martins Dias
    Bezzina, Paul
    Portelli, Jonathan L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158
  • [3] Transition from screen-film to digital radiography:: Evolution of patient radiation doses at projection radiography
    Vano, Eliseo
    Fernandez, Jose Miguel
    Ten, Jose Ignacio
    Prieto, Carlos
    Gonzalez, Luciano
    Rodriguez, Ricardo
    de Las Heras, Hugo
    RADIOLOGY, 2007, 243 (02) : 461 - 466
  • [4] Effect of Lead Shielding on Patient Dose in Digital Radiography with Automatic Exposure Control (AEC) Driven Imaging Systems
    Gautam, A.
    Kroger, L.
    Barton, K.
    Hodge, B.
    Seibert, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E258 - E258
  • [5] A dose index as a tool to estimate paediatric patient doses in digital projection radiography
    Garcia Castanon, Paula
    Espana Lopez, Maria Luisa
    Fernandez Bedoya, Virginia
    Bermudez Luna, Rocio
    Rodriguez Martin, Gabriel
    RADIATION PROTECTION DOSIMETRY, 2012, 149 (04) : 417 - 423
  • [6] Blood and Hand Surface Lead in Veterinary Workers Using Lead Shielding During Diagnostic Radiography
    Mayer, Monique
    Feng, Tongchen
    Sukut, Sally
    Wiebe, Sheldon
    Parker, Sarah
    Blakley, Barry
    Koehncke, Niels
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2023, 65 (09) : 794 - 797
  • [7] Effectiveness of Breast and Eye Shielding During Cervical Spine Radiography: An Experimental Study
    Elshami, Wiam
    Abuzaid, Mohamed M.
    Tekin, H. O.
    RISK MANAGEMENT AND HEALTHCARE POLICY, 2020, 13 : 697 - 704
  • [8] Patient shielding during dentomaxillofacial radiography Recommendations from the American Academy of Oral and Maxillofacial Radiology
    Benavides, Erika
    Bhula, Avni
    Gohel, Anita
    Lurie, Alan G.
    Mallya, Sanjay M.
    Ramesh, Aruna
    Tyndall, Donald A.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2023, 154 (09): : 826 - 835.e2
  • [9] OPTIMIZING IMAGE QUALITY, RADIATION DOSAGE TO THE PATIENT AND TO THE DETECTOR IN PEDIATRIC CHEST RADIOGRAPHY: A PHANTOM STUDY OF A PORTABLE DIGITAL RADIOGRAPHY SYSTEM
    Shahgeldi, Kaveh
    Sjoberg, Tommy
    Nordstrom, Jonny
    Lesanu, Radu
    Svahn, Tony Martin
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (04) : 414 - 420
  • [10] Does digital radiography increase the number of intraoral radiographs? A questionnaire study of Dutch dental practices
    Berkhout, WER
    Sanderink, GCH
    Van der Stelt, PF
    DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (02) : 124 - 127