HIGH-RESOLUTION ELECTRON-MICROSCOPY OBSERVATION OF THE FINE-STRUCTURE OF CU-ZN-AL MARTENSITES

被引:9
|
作者
WANG, R [1 ]
LUO, C [1 ]
GUI, J [1 ]
REN, Q [1 ]
CHEN, J [1 ]
机构
[1] NANJING UNIV,SOLID STATE MICROSTRUCT LAB,NANJING 210008,PEOPLES R CHINA
关键词
D O I
10.1088/0953-8984/4/10/006
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
The fine structure of martensites in step-quenched Cu-17.4 at.% Zn-13.0 at.% Al alloy has been observed using high-resolution electron microscopy. It has been found that, besides the 18R1 martensite occurring most frequently, there exist also 6R and 2H martensites in local regions. Stacking faults, extended dislocations with Burgers vector 1/4[210]6R and basal plane twins have also been observed in 6R martensite. The planarity and coherency of the (2, 0, 20)18R1 A-D twin boundary of 18R1 martensite are much less than those of the (128BAR)18R1 A-C twin boundary. Edge dislocations, whose Burgers vector has a component in the [001]18R1 direction, have been observed near the (2, 0, 20)18R1 boundary.
引用
收藏
页码:2397 / 2403
页数:7
相关论文
共 50 条
  • [1] GAMMA PRECIPITATES IN CU-ZN-AL ALLOYS STUDIED BY HIGH-RESOLUTION ELECTRON-MICROSCOPY
    PONS, J
    PORTIER, R
    JOURNAL DE PHYSIQUE IV, 1995, 5 (C2): : 245 - 250
  • [2] THE HIGH-RESOLUTION ELECTRON-MICROSCOPY OF STACKING DEFECTS IN CU-ZN-AL SHAPE MEMORY ALLOY
    COOK, JM
    OKEEFE, MA
    SMITH, DJ
    STOBBS, WM
    JOURNAL OF MICROSCOPY, 1983, 129 (MAR) : 295 - 306
  • [3] HIGH-RESOLUTION ANALYTICAL ELECTRON-MICROSCOPY STUDY ON THE BAINITIC TRANSFORMATION IN A CU-ZN-AL ALLOY
    NAKATA, Y
    TADAKI, T
    SHIMIZU, K
    MATERIALS TRANSACTIONS JIM, 1989, 30 (02): : 107 - 116
  • [4] HIGH-RESOLUTION ELECTRON-MICROSCOPY IMAGING OF THE HABIT PLANE IN CU-ZN-AL SHAPE MEMORY ALLOYS
    LOVEY, FC
    VANTENDELOO, G
    VANLANDUYT, J
    SCRIPTA METALLURGICA, 1987, 21 (12): : 1627 - 1631
  • [5] A HIGH-RESOLUTION ELECTRON-MICROSCOPY STUDY OF THE FINE-STRUCTURE IN A TRENCH CAPACITOR
    SINCLAIR, R
    KIM, KB
    SHIPPOU, O
    IWASAKI, H
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (02) : 511 - 518
  • [6] ELECTRON-MICROSCOPY OF INTERNALLY FAULTED CU-ZN-AL MARTENSITE
    CHAKRAVORTY, S
    WAYMAN, CM
    ACTA METALLURGICA, 1977, 25 (09): : 989 - 1000
  • [7] AN APPLICATION OF HIGH-RESOLUTION TRANSMISSION ELECTRON-MICROSCOPY TO THE STUDY OF THE FINE-STRUCTURE OF DISLOCATIONS IN POTASSIUM FELDSPARS
    ZHENG, YL
    GANDAIS, M
    JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1989, 11 (03): : 234 - 237
  • [8] HIGH-RESOLUTION ELECTRON-MICROSCOPY OF FINE PARTICLES
    MITOME, M
    OHSHIMA, Y
    ITOH, M
    TAKAYANAGI, K
    MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1993, 4 (2-3): : 297 - 304
  • [9] THE EFFECT OF THERMAL-TREATMENT ON THE STRUCTURE AND FINE-STRUCTURE OF CU-ZN-AL MARTENSITE
    GUI, JN
    LUO, CH
    ZHANG, HG
    HU, W
    WANG, RH
    JOURNAL OF MATERIALS SCIENCE, 1990, 25 (03) : 1675 - 1681
  • [10] HIGH-RESOLUTION ELECTRON-MICROSCOPIC INSITU OBSERVATION OF THE MOTION OF INTERVARIANT INTERFACES IN CU-ZN-AL THERMOELASTIC MARTENSITE
    KATATA, T
    SAKA, H
    PHILOSOPHICAL MAGAZINE A-PHYSICS OF CONDENSED MATTER STRUCTURE DEFECTS AND MECHANICAL PROPERTIES, 1989, 59 (03): : 677 - 686