INTERLABORATORY COMPARISON OF RADIATION-INDUCED ATTENUATION IN OPTICAL FIBERS .2. STEADY-STATE EXPOSURES

被引:35
作者
TAYLOR, EW
FRIEBELE, EJ
HENSCHEL, H
WEST, RH
KRINSKY, JA
BARNES, CE
机构
[1] USN,RES LAB,DIV OPT SCI,OXIDE MAT RES GRP,WASHINGTON,DC 20375
[2] ROYAL MIL COLL SCI,APPL PHYS & ELECTROOPT GRP,SHRIVENHAM,ENGLAND
[3] FRAUNHOFER INS BOEING AEROSP & ELECTR,DEPT PHYS,SEATTLE,WA
[4] AEROSPACE CORP,LOS ANGELES,CA 90009
关键词
D O I
10.1109/50.54517
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report herein the results of a series of round-robin experiments performed under strict procedures to determine the measurement veracity by which eventual standards may be established for measuring the effects of steady-state ionizing radiation on optical fibers. The responses of step index multimode, graded index multimode, and single-mode optical fibers exposed to ionizing radiations were measured by eight laboratories of the NATO Panel IV Research Study Group 12, Nuclear Effects Task Group, during the period of 1987-1989. The studies revealed that fiber wrap diameter, radiation dose rates, and launched power levels significantly influenced the measured radiation-induced attenuation in silica core multimode and single-mode fibers, while variations in these parameters did not affect the resposes of Ge-doped silica core multimode fibers as severely. Mode scrambling and mode stripping were found not to be influential factors for increasing the measurement accuracies in either graded or step index fibers. Significant improvement in measurement accuracies from earlier studies was noted by reduction of the measurement deviation among the laboratories from greater than 25% to less than 7% of the peak induced attenuation. Discussion is focused on other important test parameters including: radiation dose, dose rates, accuracy of dosimetry, photobleaching, and instrumentation. © 1990 IEEE
引用
收藏
页码:967 / 975
页数:9
相关论文
共 8 条
[1]   PHOTOBLEACHING EFFECTS IN OPTICAL FIBER WAVE-GUIDES [J].
FRIEBELE, EJ ;
GINGERICH, ME .
APPLIED OPTICS, 1981, 20 (19) :3448-3452
[2]   INTERLABORATORY COMPARISON OF RADIATION-INDUCED ATTENUATION IN OPTICAL FIBERS .1. STEADY-STATE EXPOSURES [J].
FRIEBELE, EJ ;
TAYLOR, EW ;
DEBEAUREGARD, GT ;
WALL, JA ;
BARNES, CE .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1988, 6 (02) :165-171
[3]  
FRIEBELE EJ, 1989, IN PRESS J LIGHTWAVE
[4]  
Henschel H., 1989, Proceedings of the SPIE - The International Society for Optical Engineering, V992, P96, DOI 10.1117/12.960034
[5]  
Schneider W., 1986, P SPIE INT SOC OPT E, V721, P89
[6]  
TAYLOR EW, 1986, P OPTO 86, P477
[7]   CHARACTERISTICS OF LIGHT-INDUCED ANNEALING IN IRRADIATED OPTICAL FIBERS [J].
WEST, RH ;
LENHAM, AP .
ELECTRONICS LETTERS, 1982, 18 (11) :483-484
[8]   A LOCAL VIEW OF RADIATION EFFECTS IN FIBER OPTICS [J].
WEST, RH .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1988, 6 (02) :155-164