AMPEROMETRIC BIOSENSING OF ALCOHOLS AT ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ENZYME ELECTRODES

被引:6
作者
WANG, J [1 ]
GONZALEZROMERO, E [1 ]
机构
[1] LAB QUIM ANALIT,E-32004 ORENSE,SPAIN
关键词
ELECTROCHEMICAL PRETREATMENT; ALCOHOL SENSOR; ENZYME ELECTRODE;
D O I
10.1002/elan.1140050509
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Substantial improvements in the performance of amperometric biosensors for alcohols are achieved by subjecting the glassy carbon transducer to an electrochemical pretreatment prior to the immobilization of alcohol dehydrogenase. The enzymatically generated dihydronicotinamide adenine dinucleotide (NADH) can thus be detected at a substantially (approximately 340 mV) lower potential compared to the untreated surface. Hence, highly sensitive low-potential amperometric sensing of alcohols is accomplished without the assistance of a surface-bound electron mediator. Applicability to alcoholic beverages is illustrated.
引用
收藏
页码:427 / 430
页数:4
相关论文
共 12 条
[1]   ELECTROCHEMICAL ACTIVATION OF CARBON ELECTRODES IN BASE - MINIMIZATION OF DOPAMINE ADSORPTION AND ELECTRODE CAPACITANCE [J].
ANJO, DM ;
KAHR, M ;
KHODABAKHSH, MM ;
NOWINSKI, S ;
WANGER, M .
ANALYTICAL CHEMISTRY, 1989, 61 (23) :2603-2608
[2]   STUDY OF ELECTROCHEMICAL OXIDATION OF REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE [J].
BLAEDEL, WJ ;
JENKINS, RA .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1337-1343
[3]  
BOYER PD, 1975, ENZYMES, V11, P184
[4]   AMPEROMETRIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION OF NADH AT A BASE-ACTIVATED GLASSY-CARBON ELECTRODE [J].
EISENBERG, EJ ;
CUNDY, KC .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :845-847
[5]   ELECTROCHEMICAL PRETREATMENT OF GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2310-2314
[6]   CHEMICALLY MODIFIED ELECTRODES FOR THE ELECTROCATALYTIC OXIDATION OF NICOTINAMIDE COENZYMES [J].
GORTON, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1245-1258
[7]   SURFACE PREPARATION OF GLASSY-CARBON ELECTRODES [J].
KAMAU, GN .
ANALYTICA CHIMICA ACTA, 1988, 207 (1-2) :1-16
[8]   PRETREATMENT OF GLASSY-CARBON ELECTRODES BY ANODIC GALVANOSTATIC PULSES WITH A LARGE-AMPLITUDE [J].
MATTUSCH, J ;
HALLMEIER, KH ;
STULIK, K ;
PACAKOVA, V .
ELECTROANALYSIS, 1989, 1 (05) :405-412
[9]   OPTIMIZATION OF THE ANALYTICAL OXIDATION OF DIHYDRONICOTINAMIDE ADENINE-DINUCLEOTIDE AT CARBON AND PLATINUM-ELECTRODES [J].
MOIROUX, J ;
ELVING, PJ .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :346-350
[10]   ELECTROCATALYSIS OF DIHYDRONICOTINAMIDE ADENOSINE-DIPHOSPHATE WITH QUINONES AND MODIFIED QUINONE ELECTRODES [J].
TSE, DCS ;
KUWANA, T .
ANALYTICAL CHEMISTRY, 1978, 50 (09) :1315-1318