MAGNETIC-RESONANCE ASSESSMENT OF THE PULMONARY ARTERIAL TRUNK ANATOMY, FLOW, PULSATILITY AND DISTENSIBILITY

被引:56
作者
PAZ, R [1 ]
MOHIADDIN, RH [1 ]
LONGMORE, DB [1 ]
机构
[1] ROYAL BROMPTON NATL HEART & LUNG HOSP, MAGNET RESONANCE UNIT, LONDON, ENGLAND
关键词
PULMONARY ARTERIES; MAGNETIC RESONANCE; BLOOD FLOW; DISTENSIBILITY; PULSATILITY;
D O I
10.1093/eurheartj/14.11.1524
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We used magnetic resonance imaging with cine velocity mapping to study the anatomy of pulmonary bifurcation and to measure volume blood flow, pulsatility of flow and arterial wall distensibility in the central pulmonary arteries of nine healthy volunteers. Multislice, multiplane spin echo images were acquired to display pulmonary bifurcation anatomy. Diameters of the main pulmonary artery (MPA) in systole were 2.56 ± 0.35 cm and in diastole 2.20 ± 0.33 cm. Those of the right pulmonary artery (RPA) were 1.57 ± 0.29 cm and 1.39 ± 0.23 respectively, and of the left pulmonary artery (LPA) 1.79 ± 0.26 cm and 1.55 ± 0.10 cm respectively. A gradient echo sequence with phase shift velocity mapping was then used to measure flow in MPA, RPA and LPA 2 cm on either side of the pulmonary bifurcation. Time averaged flow, calculated from mean velocity and the cross-sectional area of the vessels was 4.99 ± 1.10 l . min-1 in MPA, 2.23 ± 0.58 l . min-1 in RPA and 2.31 ± 0.63 l. min-1 in LPA. The pulsatility index of flow derived from peak forward flow, peak backward flow and time averaged flow were as follows: MPA 4 4 ± 0.8, RPA 5.1 ± 0.6 and LPA 4.6 ± 1.5. Distensibility, calculated from the change in cross-sectional area between diastole and systole and expressed as percentage were as follows: MPA 25.6 ± 10.7, RPA 21.4 ± 10.7 and LPA 24.5 ± 7.8.MRI with velocity mapping accurately characterized anatomy, flow, distensibility and pulsatility of the central pulmonary arteries. © 1993 The European Society of Cardiology.
引用
收藏
页码:1524 / 1530
页数:7
相关论文
共 25 条
[1]   PULMONARY-ARTERY DISTENSIBILITY AND BLOOD-FLOW PATTERNS - A MAGNETIC-RESONANCE STUDY OF NORMAL SUBJECTS AND OF PATIENTS WITH PULMONARY ARTERIAL-HYPERTENSION [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
MOHIADDIN, RH ;
FIRMIN, DN ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 118 (05) :990-999
[2]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[3]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[4]   INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756
[5]  
FIRMIN DN, 1989, SOC MAGNETIC RESONAN, P888
[6]   PULMONARY VASCULAR CINE MR IMAGING - A NONINVASIVE APPROACH TO DYNAMIC IMAGING OF THE PULMONARY CIRCULATION [J].
GEFTER, WB ;
HATABU, H ;
DINSMORE, BJ ;
AXEL, L ;
PALEVSKY, HI ;
REICHEK, N ;
SCHIEBLER, ML ;
KRESSEL, HY .
RADIOLOGY, 1990, 176 (03) :761-770
[7]  
HARRIS P, 1986, HUMAN PULMONARY CIRC, P94
[8]   VALVE AND GREAT VESSEL STENOSIS - ASSESSMENT WITH MR JET VELOCITY MAPPING [J].
KILNER, PJ ;
FIRMIN, DN ;
REES, RSO ;
MARTINEZ, J ;
PENNELL, DJ ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
LONGMORE, DB .
RADIOLOGY, 1991, 178 (01) :229-235
[9]   PULMONARY-HYPERTENSION - PULMONARY FLOW QUANTIFICATION AND FLOW PROFILE ANALYSIS WITH VELOCITY-ENCODED CINE MR IMAGING [J].
KONDO, C ;
CAPUTO, GR ;
MASUI, T ;
FOSTER, E ;
OSULLIVAN, M ;
STULBARG, MS ;
GOLDEN, J ;
CATTERJEE, K ;
HIGGINS, CB .
RADIOLOGY, 1992, 183 (03) :751-758
[10]  
LIGHTY GW, 1985, J AM COLL CARDIOL, V5, P499