A HIGH-RESOLUTION PET FOR ANIMAL STUDIES

被引:116
|
作者
WATANABE, M
UCHIDA, H
OKADA, H
SHIMIZU, K
SATOH, N
YOSHIKAWA, E
OHMURA, T
YAMASHITA, T
TANAKA, E
机构
[1] Hamamatsu Photonics K.K., Hamakita-city, 434, Hirakuchi
关键词
D O I
10.1109/42.192694
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A new high resolution positron emission tomography (PET) system dedicated to in vivo animal studies has been developed. A block detector, which is a position-sensistive photomultiplier tube (Hamamatsu R3941-02) coupled to 4 arrays of 1.7 mm wide BGO crystals has been adopted to the system. There are 15 block detectors positioned to form a 35 cm diameter ring, with the coupling of 4 BGO arrays to each PMT. This provides 4 detector rings, giving the system a 7 slice imaging capability. The gantry head tilts up to +/- 90-degrees, and is capable of moving up and down by 30 cm. These positioning capabilities allow flexibility and great ease of use in subject positioning. Also, a gantry entrance size of 22 cm in diameter allows studies ranging from rats and mice to primates such as Rhesus and squirrel monkeys. The physical performance of the system has been evaluated. The spatial resolution in the center of the field of view (FOV) is 3.0 mm at full width at half maximum (FWHM) in the transaxial plane. The axial resolution at the center of the FOV is 4.8 mm FWHM in the direct plane, and 4.1 mm FWHM in the cross plane. The total system sensitivity is 20.7 kcps/muCi/ml for a 10 cm diameter cylindrical uniform phantom with an energy threshold of 300 keV.
引用
收藏
页码:577 / 580
页数:4
相关论文
共 50 条
  • [1] Conceptual design studies for a high-resolution, high-sensitivity animal PET system.
    Weber, S
    Bauer, A
    Herzog, HR
    Pietrzyk, U
    Streun, M
    Ziemons, K
    Coenen, HH
    Zilles, K
    Halling, H
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 19P - 19P
  • [2] DEVELOPMENT OF CONTINUOUS DETECTORS FOR A HIGH-RESOLUTION ANIMAL PET SYSTEM
    SIEGEL, S
    CHERRY, SR
    RICCI, AR
    SHAO, YP
    PHELPS, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1069 - 1074
  • [3] HIGH-RESOLUTION PET STUDIES IN ALZHEIMERS-DISEASE
    KUMAR, A
    SCHAPIRO, MB
    GRADY, C
    HAXBY, JV
    WAGNER, E
    SALERNO, JA
    FRIEDLAND, RP
    RAPOPORT, SI
    NEUROPSYCHOPHARMACOLOGY, 1991, 4 (01) : 35 - 46
  • [4] DEVELOPMENT OF A HIGH-RESOLUTION POSITRON CT FOR ANIMAL STUDIES
    TOMITANI, T
    NOHARA, N
    MURAYAMA, H
    YAMAMOTO, M
    TANAKA, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 822 - 825
  • [5] Multi-resolution image reconstruction for a high-resolution small animal PET device
    Clinthorne, NH
    Park, S
    Rogers, WL
    Chiao, PC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1997 - 2001
  • [6] Performance of a PET Insert for High-Resolution Small-Animal PET/MRI at 7 Tesla
    Stortz, Greg
    Thiessen, Jonathan D.
    Bishop, Daryl
    Khan, Muhammad Salman
    Kozlowski, Piotr
    Retiere, Fabrice
    Schellenberg, Graham
    Shams, Ehsan
    Zhang, Xuezhu
    Thompson, Christopher J.
    Goertzen, Andrew L.
    Sossi, Vesna
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (03) : 536 - 542
  • [7] First results from a high-resolution small animal PET insert for PET/MRI imaging
    Andrew Goertzen
    Greg Stortz
    Jonathan Thiessen
    Daryl Bishop
    Muhammad Salman Khan
    Piotr Kozlowski
    Fabrice Retiere
    Graham Schellenberg
    Vesna Sossi
    Christopher Thompson
    EJNMMI Physics, 2 (Suppl 1)
  • [8] DEVELOPMENT OF A HIGH-RESOLUTION PET
    YAMASHITA, T
    UCHIDA, H
    OKADA, H
    KURONO, T
    TAKEMORI, T
    WATANABE, M
    SHIMIZU, K
    YOSHIKAWA, E
    OHMURA, T
    SATOH, N
    TANAKA, E
    NOHARA, N
    TOMITANI, T
    YAMAMOTO, M
    MURAYAMA, H
    ENDO, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 594 - 599
  • [9] Development of a LGSO detector using a tapered fiber for a high-resolution animal PET
    Yamamoto, S
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1611 - 1614
  • [10] High-resolution PET & high-resolution MRI assessment of hand osteoarthritis
    Tan, A.
    Waller, M.
    Grainger, A.
    Tanner, S.
    Emery, P.
    Benjamin, M.
    McGonagle, D.
    ANNALS OF THE RHEUMATIC DISEASES, 2006, 65 : 21 - 22