Reliability and validity of an electronic dynamometer for measuring grip strength

被引:30
|
作者
Allen, Deborah [1 ]
Barnett, Fiona [1 ]
机构
[1] James Cook Univ, Occupat Therapy Discipline, Townsville, Qld, Australia
关键词
dynamometer; grip strength; test-retest;
D O I
10.12968/ijtr.2011.18.5.258
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Aims: This article describes a study aiming to establish the concurrent validity and test-retest reliability of the Biometrics E-LINK EP9 electronic dynamometer. Methods: Grip strength testing was performed on 49 healthy participants. Three trials were completed for the right and left hands on the Biometrics and Jamar dynamometers, using a repeated measures design. Data was compared and used to establish concurrent validity of the Biometrics dynamometer. Fifteen participants repeated the testing a week later, for test-retest reliability of the Biometrics dynamometer. Findings: The Biometrics E-LINK EP9 evaluation system was found to have excellent validity (ICC 0.983-0.986). However, a small but statistically significant difference between the right hand grip strength scores of the Biometrics (31.65 +/- 8.89) and Jamar (30.44 +/- 9.49) dynamometer was revealed (p <= 0.05). Test-retest reliability of the Biometrics system proved excellent, with ICC scores of 0.986 for the left hand and 0.996 for the right hand. Conclusions: The results indicate that the Biometrics E-LINK EP9 evaluation system is valid, reliable and comparable to the Jamar hydraulic dynamometer, when used for measuring grip strength with the second handle position. However, due to the statistically significant differences found for the right hand grip strength scores, therapists should exercise caution when interchanging instruments.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [21] Reliability and validity of indices of hand-grip strength and endurance
    Reuter, Stephanie E.
    Massy-Westropp, Nicola
    Evans, Allan M.
    AUSTRALIAN OCCUPATIONAL THERAPY JOURNAL, 2011, 58 (02) : 82 - 87
  • [22] Comparison of the BTE tech EVJ handgrip to the Jamar hand dynamometer for measuring grip strength
    Myers, Edwin J.
    Dominguez, David S.
    Guigliano, Melissa E.
    Mallory, Melissa G.
    TECHNOLOGY AND DISABILITY, 2021, 33 (03) : 221 - 227
  • [23] JAMAR DYNAMOMETER AND ADAPTED SPHYGMOMANOMETER FOR MEASURING GRIP STRENGTH IN PATIENTS WITH RHEUMATOID-ARTHRITIS
    AGNEW, PJ
    MAAS, F
    OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1991, 11 (05): : 259 - 270
  • [24] Validity and reliability of a portable handheld dynamometer compared to a fixed isokinetic dynamometer to assess forearm torque strength
    Bonhof-Jansen, E. D. J.
    van Ham, A.
    Kroon, G. J.
    Winter, R. W.
    Brink, S. M.
    HAND SURGERY & REHABILITATION, 2023, 42 (02): : 147 - 153
  • [25] Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength
    Jubany, Julia
    Busquets, Albert
    Marina, Michel
    Cos, Francesc
    Angulo-Barroso, Rosa
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2015, 28 (02) : 317 - 326
  • [26] Validity and Reliability of upper limb muscles strength measurements by handheld dynamometer in COPD
    Beaumont, M.
    Peran, L.
    Berriet, A.
    Keller, R.
    Le Ber, C.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [27] Visual Feedback and Weight Reduction of a Grip Strength Dynamometer Do Not Increase Reliability in Healthy Children
    Molenaar, H. M.
    de Kraker, Marjolein
    Zuidam, J. Michiel
    Hovius, Steven E. R.
    Stam, Henk J.
    Selles, Ruud W.
    JOURNAL OF HAND THERAPY, 2010, 23 (03) : 272 - 279
  • [28] Reliability and validity of the finger flexor dynamometer
    Nestler, Kai
    Rohde, Ulrich
    Becker, Benjamin
    Waldeck, Stephan
    Veit, Daniel A.
    Leyk, Dieter
    HAND THERAPY, 2019, 24 (03) : 82 - 90
  • [29] Grip strength dynamometry: Reliability and validity for adults with upper limb burns
    Clifford, Merci S.
    Hamer, Peter
    Phillips, Michael
    Wood, Fiona M.
    Edgar, Dale W.
    BURNS, 2013, 39 (07) : 1430 - 1436
  • [30] Reliability and Validity of the Martin Vigorimeter for Grip Strength Measurement in Korean Adults
    Lee, Jeong Kil
    Jung, Meesun
    Lee, Han Byul
    Chung, Hyung Jin
    Lee, Seung Hoo
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (04) : 610 - 619