Reliability and validity of an electronic dynamometer for measuring grip strength

被引:30
|
作者
Allen, Deborah [1 ]
Barnett, Fiona [1 ]
机构
[1] James Cook Univ, Occupat Therapy Discipline, Townsville, Qld, Australia
关键词
dynamometer; grip strength; test-retest;
D O I
10.12968/ijtr.2011.18.5.258
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Aims: This article describes a study aiming to establish the concurrent validity and test-retest reliability of the Biometrics E-LINK EP9 electronic dynamometer. Methods: Grip strength testing was performed on 49 healthy participants. Three trials were completed for the right and left hands on the Biometrics and Jamar dynamometers, using a repeated measures design. Data was compared and used to establish concurrent validity of the Biometrics dynamometer. Fifteen participants repeated the testing a week later, for test-retest reliability of the Biometrics dynamometer. Findings: The Biometrics E-LINK EP9 evaluation system was found to have excellent validity (ICC 0.983-0.986). However, a small but statistically significant difference between the right hand grip strength scores of the Biometrics (31.65 +/- 8.89) and Jamar (30.44 +/- 9.49) dynamometer was revealed (p <= 0.05). Test-retest reliability of the Biometrics system proved excellent, with ICC scores of 0.986 for the left hand and 0.996 for the right hand. Conclusions: The results indicate that the Biometrics E-LINK EP9 evaluation system is valid, reliable and comparable to the Jamar hydraulic dynamometer, when used for measuring grip strength with the second handle position. However, due to the statistically significant differences found for the right hand grip strength scores, therapists should exercise caution when interchanging instruments.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [1] Reliability and validity of an electronic dynamometer for measuring grip strength COMMENT
    Fitinghoff, Helene
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 265 - 265
  • [2] MEASUREMENT OF GRIP STRENGTH - VALIDITY AND RELIABILITY OF THE SPHYGMOMANOMETER AND JAMAR GRIP DYNAMOMETER
    HAMILTON, GF
    MCDONALD, C
    CHENIER, TC
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 215 - 219
  • [3] Reliability and validity of the Grip-Ball dynamometer for grip-strength measurement
    Chkeir, Aly
    Jaber, Rana
    Hewson, David J.
    Duchene, Jacques
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1996 - 1999
  • [4] RELIABILITY OF GRIP STRENGTH ASSESSMENT WITH THE COMPUTERIZED JAMAR DYNAMOMETER
    NIEBUHR, BR
    MARION, R
    FIKE, ML
    OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1994, 14 (01): : 3 - 18
  • [5] Concurrent Validity and Reliability of a Handheld Dynamometer in Measuring Isometric Shoulder Rotational Strength
    Chen, Bin
    Liu, Lifen
    Chen, Lincoln Bin
    Cao, Xianxin
    Han, Peng
    Wang, Chenhao
    Qi, Qi
    JOURNAL OF SPORT REHABILITATION, 2021, 30 (06) : 965 - 968
  • [6] Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength
    Sartorio, Francesco
    Lippi, Lorenzo
    Vercelli, Stefano
    Gallo, Federica
    Zanin, Davide
    Bergesio, Sara
    de Sire, Alessandro
    Invernizzi, Marco
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [7] Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity
    Johansson, Fredrik R.
    Skillgate, Eva
    Lapauw, Mattis L.
    Clijmans, Dorien
    Deneulin, Valentijn P.
    Palmans, Tanneke
    Cools, Ann M.
    JOURNAL OF ATHLETIC TRAINING, 2015, 50 (07) : 719 - 725
  • [8] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [9] Study of Reliability and Validity of the Load Cell-Type Hand Dynamometer Compared to the Jamar Dynamometer and the Number of Reliable Grip Strength Measurements
    Kanauchi, Yumiko
    Murase, Tsuyoshi
    Nishiwaki, Masao
    Odagiri, Masahiro
    Wanezaki, Yoshihiro
    Ishikawa, Hitoshi
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (05): : 562 - 572
  • [10] Measuring Grip Strength in Older Adults: Comparing the Grip-ball With the Jamar Dynamometer
    Vermeulen, Joan
    Neyens, Jacques C. L.
    Spreeuwenberg, Marieke D.
    van Rossum, Erik
    Hewson, David J.
    de Witte, Luc P.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2015, 38 (03) : 148 - 153