CONTRAST-SENSITIVITY LOSS IN A GROUP OF FORMER MICROELECTRONICS WORKERS WITH NORMAL VISUAL-ACUITY

被引:38
|
作者
FRENETTE, B [1 ]
MERGLER, D [1 ]
BOWLER, R [1 ]
机构
[1] UNIV QUEBEC,CTR ETUD INTERACT BIOL ENTRE SANTE & ENVIRONM,CP 8888,SUCC A,MONTREAL H3C 3P8,QUEBEC,CANADA
关键词
MICROELECTRONICS; CONTRAST SENSITIVITY; VISUAL ACUITY; ORGANIC SOLVENTS;
D O I
10.1097/00006324-199107000-00009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The measurement of contrast sensitivity at varying grating frequencies is used increasingly to study visual and neural disorders. It provides more information than conventional acuity measures. Refractive errors initially affect high spatial frequencies, whereas lower spatial frequencies are affected only when these errors are pronounced. Neurophysiological alterations are reflected by depressed sensitivity to coarse gratings. Visual dysfunction has been associated with workplace exposures to a wide range of organic solvents. In microelectronics assembly where large quantities of organic solvents are used in many aspects of the work processes, visual deficits have been observed. The objective of the present study was to compare contrast sensitivity among former microelectronics assembly workers, with normal far and near visual acuity, and a reference group from the same region, with similar acuity. No significant differences were observed between scores at the two ends of the contrast sensitivity curves; however, at the intermediate spatial frequencies, the former microelectronics workers' scores were significantly lower (Student's t-test; p < 0.05). For the microelectronics workers, no relation was observed between age and contrast sensitivity at any spatial frequency, whereas for the reference group, contrast sensitivity scores were progressively lower with age at spatial frequencies greater-than-or-equal-to 6.0 cpd (r2 = 0.15 at 6 cpd to r2 = 0.45 at 18.0 cpd), suggesting that for the former there is some form of interference with the expected contrast sensitivity loss with age. Lower contrast sensitivity scores in intermediate spatial frequencies, observed among the former microelectronics workers, possible reflect neural alterations, which may have resulted from exposure to neurotoxic substances. These findings suggest the need for further studies on visual functions in microelectronics workers.
引用
收藏
页码:556 / 560
页数:5
相关论文
共 50 条
  • [1] VISUAL-ACUITY AND CONTRAST SENSITIVITY IN THE ELDERLY
    HIRVELA, H
    KOSKELA, P
    LAATIKAINEN, L
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1995, 73 (02): : 111 - 115
  • [2] LUMINANCE EFFECTS ON VISUAL-ACUITY AND SMALL LETTER CONTRAST SENSITIVITY
    RABIN, J
    OPTOMETRY AND VISION SCIENCE, 1994, 71 (11) : 685 - 688
  • [3] VISUAL-ACUITY VS LETTER CONTRAST SENSITIVITY IN RETINITIS-PIGMENTOSA
    ALEXANDER, KR
    DERLACKI, DJ
    FISHMAN, GA
    VISION RESEARCH, 1995, 35 (10) : 1495 - 1499
  • [4] VISUAL-ACUITY AND CONTRAST SENSITIVITY OF THE S-CONE PATHWAY - PRELIMINARY MEASURES WITH LETTER CHARTS
    RABIN, J
    ADAMS, AJ
    OPTOMETRY AND VISION SCIENCE, 1990, 67 (11) : 799 - 802
  • [5] CONTRAST SENSITIVITY EVALUATION IN EYES PREDISPOSED TO AGE-RELATED MACULAR DEGENERATION AND PRESENTING NORMAL VISUAL-ACUITY
    STANGOS, N
    VOUTAS, S
    TOPOUZIS, F
    KARAMPATAKIS, V
    OPHTHALMOLOGICA, 1995, 209 (04) : 194 - 198
  • [6] DYNAMIC VISUAL-ACUITY AND CONTRAST SENSITIVITY FOR STATIC AND FLICKERED GRATINGS IN A COLLEGE SAMPLE
    LONG, GM
    MAY, PA
    OPTOMETRY AND VISION SCIENCE, 1992, 69 (12) : 915 - 922
  • [7] A NEW SET OF VARIABLE-CONTRAST VISUAL-ACUITY CHARTS
    WANG, GJ
    POMERANTZEFF, O
    OPTOMETRY AND VISION SCIENCE, 1991, 68 (01) : 34 - 40
  • [8] INFLUENCE OF TYPE AND SEVERITY OF PURE FORMS OF AGE-RELATED CATARACT ON VISUAL-ACUITY AND CONTRAST SENSITIVITY
    MARAINI, G
    ROSMINI, F
    GRAZIOSI, P
    TOMBA, MC
    BONACINI, M
    COTICHINI, R
    PASQUINI, P
    SPERDUTO, RD
    MILTON, R
    BATTAINI, C
    BELPOLITI, M
    WILLIAMS, SL
    CORONA, RM
    CRATERI, RS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (01) : 262 - 267
  • [9] COMPARATIVE FUNCTIONAL RESULTS (CONTRAST SENSITIVITY AND DYNAMIC VISUAL-ACUITY) OF MULTIFOCAL AND MONOFOCAL IMPLANTS
    POIRIER, L
    WILLIAMSON, W
    COULON, P
    LAGOUTTE, F
    VERIN, P
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1992, 15 (8-9): : 478 - 482
  • [10] COMPARISON OF PREOPERATIVE 10-HZ VISUAL EVOKED-POTENTIALS TO CONTRAST SENSITIVITY AND VISUAL-ACUITY AFTER CATARACT-EXTRACTION
    CAVENDER, SA
    HOBSON, RR
    CHAO, GM
    WEINSTEIN, GW
    ODOM, JV
    DOCUMENTA OPHTHALMOLOGICA, 1992, 81 (02) : 181 - 188