VALUE OF WASHINGS AND BRUSHINGS AT FIBEROPTIC BRONCHOSCOPY IN THE DIAGNOSIS OF LUNG-CANCER

被引:92
作者
MAK, VHF
JOHNSTON, IDA
HETZEL, MR
GRUBB, C
机构
[1] JOINT UNIV COLL HOSP LONDON,LONDON,ENGLAND
[2] ROYAL FREE HOSP,DEPT CYTOL,LONDON,ENGLAND
[3] NATL TEMPERENCE HOSP,LONDON,ENGLAND
[4] WHITTINGTON HOSP,DEPT RESP MED,LONDON N19 5NF,ENGLAND
关键词
D O I
10.1136/thx.45.5.373
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
A retrospective study was performed to evaluate the diagnostic yield for lung cancer from histological biopsy specimens and from washings and brushings for cytological examination taken at fibreoptic bronchoscopy. The records of 680 bronchoscopies were analysed. Of 300 patients eventually diagnosed as having a malignant lesion, 188 had had biopsy, washing, and brushing. Of these, 125 had endoscopically visible tumour (group A) and 63 had no abnormal findings pr abnormal findings that were not diagnostic of malignancy (group B). In group A biopsy specimens gave a positive result in 76% of cases, washings in 49.6%, and brushings in 52%; biopsy material gave the only positive result in 22.4% of cases, washings in 2.2%, and brushings in 4.8%. In group B biopsy specimens were positive in 36.5%, washings in 38.1%, and brushings in 28.6%; biopsy gave the only positive result in 11.1% of cases, washing in 9.5%, and brushing in 3.2%. Washing had a higher diagnostic yield than brushing in group B. Biopsy and cytological examination of either washings or brushings were found to give over 95% of all positive results in group A, but in group B the combination of biopsy and washing was more often successful (94.3%) than biopsy and brushing (82.8%). It is concluded that for the maximum diagnostic yield in the diagnosis of lung cancer biopsy should be combined with cytology using both washings and brushings.
引用
收藏
页码:373 / 376
页数:4
相关论文
共 9 条
  • [1] CHAUDHARY BA, 1978, J THORAC CARDIOV SUR, V76, P33
  • [2] FIBEROPTIC BRONCHOSCOPY - EFFECT OF MULTIPLE BRONCHIAL BIOPSIES ON DIAGNOSTIC YIELD IN BRONCHIAL-CARCINOMA
    GELLERT, AR
    RUDD, RM
    SINHA, G
    GEDDES, DM
    [J]. THORAX, 1982, 37 (09) : 684 - 687
  • [3] DIAGNOSTIC ACCURACY IN LUNG-CANCER - COMPARISON OF TECHNIQUES USED IN ASSOCIATION WITH FLEXIBLE FIBEROPTIC BRONCHOSCOPY
    KVALE, PA
    BODE, FR
    KINI, S
    [J]. CHEST, 1976, 69 (06) : 752 - 757
  • [4] LAM WK, 1983, CLIN ONCOL, V9, P35
  • [5] DIAGNOSTIC-ACCURACY OF MULTIPLE BIOPSIES FROM FLEXIBLE FIBEROPTIC BRONCHOSCOPY - A COMPARISON OF CENTRAL VERSUS PERIPHERAL CARCINOMA
    POPOVICH, J
    KVALE, PA
    EICHENHORN, MS
    RADKE, JR
    OHORODNIK, JM
    FINE, G
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 125 (05): : 521 - 523
  • [6] RICHARDSON RH, 1974, AM REV RESPIR DIS, V109, P63
  • [7] CYTOLOGY IN FIBEROPTIC BRONCHOSCOPY - COMPARISON OF BRONCHIAL BRUSHING, WASHING AND POST-BRONCHOSCOPY SPUTUM
    SOLOMON, DA
    SOLLIDAY, NH
    GRACEY, DR
    [J]. CHEST, 1974, 65 (06) : 616 - 619
  • [8] EFFECT OF TUMOR SIZE AND LOCATION ON DIAGNOSIS BY FIBEROPTIC BRONCHOSCOPY
    STRINGFIELD, JT
    MARKOWITZ, DJ
    BENTZ, RR
    WELCH, MH
    WEG, JG
    [J]. CHEST, 1977, 72 (04) : 474 - 476
  • [9] USE OF BRONCHOFIBERSCOPE FOR BRONCHIAL BRUSH BIOPSY - DIAGNOSTIC RESULTS AND COMPARISON WITH OTHER BRUSHING TECHNIQUES
    ZAVALA, DC
    RICHARDS.RH
    MUKERJEE, PK
    ROSSI, NP
    BEDELL, GN
    [J]. CHEST, 1973, 63 (06) : 889 - 892