METHOD OF TRANSFERRING SIZE OF UNIT OF ABSORBED DOSE INTENSITY FROM STATE PRIMARY STANDARD TO A STANDARD FACILITY FOR MEASURING ABSORBED DOSE OF GAMMA-RADIATION FROM CO-60 IN MUSCLE-TISSUE

被引:0
|
作者
BREGADZE, YI
MURATOV, NI
TULTAEV, AV
机构
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
引用
收藏
页码:444 / 446
页数:3
相关论文
共 17 条
  • [1] THE GRAPHITE CALORIMETER AS A STANDARD OF ABSORBED DOSE FOR CO-60 GAMMA-RADIATION
    PRUITT, JS
    DOMEN, SR
    LOEVINGER, R
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1981, 86 (05): : 495 - 502
  • [2] Graphite ionization chamber as an ionometric standard of absorbed dose to water for Co-60 radiation
    Szymko, M. M.
    Knyziak, A. B.
    Derlacinski, M.
    MEASUREMENT, 2022, 194
  • [3] State Primary Standard of the Unit of Absorbed Dose and Unit of Absorbed Dose Rate of Beta Radiation in Tissue-Equivalent Material Get 9-2018
    S. A. Fedina
    A. V. Oborin
    A. Yu. Villevalde
    E. N. Rumyantseva
    S. G. Trofimchuk
    Measurement Techniques, 2019, 62 : 579 - 586
  • [4] State Primary Standard of the Unit of Absorbed Dose and Unit of Absorbed Dose Rate of Beta Radiation in Tissue-Equivalent Material Get 9-2018
    Fedina, S. A.
    Oborin, A., V
    Villevalde, A. Yu
    Rumyantseva, E. N.
    Trofimchuk, S. G.
    MEASUREMENT TECHNIQUES, 2019, 62 (07) : 579 - 586
  • [5] DETERMINING THE ENERGY-SPECTRUM OF THE GAMMA-RADIATION FROM A WORKING STANDARD FOR THE UNITS OF POWER OF ABSORBED DOSE OF PHOTON RADIATION
    ALEIKIN, VV
    BERLYAND, VA
    GENERALOVA, VV
    TIKHONOV, EG
    MEASUREMENT TECHNIQUES, 1980, 23 (08) : 768 - 771
  • [6] STATE PRIMARY STANDARD FOR UNIT OF EXPOSED DOSE OF X-RAY AND GAMMA-RADIATION
    YUDIN, MF
    KOCHINA, MP
    OSTROMUKHOVA, GP
    KONONOVA, RF
    MEASUREMENT TECHNIQUES-USSR, 1972, 15 (02): : 185 - +
  • [7] Traceability of absorbed dose in photon radiation therapy: from primary standard to patient treatment
    de Carlan, Loic
    Baltes, Didier
    Bordy, Jean-Marc
    Daures, Josiane
    Delaunay, Frank
    Ostrowsky, Aime
    Sorel, Soizic
    ACCREDITATION AND QUALITY ASSURANCE, 2009, 14 (11) : 613 - 618
  • [8] Traceability of absorbed dose in photon radiation therapy: from primary standard to patient treatment
    Loïc de Carlan
    Didier Baltès
    Jean-Marc Bordy
    Josiane Daures
    Frank Delaunay
    Aimé Ostrowsky
    Soizic Sorel
    Accreditation and Quality Assurance, 2009, 14 : 613 - 618
  • [10] SPECIAL STATE STANDARD OF ABSORBED DOSE UNIT OF X-RAY-RADIATION WITH MAXIMUM PHOTON ENERGY FROM 3 TO 9 FJ (20-60 KEV)
    KONONOVA, RF
    SEBEKIN, AP
    FOMINYKH, VI
    YUDIN, MF
    MEASUREMENT TECHNIQUES, 1976, 19 (03) : 409 - 411