CALIBRATION OF RF FIELD-STRENGTH METERS

被引:6
|
作者
DEVREEDE, JPM
TEUNISSE, GM
MUNTER, K
HOITINK, H
HOLLAND, K
ODWYER, M
BERGSTEN, L
PURANEN, L
机构
[1] PHYS TECH BUNDESANSTALT,D-38023 BRAUNSCHWEIG,GERMANY
[2] ABB RES CTR,EMC BADEN LTD,CH-5405 BADEN DATWILL,SWITZERLAND
[3] NATL PHYS LAB,TEDDINGTON TW11 0LW,MIDDX,ENGLAND
[4] RADIO FREQUENCY TECHNOL,DUBLIN 8,IRELAND
[5] SWEDISH NATL TESTING & RES INST,S-50115 BORAS,SWEDEN
[6] FINNISH CTR RADIAT & NUCL SAFETY,SF-00881 HELSINKI,FINLAND
关键词
D O I
10.1109/19.377850
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An intercomparison of field strength meters was performed during 1991-1993 over the frequency range 100 kHz-1000 MHz and field strength range 1-10 V/m using different calibration techniques. Four field sensors, electric as well as magnetic, have been used. Seven institutes participated in this intercomparison using at least three different calibration methods. A calibration uncertainty of less than 1 dB can be obtained if certain procedures are followed. The results are applicable in the fields of EMC testing and health care (nonionizing radiation).
引用
收藏
页码:351 / 354
页数:4
相关论文
共 50 条
  • [1] ANALYSIS OF CALIBRATION ARRANGEMENTS FOR AC FIELD-STRENGTH METERS
    TAKUMA, T
    KAWAMOTO, T
    SUNAGA, Y
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (02): : 489 - 496
  • [2] LEARNING TO USE FIELD-STRENGTH METERS
    DEMAW, D
    QST, 1985, 69 (03) : 26 - 30
  • [3] APPLICATION OF THERMISTORS IN REFERENCE FIELD-STRENGTH METERS WITH DIPOLE ANTENNAS
    BUZINOV, VS
    TISHCHENKO, VA
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (04): : 343 - 344
  • [4] CHARACTERISTICS OF BROAD-BAND RADIOFREQUENCY FIELD-STRENGTH METERS
    MANTIPLY, ED
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 889 - 891
  • [6] Antenna field calibration laboratory for RF electromagnetic field meters
    Marinescu, A
    Scornea, A
    Dumbrava, I
    Mihai, G
    Glimm, J
    Münter, K
    Pape, R
    2003 IEEE International Symposium on Electromagnetic Compatibility (EMC), Vols 1 and 2, Symposium Record, 2003, : 112 - 114
  • [7] PULSE TECHNIQUES FOR CALIBRATION OF THE DECOUPLER RADIOFREQUENCY FIELD-STRENGTH
    NIELSEN, NC
    BILDSOE, H
    JAKOBSEN, HJ
    SORENSEN, OW
    JOURNAL OF MAGNETIC RESONANCE, 1986, 66 (03) : 456 - 469
  • [8] 2 STANDARD FIELD-STRENGTH METERS FOR VERY-HIGH FREQUENCIES
    KING, DD
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1950, 38 (09): : 1048 - 1051
  • [9] MEASUREMENT OF FIELD-STRENGTH AND CALIBRATION OF ANTENNAS AT LOW-FREQUENCIES
    TISHCHENKO, VA
    TOKATLY, VI
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (03): : 260 - 261
  • [10] Characteristics, calibration and measurement uncertainty of RF field strength meters in the frequency range up to 18 GHz
    Pape, R.
    Muenter, K.
    Schrader, T.
    ADVANCES IN RADIO SCIENCE, 2007, 5 (435-438) : 435 - 438