THE PRODUCTION OF XE-127 VIA (NAT)XE(P,XN)CS-127-]XE-127

被引:1
|
作者
NORTIER, FM
MILLS, SJ
STEYN, GF
机构
[1] National Accelerator Centre, Faure, 7131
关键词
D O I
10.1016/0969-8043(93)90106-K
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Effective cross-sections for the production of Cs-127 in the bombardment of (nat)Xe with protons were measured from threshold up to 100 MeV. From the integral excitation function obtained, yield curves for Xe-127, produced via the (nat)Xe(p,xn)Cs-127 --> Xe-127 route, were derived for a full range of ps target thicknesses. These curves can be used for the optimization of the production of Xe-127 within specific practical incident energy and target thickness constraints. The expected optimum yield for a representative production gas target (1.64 g/cm2 thick) is 6.7 MBq/muAh (obtained at an incident energy of 39.3 MeV).
引用
收藏
页码:1494 / 1496
页数:3
相关论文
共 50 条
  • [41] PROCESSING OF XE-127 REGIONAL PULMONARY VENTILATION BY FACTOR-ANALYSIS AND COMPARTMENTAL MODELING
    CINOTTI, L
    BAZIN, JP
    SUSSKIND, H
    BRILL, AB
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 437 - 444
  • [42] A COMPARISON OF XE-133 AND XE-127 FOR THE DETERMINATION OF REGIONAL CEREBRAL BLOOD-FLOW MEASURED BY DYNAMIC SPECT
    COPPOLA, R
    MARENCO, S
    JONES, DW
    BERMAN, KF
    WEINBERGER, DR
    PSYCHIATRY RESEARCH-NEUROIMAGING, 1992, 45 (03) : 187 - 200
  • [43] LOW-LYING STATES IN XE-127 - IMPLICATIONS FOR THE EFFICIENCY OF AN I-127 SOLAR NU-DETECTOR
    GARCIA, A
    ADELBERGER, EG
    CHARLOP, A
    GIL, S
    GUNDLACH, JH
    KAILAS, S
    PHYSICAL REVIEW C, 1990, 41 (02): : 775 - 777
  • [44] ECONOMICS OF XE-127, XE-133 AND KRYPTON 81M FOR ROUTINE VENTILATION IMAGING OF THE LUNGS - REPLY
    NIMMO, MJ
    MERRICK, MV
    MILLAR, AM
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (699): : 298 - 299
  • [45] A COMPARISON OF THE ECONOMICS OF XE-127, XE-133 AND KRYPTON-81M FOR ROUTINE VENTILATION IMAGING OF THE LUNGS
    NIMMO, MJ
    MERRICK, MV
    MILLAR, AM
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (691): : 635 - 636
  • [46] ASSESSMENT OF PULMONARY VENTILATION SCANS USING XE-127 IN THE DIAGNOSIS OF PULMONARY-EMBOLISM
    ROWE, IF
    SLEIGHT, PJ
    GAUNT, JI
    CROFT, DN
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (04): : 154 - 156
  • [47] A NEW METHOD OF IMAGING THE RIGHT VENTRICLE USING PERIPHERAL VEIN INFUSION OF XE-127
    RODRIGUES, EA
    LAHIRI, A
    HINGE, DA
    SMITH, T
    CRAWLEY, JCW
    RAFTERY, EB
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1987, 12 (12): : 617 - 619
  • [48] XE-127 FOR VENTILATION SCAN - AN ECONOMICAL AID TO EMERGENCY DIAGNOSIS OF PULMONARY-EMBOLISM
    MULLERBRAND, J
    FRIDRICH, R
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1984, 114 (48) : 1741 - 1743
  • [49] SIMPLE DEVICE FOR EFFICIENT TRANSFER AND UNIT DOSE PACKAGING OF XE-127 - CONCISE COMMUNICATION
    KOWALSKY, RJ
    DALTON, DR
    SAYLOR, WL
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (04) : 414 - 418
  • [50] ABSOLUTE GAMMA-RAY INTENSITIES IN DECAY OF KR-79 AND XE-127
    COLLE, R
    KISHORE, R
    PHYSICAL REVIEW C, 1974, 9 (03): : 981 - 987