Effective cross-sections for the production of Cs-127 in the bombardment of (nat)Xe with protons were measured from threshold up to 100 MeV. From the integral excitation function obtained, yield curves for Xe-127, produced via the (nat)Xe(p,xn)Cs-127 --> Xe-127 route, were derived for a full range of ps target thicknesses. These curves can be used for the optimization of the production of Xe-127 within specific practical incident energy and target thickness constraints. The expected optimum yield for a representative production gas target (1.64 g/cm2 thick) is 6.7 MBq/muAh (obtained at an incident energy of 39.3 MeV).
引用
收藏
页码:1494 / 1496
页数:3
相关论文
共 50 条
  • [31] COMPARISON OF XE-127 AND XE-133 IN VENTILATION-PERFUSION IMAGING IN DIAGNOSIS OF PULMONARY EMBOLUS
    MCCARTNEY, WH
    PERRY, JR
    STAAB, EV
    PARKER, LA
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 675 - 675
  • [32] IN-BEAM STUDY OF XE-127,XE-129 AND COLLECTIVE DESCRIPTION OF THE LEVEL STRUCTURES IN ODD-A XE NUCLEI
    HELPPI, H
    HATTULA, J
    LUUKKO, A
    JAASKELAINEN, M
    NUCLEAR PHYSICS A, 1981, 357 (02) : 333 - 355
  • [33] WEAK-COUPLING IN THE ODD-MASS XE NUCLIDES - DECAY OF 6.2-H CS-127 TO LEVELS OF ODD-NEUTRON XE-127
    MANTICA, PF
    ZIMMERMAN, BE
    WALTERS, WB
    CARTER, HK
    RUPNIK, D
    ZGANJAR, EF
    CROFT, WL
    XU, YS
    PHYSICAL REVIEW C, 1990, 42 (03): : 902 - 921
  • [34] A COMPARISON BETWEEN SUB-MICRONIC AEROSOL AND XE-127 FOR VENTILATION IMAGES
    COATES, G
    DOLOVICH, M
    NEWHOUSE, MT
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P113 - P113
  • [35] GAMMA-GAMMA DIRECTIONAL CORRELATION IN DECAY OF XE-125 AND XE-127 AT HIGH GAS DENSITY
    LEDEBUR, TV
    EICHLER, R
    HELVETICA PHYSICA ACTA, 1973, 46 (01): : 50 - 51
  • [36] XENON-133, XE-127, AND XE-125 FOR LUNG-FUNCTION INVESTIGATIONS - A DOSIMETRIC COMPARISON
    GODDARD, BA
    ACKERY, DM
    JOURNAL OF NUCLEAR MEDICINE, 1975, 16 (08) : 780 - 786
  • [37] REGIONAL PULMONARY CLEARANCE OF XE-127 COMPARED WITH N-13 IN MAN
    JONES, HA
    EISER, NM
    HERRING, A
    HUGHES, JMB
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1976, 12 (06): : P200 - P200
  • [38] DIRECT MEASUREMENT OF XE-127 ACTIVITY WITH A 4-PI-GAMMA-DETECTOR
    VATIN, R
    CHAUVENET, B
    APPLIED RADIATION AND ISOTOPES, 1987, 38 (10) : 767 - 770
  • [39] ECONOMICS OF XE-127, XE-133 AND KRYPTON-81M FOR ROUTINE VENTILATION IMAGING OF THE LUNGS
    FINN, JP
    LAVENDER, JP
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (705): : 959 - 959
  • [40] Comparison of imaging characteristics of Xe-133 and Xe-127 for use in dynamic brain SPECT: A Monte Carlo investigation
    Pretorius, PH
    Glick, SJ
    De Vries, DJ
    Licho, R
    King, MA
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1005 - 1008