EFFECT OF BUNDLE ORIENTATION ON TRANSMISSION-LINE AUDIBLE AND RADIO NOISE

被引:8
作者
CHARTIER, VL [1 ]
BLAIR, DE [1 ]
STEARNS, RD [1 ]
LAMB, DJ [1 ]
机构
[1] BONNEVILLE POWER ADM,DIV ELECT ELECTR ENGN,PORTLAND,OR 97208
关键词
CORONA; AUDIBLE NOISE; RADIO NOISE; TRANSMISSION LINES; BUNDLE ORIENTATION;
D O I
10.1109/61.311213
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A bundle of four conductors may be used for the next generation of 500-kV fines at the Bonneville Power Administration (BPA). Among the many questions that needed answers were (a) the optimal orientation of the bundle to minimize the audible (AN) and radio noise (RI) and (b) whether trapezoidal conductors behaved differently than conventional stranded conductors. This paper shows the results of comparative tests conducted in BPA's high voltage laboratory comparing the RI and AN from 4 Bunting (conventional round rod) and 4 Hood (trapezoidal) conductors oriented either in a square or a diamond configuration. To make the results more useful, similar tests were conducted on 2 Bunting and 2 Hood conductors oriented either horizontally or vertically and on 3 Bunting and 3 Hood conductors oriented in a vee or an inverted vee configuration. Tests on single Bunting and Hood conductors were also conducted. The tests showed that within the accuracy of noise measurements bundle orientation has little effect on the AN or RI and that the conventional Bunting and the trapezoidal Hood conductors have essentially the same noise performance.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [21] Calculation model for the propagation of audible noise from high voltage transmission lines
    Li, Xuebao
    Cui, Xiang
    Lu, Tiebing
    He, Jiamei
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (08): : 2045 - 2052
  • [22] Calculation and Analysis of Audible Noise of Transmission Lines in the Crossing Area
    Xie, Gonghao
    He, Wangling
    Fu, Wanzhang
    Lan, Lei
    Zhu, Changcheng
    Deng, Yeqiang
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [23] NEW METHOD FOR TAPERED TRANSMISSION-LINE DESIGN
    WANG, Y
    ELECTRONICS LETTERS, 1991, 27 (25) : 2396 - 2398
  • [24] AN IMPROVEMENT TO THE TRANSMISSION-LINE MODEL OF THE FOLDED DIPOLE
    CLARK, AR
    FOURIE, APC
    IEE PROCEEDINGS-H MICROWAVES ANTENNAS AND PROPAGATION, 1991, 138 (06) : 577 - 579
  • [25] Statistical Evaluation and Prediction of Audible Noise of HVDC Transmission Lines
    Yi, Yong
    Chen, Zhengying
    Wang, Liming
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 279 - 282
  • [26] STATISTICAL AUDIBLE NOISE PERFORMANCE OF SHIOBARA HVDC TEST LINE
    NAKANO, Y
    FUKUSHIMA, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (01) : 290 - 296
  • [27] Altitude Correction Method for Audible Noise of ± 800 kV UHVdc Overhead Transmission Line and its Engineering Application
    Zhao, Luxing
    Xie, Li
    Wang, Dafei
    He, Kun
    Gao, Lei
    Ju, Yong
    Lu, Jiayu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (05) : 3375 - 3386
  • [28] A REVIEW OF DYNAMIC ASPECTS OF TRANSMISSION-LINE DESIGN
    SMITH, BW
    ENGINEERING STRUCTURES, 1993, 15 (04) : 271 - 275
  • [29] Outdoor Investigation of the Corona Characteristics and Audible Noise of a Hybrid AC/DC Overhead Line
    Hedtke, S.
    Bleuler, P.
    Franck, C. M.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (06) : 3309 - 3317
  • [30] Research Progress on Audible Noise Emitted from HVDC Transmission Lines
    Li, Li
    Meng, Wei
    Li, Qi
    Wang, Yifan
    Zheng, Xiaoguang
    Wang, Hongbin
    ENERGIES, 2023, 16 (12)