EFFECT OF BUNDLE ORIENTATION ON TRANSMISSION-LINE AUDIBLE AND RADIO NOISE

被引:8
|
作者
CHARTIER, VL [1 ]
BLAIR, DE [1 ]
STEARNS, RD [1 ]
LAMB, DJ [1 ]
机构
[1] BONNEVILLE POWER ADM,DIV ELECT ELECTR ENGN,PORTLAND,OR 97208
关键词
CORONA; AUDIBLE NOISE; RADIO NOISE; TRANSMISSION LINES; BUNDLE ORIENTATION;
D O I
10.1109/61.311213
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A bundle of four conductors may be used for the next generation of 500-kV fines at the Bonneville Power Administration (BPA). Among the many questions that needed answers were (a) the optimal orientation of the bundle to minimize the audible (AN) and radio noise (RI) and (b) whether trapezoidal conductors behaved differently than conventional stranded conductors. This paper shows the results of comparative tests conducted in BPA's high voltage laboratory comparing the RI and AN from 4 Bunting (conventional round rod) and 4 Hood (trapezoidal) conductors oriented either in a square or a diamond configuration. To make the results more useful, similar tests were conducted on 2 Bunting and 2 Hood conductors oriented either horizontally or vertically and on 3 Bunting and 3 Hood conductors oriented in a vee or an inverted vee configuration. Tests on single Bunting and Hood conductors were also conducted. The tests showed that within the accuracy of noise measurements bundle orientation has little effect on the AN or RI and that the conventional Bunting and the trapezoidal Hood conductors have essentially the same noise performance.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [1] RESULTS FROM AC TRANSMISSION-LINE AUDIBLE NOISE STUDIES AT THE ANNEBERG EHV TEST STATION
    LUNDQUIST, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (01) : 317 - 323
  • [2] Extract Study of Transmission Line Audible Noise
    Wu Fa-yuan
    Zhou Jin-quan
    Liu Sheng-nan
    Dai Xiao-min
    Liu Ping
    Cai Jun
    2018 3RD INTERNATIONAL CONFERENCE ON SMART CITY AND SYSTEMS ENGINEERING (ICSCSE), 2018, : 439 - 442
  • [3] Radio and audible noise performance of T2 conductors
    Chartier, VL
    Lowder, SM
    Rodick, S
    Vogt, MW
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1464 - 1474
  • [4] Computation of Audible Noise from a 1200 kV UHV Power Transmission Line
    Kumar, K. Bharath
    Thomas, M. Joy
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (02) : 974 - 978
  • [5] Audible noise of transmission lines caused by the corona effect: Analysis, modelling, prediction
    Engel, Z
    Wszolek, T
    APPLIED ACOUSTICS, 1996, 47 (02) : 149 - 163
  • [6] Comparative study on corona-generated audible noise and radio noise of ac long-term operating conductors with two bundle types
    Bian, Xingming
    Chen, Lan
    Zhao, Xuesong
    Chen, Fangdong
    Ji, Jianfei
    Wan, Shuwei
    Wang, Liming
    JOURNAL OF ELECTROSTATICS, 2015, 74 : 47 - 55
  • [7] The Altitude Effect and Correction of Audible Noise for HVdc Transmission Lines
    Zhao, Luxing
    Lu, Jiayu
    Cui, Xiang
    Xie, Li
    Ju, Yong
    He, Kun
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (04) : 1954 - 1963
  • [8] Audible Noise Calculation for Different Overhead Transmission Lines
    Kurniawan, Indra
    Suwarno
    Pischler, Oliver
    Schichler, Uwe
    2018 53RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2018,
  • [9] THE TRANSMISSION-LINE VACUUM
    GRAY, RI
    PHYSICS ESSAYS, 1995, 8 (03) : 285 - 298
  • [10] TRANSMISSION-LINE TRANSFORMER
    CARVALHO, MCR
    MARGULIS, W
    ELECTRONICS LETTERS, 1991, 27 (02) : 138 - 139