DETERMINATION OF THE HOLD-UP TIME AND COLUMN OUTLET DENSITY FOR CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY

被引:6
|
作者
RIESTER, RL [1 ]
YAN, C [1 ]
MARTIRE, DE [1 ]
机构
[1] GEORGETOWN UNIV,DEPT CHEM,WASHINGTON,DC 20057
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 588卷 / 1-2期
基金
美国国家科学基金会;
关键词
D O I
10.1016/0021-9673(91)85035-E
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The column hold-up time (t(u)) was determined for a capillary supercritical fluid chromatographic system over a range of temperatures and densities using methane as a marker and using homologous series extrapolations. At low temperatures, t(u) was found to pass through a maximum with increasing density. To establish that this phenomenon is not due to a retention effect, t(u) was also calculated from flow-rate measurements. The measured hold-up times and Darcy's law were used to calculate the outlet densities for different inlet pressures at two temperatures.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [1] Determination of the column hold-up volume in supercritical fluid chromatography using nitrous-oxide
    Vajda, Peter
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1309 : 96 - 100
  • [2] Exploring the application limits of different hold-up time markers in supercritical fluid chromatography
    Csanád Rédei
    Alessandro Buratti
    Martina Catani
    Attila Felinger
    Analytical and Bioanalytical Chemistry, 2024, 416 : 1485 - 1492
  • [3] Exploring the application limits of different hold-up time markers in supercritical fluid chromatography
    Redei, Csanad
    Buratti, Alessandro
    Catani, Martina
    Felinger, Attila
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (06) : 1485 - 1492
  • [4] ON THE DETERMINATION OF THE HOLD-UP TIME IN REVERSED PHASE LIQUID-CHROMATOGRAPHY
    BERENDSEN, GE
    SCHOENMAKERS, PJ
    GALAN, LD
    VIGH, G
    VARGAPUCHONY, Z
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (11): : 1669 - 1686
  • [5] DUAL CAPILLARY COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY
    RAYNOR, MW
    MOULDER, R
    DAVIES, IL
    KITHINJI, JP
    CLIFFORD, AA
    BARTLE, KD
    HALL, JE
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1990, 13 (01): : 22 - 26
  • [6] On the determination of the hold-up volume by liquid chromatography columns
    Eltekova, NA
    Eltekov, YA
    ZHURNAL FIZICHESKOI KHIMII, 1996, 70 (10): : 1884 - 1887
  • [7] SIMPLE RESTRICTORS FOR CAPILLARY COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY
    GREEN, S
    BERTSCH, W
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (05): : 414 - 415
  • [8] Microelectrochemical detection in capillary column supercritical fluid chromatography
    Wallenborg, SR
    Markides, KE
    Nyholm, L
    PROCEEDINGS OF THE SYMPOSIUM ON CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL ELECTROCHEMICAL METHODS, 1997, 97 (19): : 665 - 673
  • [9] DENSITY PROGRAMMING IN CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    FJELDSTED, JC
    JACKSON, WP
    PEADEN, PA
    LEE, ML
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (05) : 222 - 225
  • [10] THEORETICAL CALCULATION OF GAS HOLD-UP TIME IN CAPILLARY GAS-CHROMATOGRAPHY - INFLUENCE OF COLUMN, INSTRUMENT PARAMETERS AND ANALYSIS CONDITIONS AND COMPARISON OF DIFFERENT METHODS OF DEAD-TIME DETERMINATION
    CASTELLO, G
    VEZZANI, S
    MORETTI, P
    JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (01) : 95 - 106