COMPARISON OF NAL(TL), CDTE, AND HGL2 SURGICAL PROBES - EFFECT OF SCATTER COMPENSATION ON PROBE PERFORMANCE

被引:10
作者
KWO, DP [1 ]
BARBER, HB [1 ]
BARRETT, HH [1 ]
HICKERNELL, TS [1 ]
机构
[1] UNIV ARIZONA,CTR OPT SCI,TUCSON,AZ 85721
关键词
D O I
10.1118/1.596683
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spatial variation in the background source distribution makes tumor detection difficult for single-detector probes. Using a single energy window that brackets the photopeak helps discriminate against background events dominated by Compton scattering. Another approach is to use the information provided by an additional window in the Compton region. The performances of NaI(T1), CdTe, and HgI2 surgical probes have been compared under realistic simulations of a tumor-staging procedure using optimal single-sided energy windows and a two-window scatter-subtraction technique. Results showed that despite the differences in energy resolution of the detectors, the performances of the probes in a variable background were similar when optimal single energy windows were used. When the background variations were large, using information provided by a second window improved probe performance.
引用
收藏
页码:382 / 389
页数:8
相关论文
共 12 条
[1]   COMPARISON OF NAL(TL), CDTE, AND HGL2 SURGICAL PROBES - PHYSICAL CHARACTERIZATION [J].
BARBER, HB ;
BARRETT, HH ;
HICKERNELL, TS ;
KWO, DP ;
WOOLFENDEN, JM ;
ENTINE, G ;
BACCASH, CO .
MEDICAL PHYSICS, 1991, 18 (03) :373-381
[2]  
BECK RN, 1973, SEMICONDUCTOR DETECT, P88
[3]  
HARVEY WC, 1981, J NUCL MED, V22, P184
[4]   PROBABILITY MODELING OF A SURGICAL PROBE FOR TUMOR-DETECTION [J].
HICKERNELL, TS ;
BARRETT, HH ;
BARBER, HB ;
WOOLFENDEN, JM ;
HALL, JN .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (04) :539-559
[5]  
HICKERNELL TS, 1988, J NUCL MED, V29, P1101
[6]  
JASZCZAK RJ, 1984, J NUCL MED, V25, P893
[7]   DIFFERENTIAL RADIOACTIVITY MONITOR FOR NONINVASIVE DETECTION OF OCULAR MELANOMA [J].
LAMBRECHT, RM ;
PACKER, S ;
ATKINS, HL .
NUCLEAR MEDICINE COMMUNICATIONS, 1984, 5 (06) :381-386
[8]   INTRAOPERATIVE RADIOIMMUNODETECTION OF COLORECTAL TUMOR WITH A HAND-HELD RADIATION DETECTOR [J].
MARTIN, DT ;
HINKLE, GH ;
TUTTLE, S ;
OLSEN, J ;
NABI, H ;
HOUCHENS, D ;
THURSTON, M ;
MARTIN, EW .
AMERICAN JOURNAL OF SURGERY, 1985, 150 (06) :672-675
[9]  
SWETS JA, 1982, EVALUATION DIAGNOSTI, P15
[10]   INTRAOPERATIVE RADIOIMMUNOLOCALIZATION OF COLORECTAL-CARCINOMA WITH A HAND-HELD GAMMA-PROBE AND MAB B72.3 - COMPARISON OF INVIVO GAMMA-PROBE COUNTS WITH INVITRO MAB RADIOLOCALIZATION [J].
TUTTLE, SE ;
JEWELL, SD ;
MOJZISIK, CM ;
HINKLE, GH ;
COLCHER, D ;
SCHLOM, J ;
MARTIN, EW .
INTERNATIONAL JOURNAL OF CANCER, 1988, 42 (03) :352-358