RANDOM SAMPLING FOR EVALUATING TREATMENT PLANS

被引:70
作者
NIEMIERKO, A [1 ]
GOITEIN, M [1 ]
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
dose calculation; mathematical modelling; normal tissue complication probability; random sampling; treatment planning; tumor control probability;
D O I
10.1118/1.596473
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We analyze the influence of sampling technique on the accuracy of estimating irradiated volumes, dose-volume histograms and tumor control and normal tissue complication probabilities. The sampling techniques we consider are uniform distribution of points on a regular Cartesian grid and random selection of points. For three-dimensional treatment planning, random sampling leads to a significant reduction in estimation error and/or in the number of calculation points necessary to achieve a required accuracy. We discuss advantages and drawbacks of random sampling, as compared to sampling on a regular grid. It is suggested that, in practical situations, at least 50 times fewer randomly sampled points per organ/volume of interest are needed for fast estimation of complication probability with the same accuracy, i.e., not exceeding 5% (within 95% confidence limits) in the worst case. © 1990, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:753 / 762
页数:10
相关论文
共 17 条
[1]   RAPID 3-DIMENSIONAL TREATMENT PLANNING .1. RAY-TRACING APPROACH TO PRIMARY COMPONENT DOSE CALCULATIONS [J].
ALTSCHULER, MD ;
SONTAG, MR ;
BLOCH, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (05) :543-556
[2]   3-DIMENSIONAL COMPUTER RECONSTRUCTION FROM SURFACE CONTOURS FOR HEAD CT EXAMINATIONS [J].
BATNITZKY, S ;
PRICE, HI ;
COOK, PN ;
COOK, LT ;
DWYER, SJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (01) :60-67
[3]   DOSE VOLUME HISTOGRAMS IN TREATMENT PLANNING [J].
CHEN, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (06) :1319-1320
[4]  
GROITEIN M, 1987, UNPUB EVALUATION TRE
[5]  
GROITEIN M, 1988, P JOINT US SCANDINAV
[6]   A 3-DIMENSIONAL ELECTRON PENCIL-BEAM ALGORITHM [J].
KOOY, HM ;
RASHID, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (02) :229-243
[7]   LARGE-SCALE OPTIMIZATION OF BEAM WEIGHTS UNDER DOSE-VOLUME RESTRICTIONS [J].
LANGER, M ;
BROWN, R ;
URIE, M ;
LEONG, J ;
STRACHER, M ;
SHAPIRO, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (04) :887-893
[8]  
MYRIANTHOPOULOS L, IN PRESS INT J RAD O
[9]   THE INFLUENCE OF THE SIZE OF THE GRID USED FOR DOSE CALCULATION ON THE ACCURACY OF DOSE ESTIMATION [J].
NIEMIERKO, A ;
GOITEIN, M .
MEDICAL PHYSICS, 1989, 16 (02) :239-247
[10]   THE USE OF VARIABLE GRID SPACING TO ACCELERATE DOSE CALCULATIONS [J].
NIEMIERKO, A ;
GOITEIN, M .
MEDICAL PHYSICS, 1989, 16 (03) :357-366