AREA DETECTOR DESIGN .2. APPLICATION TO A MODULAR CCD-BASED DETECTOR FOR X-RAY CRYSTALLOGRAPHY

被引:26
作者
STANTON, M [1 ]
PHILLIPS, WC [1 ]
OMARA, D [1 ]
NADAY, I [1 ]
WESTBROOK, E [1 ]
机构
[1] ARGONNE NATL LAB,ARGONNE,IL 60439
关键词
D O I
10.1016/0168-9002(93)90405-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performance of laboratory and synchrotron CCD-based detectors for X-ray crystallography is modeled using expressions which describe both the detector and the experiment. The detectors are constructed from an array of identical modules, each module consisting of a phosphor X-ray-to-light convertor, a fiberoptic taper and a CCD. The performance is characterized by the detective quantum efficiency (DOE) and dynamic range (DR), and by four additional expressions; the detective collective efficiency (DCE), experimental detective quantum efficiency (XDQE), experimental detective collection efficiency (XDCE) and experimental dynamic range (XDR). These additional expressions provide a means for including experimental constraints in the design of the detector. For a crystallography detector, these constraints include the requirements that the detector a) integrate Bragg peaks to maximum precision, and b) efficiently collect data to high resolution (large Bragg angle. Results obtained using these expressions demonstrate the need for a detector with a relatively large area. In order to build a such a detector from a reasonable number of modules using currently available fiberoptic tapers and CCDs, tapers with a demagnification ratio of > 3 : 1 are required. A different conclusion would be arrived at if the DQE alone were considered, demonstrating the importance of this method.
引用
收藏
页码:558 / 567
页数:10
相关论文
共 50 条
[31]   PILATUS: A 2-DIMENSIONAL X-RAY DETECTOR FOR MACROMOLECULAR CRYSTALLOGRAPHY [J].
Eikenberry, E. ;
Broennimann, Ch. ;
Huelsen, G. ;
Toyokawa, H. ;
Horisberger, R. ;
Scmitt, B. ;
Schulze-Briese, C. ;
Tomizaki, T. .
ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 :C236-C236
[32]   Studies of an X-ray imaging detector based on THGEM and CCD camera [J].
Peng, Zhi-Yuan ;
Gu, Yung-Ting ;
Xie, Yu-Guang ;
Yan, Wen-Qi ;
Zhao, Hang ;
Li, Geng-Lan ;
Jiang, Jie-Chen ;
Feng, Huan-Bo ;
Wang, Zhi-Gang ;
Lv, Jun-Guang ;
Hu, Tao ;
Zhou, Li .
RADIATION DETECTION TECHNOLOGY AND METHODS, 2018, 2 (01)
[33]   X-ray polarimetry using the photoeffect in a CCD detector [J].
Buschhorn, G. ;
Kotthaus, R. ;
Kufner, W. ;
Roessl, W. ;
Rzepka, M. ;
Schmidt, K.H. ;
Genz, H. ;
Graef, H.-D. ;
Hoffmann-Stascheck, P. ;
Nething, U. ;
Richter, A. ;
Dix, W.-R. ;
Illing, G. ;
Lohmann, M. ;
Pflueger, J. .
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A346 (03) :578-588
[34]   Scanning CCD Detector for X-ray Powder Diffraction [J].
Madden, T. ;
Baldwin, J. ;
Von Dreele, R. ;
Suchomel, M. ;
Toby, B. H. .
17TH PAN-AMERICAN SYNCHROTRON RADIATION INSTRUMENTATION CONFERENCE SRI2013, 2014, 493
[35]   X-RAY POLARIMETRY USING THE PHOTOEFFECT IN A CCD DETECTOR [J].
BUSCHHORN, G ;
KOTTHAUS, R ;
KUFNER, W ;
ROSSL, W ;
RZEPKA, M ;
SCHMIDT, KH ;
GENZ, H ;
GRAF, HD ;
HOFFMANNSTASCHECK, P ;
NETHING, U ;
RICHTER, A ;
DIX, WR ;
ILLING, G ;
LOHMANN, M ;
PFLUGER, J ;
REIME, B ;
SCHILDWACHTER, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (03) :578-588
[36]   Developments in CCD-based beta/X-ray imaging [J].
Wells, K ;
Kokkinou, E ;
Petrou, M ;
Ranicar, A ;
Spinks, T ;
Ott, RJ .
PENETRATING RADIATION SYSTEMS AND APPLICATIONS III, 2001, 4508 :99-110
[37]   Spatial resolution of a hard x-ray CCD detector [J].
Seely, John F. ;
Pereira, Nino R. ;
Weber, Bruce V. ;
Schumer, Joseph W. ;
Apruzese, John P. ;
Hudson, Lawrence T. ;
Szabo, Csilla I. ;
Boyer, Craig N. ;
Skirlo, Scott .
APPLIED OPTICS, 2010, 49 (23) :4372-4378
[38]   Evaluation of a YAG:Ce scintillation crystal based CCD X-ray imaging detector with the Medipix2 detector [J].
Tous, J. ;
Blazek, J. ;
Zemlicka, J. ;
Jakubek, J. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[39]   DEVELOPMENT OF A MULTIWIRE PROPORTIONAL CHAMBER AS AN AREA SENSITIVE DETECTOR FOR X-RAY PROTEIN CRYSTALLOGRAPHY [J].
BADE, D ;
PARAK, F ;
MOSSBAUER, RL ;
HOPPE, W ;
LEVAI, N ;
CHARPAK, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01) :193-196
[40]   Design of X-ray energy detector [J].
Zeng, Fan ;
Zhu, Zhiyuan .
ENERGY REPORTS, 2022, 8 :456-460