AREA DETECTOR DESIGN .2. APPLICATION TO A MODULAR CCD-BASED DETECTOR FOR X-RAY CRYSTALLOGRAPHY

被引:26
作者
STANTON, M [1 ]
PHILLIPS, WC [1 ]
OMARA, D [1 ]
NADAY, I [1 ]
WESTBROOK, E [1 ]
机构
[1] ARGONNE NATL LAB,ARGONNE,IL 60439
关键词
D O I
10.1016/0168-9002(93)90405-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performance of laboratory and synchrotron CCD-based detectors for X-ray crystallography is modeled using expressions which describe both the detector and the experiment. The detectors are constructed from an array of identical modules, each module consisting of a phosphor X-ray-to-light convertor, a fiberoptic taper and a CCD. The performance is characterized by the detective quantum efficiency (DOE) and dynamic range (DR), and by four additional expressions; the detective collective efficiency (DCE), experimental detective quantum efficiency (XDQE), experimental detective collection efficiency (XDCE) and experimental dynamic range (XDR). These additional expressions provide a means for including experimental constraints in the design of the detector. For a crystallography detector, these constraints include the requirements that the detector a) integrate Bragg peaks to maximum precision, and b) efficiently collect data to high resolution (large Bragg angle. Results obtained using these expressions demonstrate the need for a detector with a relatively large area. In order to build a such a detector from a reasonable number of modules using currently available fiberoptic tapers and CCDs, tapers with a demagnification ratio of > 3 : 1 are required. A different conclusion would be arrived at if the DQE alone were considered, demonstrating the importance of this method.
引用
收藏
页码:558 / 567
页数:10
相关论文
共 50 条
[21]   SPHERICAL DRIFT CHAMBER AREA DETECTOR FOR X-RAY CRYSTALLOGRAPHY [J].
BOLON, C ;
DEUTSCH, M ;
LANZA, R ;
QUIGLEY, G ;
RICH, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) :146-149
[22]   X-ray pixel detector for crystallography [J].
Delpierre, P ;
Berar, JF ;
Blanquart, L ;
Caillot, B ;
Clemens, JC ;
Mouget, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :987-991
[23]   DETECTOR SYSTEM FOR X-RAY CRYSTALLOGRAPHY [J].
LI, YU ;
PHILLIPS, WC ;
STANTON, M ;
KALATA, K .
FASEB JOURNAL, 1992, 6 (01) :A447-A447
[24]   Large area direct X-ray conversion detector for protein crystallography [J].
Sultana, Afrin ;
Karim, K. S. ;
Rowlands, J. A. .
2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, :947-950
[25]   A large area CCD X-ray detector for exotic atom spectroscopy [J].
Nelms, N ;
Anagnostopoulos, DF ;
Ayranov, O ;
Borchert, G ;
Egger, JP ;
Gotta, D ;
Hennebach, M ;
Indelicato, P ;
Leoni, B ;
Liu, YW ;
Manil, B ;
Simons, LM ;
Wells, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3) :419-431
[26]   Radionuclide Imaging with a CCD-Based, High-Resolution X-Ray Detector in Single Photon Counting Mode [J].
Panse, A. ;
Jain, A. ;
Wang, W. ;
Yao, R. ;
Bednarek, D. ;
Rudin, S. .
MEDICAL PHYSICS, 2010, 37 (06)
[27]   Application of a CCD-based X-ray diffractometer to polymer fibre diffraction [J].
Hanna, S ;
Baker, AME ;
Windle, AH .
POLYMER, 1998, 39 (12) :2409-2414
[28]   Application of a CCD-based X-ray diffractometer to polymer fibre diffraction [J].
Univ Cambridge, Pembroke St, Cambridge CB2 3QZ, United Kingdom .
Polymer, 12 (2409-2914)
[29]   A 3 x 6 arrayed CCD X-ray detector for continuous rotation method in macromolecular crystallography [J].
Ito, Kazuki ;
Gaponov, Yurii ;
Sakabe, Noriyoshi ;
Amemiya, Yoshiyuki .
JOURNAL OF SYNCHROTRON RADIATION, 2007, 14 :144-150
[30]   POSITION SENSITIVE PROPORTIONAL DETECTOR FOR X-RAY CRYSTALLOGRAPHY [J].
GABRIEL, A ;
DUPONT, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (11) :1600-&