Cerebrospinal Fluid Glucose Measurement at Point-of-Care

被引:0
|
作者
Thomas, Steven
Halstead, Anne Catherine [1 ,2 ,3 ]
Douglas, M. Joanne
Villar, Giselle
Saran, Simrat
Kozak, Elvira
机构
[1] Childrens & Womens Hlth Ctr British Columbia, Dept Pathol, 4480 Oak St, Vancouver, BC V6H 3V4, Canada
[2] Univ British Columbia, Dept Pathol, Vancouver, BC, Canada
[3] Univ British Columbia, Lab Med, Vancouver, BC, Canada
来源
POINT OF CARE | 2012年 / 11卷 / 02期
关键词
cerebrospinal fluid; glucose; point-of-care; spinal anesthesia; failed epidural anesthesia;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The ability to confirm that the fluid obtained during attempted spinal anesthesia after failed epidural anesthesia is cerebrospinal fluid (CSF) would be useful to the obstetric anesthesiologist. This study was designed to determine whether 3 point-of-care glucose devices (Precision Xtra [Abbott Point of Care], StatStrip Glucose Monitor [Nova Biomedical], and ACCU-CHEK Inform II [Roche Diagnostics]) would reliably measure glucose in CSF during routine spinal anesthesia for cesarean section. A sample of CSF was removed after dural puncture, and glucose was tested using all 3 devices at point-of-care. Results were compared with laboratory CSF glucose measurement (Vitros instruments [Ortho Clinical Diagnostics]). Ease of use of the 3 glucose monitors in the operating room setting and the relationship between blood and CSF glucose levels were also examined. Thirty women were studied. With one exception, blood glucose levels were normal. The StatStrip Glucose Monitor and the ACCU-CHEK Inform II gave similar results of CSF glucose as a percentage of blood glucose in most samples. There was no correlation between the length of fast and CSF glucose results. Both the StatStrip Glucose Monitor and the ACCU-CHEK Inform II showed good agreement with laboratory CSF glucose. There was a significant positive bias with the Precision Xtra device. This study confirmed that some point-of-care devices can measure CSF glucose level reliably in the operating room setting. Further studies are needed to see if this will prove useful during attempted spinal anesthesia after failed epidural anesthesia.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 50 条
  • [31] Agreement between point-of-care glucometry, blood gas and laboratory-based measurement of glucose in an equine neonatal intensive care unit
    Russell, C.
    Palmer, J. E.
    Boston, R. C.
    Wilkins, P. A.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2007, 17 (03) : 236 - 242
  • [32] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Walther, Louise Houlberg
    Zegers, Floor
    Nybo, Mads
    Mogensen, Christian Backer
    Christensen, Erika Frischknecht
    Lassen, Annmarie Touborg
    Mikkelsen, Soren
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1679 - 1687
  • [33] A Point-of-Care Measurement of NT-proBNP for Heart Failure Patients
    Navarro, Cesar
    Fishlock, Sam Jeffery
    Steele, David N.
    Puttaswamy, Srinivasu Valagerahally
    Lubarsky, Gennady
    Raj, Shasidran
    Mclaughlin, James
    IEEE ACCESS, 2020, 8 : 138973 - 138983
  • [34] Direct hemoglobin measurement on a centrifugal microfluidic platform for point-of-care diagnostics
    Steigert, J.
    Grumann, M.
    Dube, M.
    Streule, W.
    Riegger, L.
    Brenner, T.
    Koltay, P.
    Mittmann, K.
    Zengerle, R.
    Ducree, J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 130 (SPEC. ISS.) : 228 - 233
  • [35] The Usefulness and Limitations of Point-of-care Cardiac Troponin Measurement in the Emergency Department
    Suzuki, Kenichiro
    Komukai, Kimiaki
    Nakata, Kotaro
    Kang, Ryeonshi
    Oi, Yuhei
    Muto, Eri
    Kashiwagi, Yusuke
    Tominaga, Mitsutoshi
    Miyanaga, Satoru
    Ishikawa, Tetsuya
    Okuno, Kenji
    Uzura, Masahiko
    Yoshimura, Michihiro
    INTERNAL MEDICINE, 2018, 57 (12) : 1673 - 1680
  • [36] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Louise Houlberg Walther
    Floor Zegers
    Mads Nybo
    Christian Backer Mogensen
    Erika Frischknecht Christensen
    Annmarie Touborg Lassen
    Søren Mikkelsen
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1679 - 1687
  • [37] Blood glucose is correlated with cerebrospinal fluid neurotransmitter metabolites
    Umhau, JC
    Petrulis, SG
    Diaz, R
    Rawlings, R
    George, DT
    NEUROENDOCRINOLOGY, 2003, 78 (06) : 339 - 343
  • [38] Point-of-care testing on admission to the intensive care unit: lactate and glucose independently predict mortality
    Martin, Jan
    Blobner, Manfred
    Busch, Raymonde
    Moser, Norman
    Kochs, Eberhard
    Luppa, Peter B.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (02) : 405 - 412
  • [39] What's New in Point-of-Care Testing?
    Foran-Melanson, Stacy E.
    POINT OF CARE, 2008, 7 (03): : 83 - 85
  • [40] Accuracy and validation of a point-of-care blood glucose monitoring system for use in horses
    Velineni, Sridhar
    Schiltz, Paul
    Chang, Ko-Hsin
    Peng, Yi-Ming
    Cowles, Bobby
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11