Cerebrospinal Fluid Glucose Measurement at Point-of-Care

被引:0
|
作者
Thomas, Steven
Halstead, Anne Catherine [1 ,2 ,3 ]
Douglas, M. Joanne
Villar, Giselle
Saran, Simrat
Kozak, Elvira
机构
[1] Childrens & Womens Hlth Ctr British Columbia, Dept Pathol, 4480 Oak St, Vancouver, BC V6H 3V4, Canada
[2] Univ British Columbia, Dept Pathol, Vancouver, BC, Canada
[3] Univ British Columbia, Lab Med, Vancouver, BC, Canada
来源
POINT OF CARE | 2012年 / 11卷 / 02期
关键词
cerebrospinal fluid; glucose; point-of-care; spinal anesthesia; failed epidural anesthesia;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The ability to confirm that the fluid obtained during attempted spinal anesthesia after failed epidural anesthesia is cerebrospinal fluid (CSF) would be useful to the obstetric anesthesiologist. This study was designed to determine whether 3 point-of-care glucose devices (Precision Xtra [Abbott Point of Care], StatStrip Glucose Monitor [Nova Biomedical], and ACCU-CHEK Inform II [Roche Diagnostics]) would reliably measure glucose in CSF during routine spinal anesthesia for cesarean section. A sample of CSF was removed after dural puncture, and glucose was tested using all 3 devices at point-of-care. Results were compared with laboratory CSF glucose measurement (Vitros instruments [Ortho Clinical Diagnostics]). Ease of use of the 3 glucose monitors in the operating room setting and the relationship between blood and CSF glucose levels were also examined. Thirty women were studied. With one exception, blood glucose levels were normal. The StatStrip Glucose Monitor and the ACCU-CHEK Inform II gave similar results of CSF glucose as a percentage of blood glucose in most samples. There was no correlation between the length of fast and CSF glucose results. Both the StatStrip Glucose Monitor and the ACCU-CHEK Inform II showed good agreement with laboratory CSF glucose. There was a significant positive bias with the Precision Xtra device. This study confirmed that some point-of-care devices can measure CSF glucose level reliably in the operating room setting. Further studies are needed to see if this will prove useful during attempted spinal anesthesia after failed epidural anesthesia.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 50 条
  • [21] Evaluation of point-of-care capillary and venous blood glucose concentrations in hospitalized neonatal foals
    Moreira, Ana Sofia Dias
    Weng, Hsin-Yi
    Hostnik, Laura D.
    Beasley, Erin M.
    Peek, Simon F.
    Munsterman, Amelia S.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2024, 34 (06) : 570 - 578
  • [22] Point-of-Care Capillary Compared to Venous Bilirubin Measurement in Neonates
    Rallis, Dimitrios
    Baltogianni, Maria
    Maragoudaki, Elena
    Tseklazi, Paschalina
    Kapetaniou, Konstantina
    Giapros, Vasileios
    INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2024,
  • [23] Clinical impact of point-of-care vs laboratory measurement of anticoagulation
    Sunderji, R
    Gin, K
    Shalansky, K
    Carter, C
    Chambers, K
    Davies, C
    Schwartz, L
    Fung, A
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 123 (02) : 184 - 188
  • [24] Cerebrospinal fluid glucose is not altered in patients with dementia
    Jensen, Camilla Steen
    Gleerup, Helena Sophia
    Musaeus, Christian Sandoe
    Hasselbalch, Steen Gregers
    Hogh, Peter
    Waldemar, Gunhild
    Simonsen, Anja Hviid
    CLINICAL BIOCHEMISTRY, 2023, 112 : 1 - 5
  • [25] Assessment of Point-of-Care Measurement of Urinary Creatinine and Electrolytes in the Intensive Care Unit
    Calzavacca, Paolo
    Tee, Augustine
    Licari, Elisa
    Bellomo, Rinaldo
    RENAL FAILURE, 2010, 32 (01) : 27 - 31
  • [26] The application of personal glucose meters as universal point-of-care diagnostic tools
    Lisi, Fabio
    Peterson, Joshua R.
    Gooding, J. Justin
    BIOSENSORS & BIOELECTRONICS, 2020, 148 (148):
  • [27] Point-of-care testing for measuring haemolymph glucose in invertebrates is not a valid method
    Principe, Silas C.
    Augusto, Alessandra
    Costa, Tania M.
    CONSERVATION PHYSIOLOGY, 2019, 7
  • [28] Predictors of Time-to-Repeat Point-of-Care Glucose Following Hypoglycemic Events in Hospitalized Patients
    Abusamaan, Mohammed S.
    Klonoff, David C.
    Mathioudakis, Nestoras
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (03): : 526 - 534
  • [29] Clinical Reliability of Point-of-Care Glucose Testing in Critically Ill Patients
    Pilackas, Kylie
    El-Oshar, Seraj
    Carter, Chris
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (01): : 65 - 69
  • [30] Point-of-care testing
    Anderson D.A.
    Crowe S.M.
    Garcia M.
    Current HIV/AIDS Reports, 2011, 8 (1) : 31 - 37