Long-term Results After Transcatheter Aortic Valve Implantation: What do we Know Today?

被引:12
作者
Elhmidi, Y. [1 ]
Bleiziffer, S. [1 ]
Piazza, N. [1 ]
Voss, B. [1 ]
Krane, M. [1 ]
Deutsch, M-A. [1 ]
Lange, R. [1 ]
机构
[1] German Heart Ctr Munich, Dept Cardiovasc Surg, Lazarettestr 36, Munich, Germany
关键词
Aortic valve; TAVI; paravalvular leakage; aortic stenosis; SAVR;
D O I
10.2174/1573403X09666131202124227
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation (TAVI) is evolving rapidly as a therapeutic option in patients deemed to be at high risk for surgical aortic valve replacement. Early outcome and survival of controlled feasibility trials and single-center experience with TAVI have been previously reported. Valve performance and hemodynamics seem to improve significantly after TAVI. Long-term outcome up to 3 years have been demonstrated in recent studies. Admittedly, the results are encouraging with a survival rate at 2 and 3 years ranging from 62 to 74% and from 56 to 61% respectively. The improvement in hemodynamical and clinical status sustained beyond the 3 years follows up. However, paravalvular leakage after TAVI remains an important issue in this rapidely evolving field.
引用
收藏
页码:295 / 298
页数:4
相关论文
共 33 条
[1]   Beyond the short-term: Clinical outcome and valve performance 2 years after transcatheter aortic valve implantation in 227 patients [J].
Bleiziffer, Sabine ;
Mazzitelli, Domenico ;
Opitz, Anke ;
Hettich, Ina ;
Ruge, Hendrik ;
Piazza, Nicolo ;
Lange, Ruediger .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (02) :310-317
[2]   Valve Implantation on the Beating Heart Catheter-Assisted Surgery for Aortic Stenosis [J].
Bleiziffer, Sabine ;
Ruge, Hendrik ;
Mazzitelli, Domenico ;
Schreiber, Christian ;
Hutter, Andrea ;
Krane, Markus ;
Bauernschmitt, Robert ;
Lange, Ruediger .
DEUTSCHES ARZTEBLATT INTERNATIONAL, 2009, 106 (14) :235-241
[3]   2-Year Follow-Up of Patients Undergoing Transcatheter Aortic Valve Implantation Using a Self-Expanding Valve Prosthesis [J].
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Schuler, Gerhard ;
Bonan, Raoul ;
Kovac, Jan ;
Serruys, Patrick W. ;
Labinaz, Marino ;
den Heijer, Peter ;
Mullen, Michael ;
Tymchak, Wayne ;
Windecker, Stephan ;
Mueller, Ralf ;
Grube, Eberhard .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (16) :1650-1657
[4]   Impact of left ventricular systolic function on clinical and echocardiographic outcomes following transcatheter aortic valve implantation for severe aortic stenosis [J].
Ewe, See Hooi ;
Marsan, Nina Ajmone ;
Pepi, Mauro ;
Delgado, Victoria ;
Tamborini, Gloria ;
Muratori, Manuela ;
Ng, Arnold C. T. ;
van der Kley, Frank ;
de Weger, Arend ;
Schalij, Martin J. ;
Fusari, Melissa ;
Biglioli, Paolo ;
Bax, Jeroen J. .
AMERICAN HEART JOURNAL, 2010, 160 (06) :1113-1120
[5]   Clinical outcome of transcatheter aortic valve implantation in patients with low-flow, low gradient aortic stenosis [J].
Gotzmann, Michael ;
Lindstaedt, Michael ;
Bojara, Waldemar ;
Ewers, Aydan ;
Muegge, Andreas .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (05) :693-701
[6]   Hemodynamic results and changes in myocardial function after transcatheter aortic valve implantation [J].
Gotzmann, Michael ;
Lindstaedt, Michael ;
Bojara, Waldemar ;
Muegge, Andreas ;
Germing, Alfried .
AMERICAN HEART JOURNAL, 2010, 159 (05) :926-932
[7]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76
[8]   Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease - The Siegburg First-in-Man Study [J].
Grube, Eberhard ;
Laborde, Jean C. ;
Gerckens, Ulrich ;
Felderhoff, Thomas ;
Sauren, Barthel ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
Menichelli, Maurizio ;
Schmidt, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Stone, Gregg W. .
CIRCULATION, 2006, 114 (15) :1616-1624
[9]   Transcatheter Aortic Valve Implantation Durability of Clinical and Hemodynamic Outcomes Beyond 3 Years in a Large Patient Cohort [J].
Gurvitch, R. ;
Wood, D. A. ;
Tay, E. L. ;
Leipsic, J. ;
Ye, J. ;
Lichtenstein, S. V. ;
Thompson, C. R. ;
Carere, R. G. ;
Wijesinghe, N. ;
Nietlispach, F. ;
Boone, R. H. ;
Lauck, S. ;
Cheung, A. ;
Webb, J. G. .
CIRCULATION, 2010, 122 (13) :1319-1327
[10]   Aortic Annulus Diameter Determination by Multidetector Computed Tomography Reproducibility, Applicability, and Implications for Transcatheter Aortic Valve Implantation [J].
Gurvitch, Ronen ;
Webb, John G. ;
Yuan, Ren ;
Johnson, Mark ;
Hague, Cameron ;
Willson, Alexander B. ;
Toggweiler, Stefan ;
Wood, David A. ;
Ye, Jian ;
Moss, Robert ;
Thompson, Christopher R. ;
Achenbach, Stephan ;
Min, James K. ;
LaBounty, Troy M. ;
Cury, Ricardo ;
Leipsic, Jonathon .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) :1235-1245