QUANTITATIVE IMAGING OF HO-166 WITH AN ANGER CAMERA

被引:12
|
作者
BAYOUTH, JE
MACEY, DJ
机构
[1] Dept. of Radiat. Phys., Texas Univ., M.D. Anderson Cancer Center, Houston, TX
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1994年 / 39卷 / 02期
关键词
D O I
10.1088/0031-9155/39/2/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to develop a quantitative Anger camels imaging approach for Ho-166 in the skeletal system of patients. A dual energy window method was designed to subtract the interference from septal penetration and bremsstrahlung events in Anger camera images acquired with the 80 keV x-rays emitted by Ho-166. The validity of this scatter subtraction method for Ho-166 images was demonstrated as improvements of the line spread function and modulation transfer function. Camera sensitivity was found to be nearly independent of source-to-collimator distance only for images acquired with a high-energy collimator. Studies in an Alderson abdominal water phantom demonstrated scatter subtraction can provide quantitative Anger camera images of Ho-166 with a scatter multiplier of k=1.0 and a correction for attenuation. Attenuation correction factors derived from a transmission image were measured for the phantom and verified with water-equivalent blocks of known thickness. Whole-body scan images of Ho-166 localized in the skeletal system of patients were significantly improved with this simple scatter subtraction method, and when used to estimate the activity distribution within separate bone regions of the skeleton.
引用
收藏
页码:265 / 279
页数:15
相关论文
共 50 条
  • [1] PLANAR GAMMA-CAMERA IMAGING OF HO-166
    BAYOUTH, JE
    MACEY, DJ
    DESAI, FR
    KASI, LP
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P180 - P180
  • [2] Quantitative imaging of holmium-166 with an anger camera
    1600, Publ by Institute of Physics Publishing Ltd, Bristol, Engl (39):
  • [3] ON THE HO-166 DISINTEGRATION
    SIEGBAHN, K
    SLATIS, H
    ARKIV FOR FYSIK, 1950, 1 (06): : 559 - 562
  • [4] Correction of scatter from septal penetration and tissue for quantitative imaging of Ho-166
    Shen, S
    Breitz, H
    Stabin, M
    Duan, J
    Wendt, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1374 - 1374
  • [5] THE DECAY OF HO-166
    SUNYAR, AW
    PHYSICAL REVIEW, 1954, 93 (06): : 1345 - 1347
  • [6] A RADIOACTIVE ISOMER OF HO-166
    BUTEMENT, FDS
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1952, 65 (388): : 311 - 311
  • [7] A RADIOACTIVE ISOMER OF HO-166
    BUTEMENT, FDS
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION A, 1952, 65 (388): : 254 - 258
  • [8] ROTATIONAL BANDS OF HO-166
    BOLLINGER, LM
    THOMAS, GE
    PHYSICS LETTERS B, 1970, B 32 (06) : 457 - +
  • [9] Neutron resonances in Ho-166
    Huffman, PR
    Frankle, CM
    Gould, CR
    Haase, DG
    Harvey, JA
    Roberson, NR
    Weston, LW
    PHYSICAL REVIEW C, 1996, 54 (04): : 2051 - 2054
  • [10] BETA-SPEKTR HO-166
    ANTONEVA, NM
    BASHILOV, AA
    DZHELEPOV, BS
    ZOLOTAVIN, AV
    DOKLADY AKADEMII NAUK SSSR, 1950, 70 (03): : 397 - 400