IMPROVED CALIBRATION OF A LARGE OPEN-ENDED COAXIAL PROBE FOR DIELECTRIC MEASUREMENTS

被引:30
|
作者
OTTO, GP
CHEW, WC
机构
关键词
D O I
10.1109/19.85345
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The accurate calibration of open-ended coaxial waveguides can be difficult because standard matched loads over a broad frequency range cannot be easily attached without connectors that will affect the measurements. An alternative termination is the open-ended probe immersed in a material with known permittivity. But this termination is often inaccurate due to the multiple sources of uncertainty in the reference permittivity. An improved calibration is obtained by measuring an open, a short, and a short-cavity. This calibration is more accurate than measurements of reference permittivities because it depends only upon the geometry of the probe. The calibration was tested by comparing theoretical and experimental values of the complex permittivity for common liquids, and the discrepancy was seen to be small.
引用
收藏
页码:742 / 746
页数:5
相关论文
共 50 条
  • [1] DIELECTRIC MEASUREMENTS WITH AN OPEN-ENDED COAXIAL PROBE
    MARSLAND, TP
    EVANS, S
    IEE PROCEEDINGS-H MICROWAVES ANTENNAS AND PROPAGATION, 1987, 134 (04) : 341 - 349
  • [2] Open-Ended Coaxial Probe for Dielectric Thickness Measurements
    Bassey, Christopher E.
    BIOPHYSICAL JOURNAL, 2021, 120 (03) : 365A - 365A
  • [3] Design and Calibration of a Large Open-Ended Coaxial Probe for the Measurement of the Dielectric Properties of Concrete
    Filali, Bilal
    Boone, Francois
    Rhazi, Jamal
    Ballivy, Gerard
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (10) : 2322 - 2328
  • [4] Open-Ended Coaxial Probe for Dielectric Property Measurements in Sugar Mills
    Thomason, Scott
    Bialkowski, Konstanty
    PROCEEDINGS OF THE 2019 IEEE ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), 2019, : 1209 - 1211
  • [5] Time Domain Calibration Method of Open-Ended Coaxial Probe in Dielectric Measurement
    Shao, Mingye
    Li, Xiaobin
    Liu, Zhengguang
    Liang, Xingyu
    Lin, Lei
    Fan, Hao
    Xu, Jinghui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [6] Analysis of Calibration Procedure for Open-Ended Coaxial Probe
    Joof, Sulayman
    Aydinalp, Cemanur
    Dilman, Ismail
    Akinci, Mehmet Nuri
    Yilmaz, Tuba
    2022 IEEE USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM), 2022, : 34 - 35
  • [7] BILAYERED DIELECTRIC MEASUREMENT WITH AN OPEN-ENDED COAXIAL PROBE
    CHEN, GW
    LI, K
    JI, Z
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1994, 42 (06) : 966 - 971
  • [8] Effects of Calibration Process on Complex Dielectric Permittivity Measurements with Open-Ended Coaxial Probes
    Dilman, Ismail
    Joof, Sulayman
    Aydnalp, Cemanur
    Akinci, Mehmet Nuri
    Cayoren, Mehmet
    PROCEEDINGS OF THE 2022 21ST MEDITERRANEAN MICROWAVE SYMPOSIUM (MMS 2022), 2022, : 188 - 191
  • [9] Dielectric spectroscopy of breast tissue - Improved model of the precision open-ended coaxial probe
    Popovic, D
    Okoniewski, M
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3791 - 3793
  • [10] Effect of Open-Ended Coaxial Probe-to-Tissue Contact Pressure on Dielectric Measurements
    Maenhout, Gertjan
    Markovic, Tomislav
    Ocket, Ilja
    Nauwelaers, Bart
    SENSORS, 2020, 20 (07)