DIELECTRIC MEASUREMENTS USING A RATIONAL-FUNCTION MODEL

被引:74
作者
ANDERSON, JM [1 ]
SIBBALD, CL [1 ]
STUCHLY, SS [1 ]
机构
[1] CAN ADIAN SPACE AGCY,RADARSAT PROGRAM OFF,OTTAWA,ON,CANADA
关键词
D O I
10.1109/22.275247
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A recently proposed rational function model for the aperture admittance of 50 ohm teflon filled coaxial lines in contact with a homogeneous dielectric is experimentally validated. A calibration technique of the automatic network analyzer utilizing standard terminations and time domain gating is used. Uncertainties in the dielectric properties of reference liquids do not enter the calibration procedure. Experimental results for water and methanol are compared with estimated values. A model expression for the sensitivity of the probe is validated. The sensitivities of two coaxial line probes for the measurements made are determined. Results obtained using the new model are compared with those of other workers.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 17 条
[1]  
Altschuler H. M., 1963, HDB MICROWAVE MEASUR, V2, P495
[2]  
ATHEY TW, 1982, IEEE T MICROWAVE THE, V30
[3]  
BRADY MM, 1981, IEEE T BIO-MED ENG, V28, P305, DOI 10.1109/TBME.1981.324707
[4]   INVIVO PROBE MEASUREMENT TECHNIQUE FOR DETERMINING DIELECTRIC-PROPERTIES AT VHF THROUGH MICROWAVE-FREQUENCIES [J].
BURDETTE, EC ;
CAIN, FL ;
SEALS, J .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1980, 28 (04) :414-427
[5]  
BUSEY HE, 1967, P IEEE, V55, P1046
[6]   AN EQUIVALENT-CIRCUIT OF AN OPEN-ENDED CO-AXIAL LINE [J].
GAJDA, G ;
STUCHLY, SS .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (04) :506-508
[7]  
GRANT JP, 1986, MAY IEE C IND MED AP
[8]   NONINVASIVE ELECTRICAL CHARACTERIZATION OF MATERIALS AT MICROWAVE-FREQUENCIES USING AN OPEN-ENDED COAXIAL LINE - TEST OF AN IMPROVED CALIBRATION TECHNIQUE [J].
MISRA, D ;
CHABBRA, M ;
EPSTEIN, BR ;
MIROTZNIK, M ;
FOSTER, KR .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1990, 38 (01) :8-14
[10]   PERMITTIVITY MEASUREMENTS USING OPEN-ENDED SENSORS AND REFERENCE LIQUID CALIBRATION - AN UNCERTAINTY ANALYSIS [J].
NYSHADHAM, A ;
SIBBALD, CL ;
STUCHLY, SS .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1992, 40 (02) :305-314