REGISTRATION OF 3-DIMENSIONAL COMPOUND ULTRASOUND SCANS OF THE BREAST FOR REFRACTION AND MOTION CORRECTION

被引:55
作者
MOSKALIK, A
CARSON, PL
MEYER, CR
FOWLKES, JB
RUBIN, JM
ROUBIDOUX, MA
机构
[1] Department of Radiology, University of Michigan Medical Center, Ann Arbor, MI
关键词
B-MODE IMAGING; BLOOD FLOW; COLOR FLOW DOPPLER; DOPPLER; IMAGE PROCESSING; IMAGING; SPECKLE; 3-DIMENSIONAL IMAGING;
D O I
10.1016/0301-5629(95)00018-M
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Use of multiple look directions, that is, compound imaging, has been shown previously to increase detection of specular reflectors and averaging of speckle noise in gray-scale images, often at the expense of spatial resolution and other misregistration errors. In color flow imaging, additional view angles can fill in vessels missed due to Doppler angle dropout and increase quantitative and visual Doppler accuracy by triangulation or a simple peak-frequency-shift combination algorithm. Image registration and unwarping throughout multiple three-dimensional (3D) volume sets should correct for many refraction artifacts, motion between and during compounded image sets and even, possibly, positioning errors between image sets, acquired months apart, to display growth of abnormalities. The registration described here does not provide sufficient accuracy for formation of enhanced coherent apertures, but shows promise in some cases to provide superior compound images and possibly comparisons of current and prior studies, In this study, the breast is stabilized by mild compression between a flat plate and a scanning membrane. Registration and unwarping is performed retrospectively on two separate volumetric data sets by defining pairs of corresponding points and, in some cases, Line and plane segments. Three-dimensional linear affine transforms are performed using identified points, lines and planes. 3D nonlinear warped transforms are also possible given adequate numbers of identifiable points. More than two data sets are registered by selecting one as the standard, and registering the remainder to match. The most appropriate algorithm, such as averaging or maximum amplitude, may be used to combine the data sets for display. Significant success has been achieved in compound display of a test object and of the breast in vivo, even when there was relative motion or warping between image sets. In pulse-echo imaging, homologous feature registration for compounding appears to have advantages over mechanically registered compounding methods previously employed in the breast and significant increases in lesion and structural conspicuity are noted due to a reduction in speckle noise. The improvements from compounding in 3D, surface-rendered Doppler imaging of vasculature are striking.
引用
收藏
页码:769 / 778
页数:10
相关论文
共 23 条
[1]   DOPPLER ULTRASOUND COLOR FLOW IMAGING IN THE STUDY OF BREAST-CANCER - PRELIMINARY FINDINGS [J].
ADLER, DD ;
CARSON, PL ;
RUBIN, JM ;
QUINNREID, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (06) :553-559
[2]  
ALPERT NM, 1990, J NUCL MED, V31, P1717
[3]   THE SCANNING ACOUSTIC MICROPROBE .1. ANALYSIS AND SYNTHESIS OF A SPHERICALLY SYMMETRICAL POINT SPREAD FUNCTION [J].
BARBER, FE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (01) :1-10
[4]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[6]   ENHANCED COLOR FLOW IMAGING OF BREAST-CANCER VASCULATURE - CONTINUOUS WAVE DOPPLER AND 3-DIMENSIONAL DISPLAY [J].
CARSON, PL ;
ADLER, DD ;
FOWLKES, JB ;
HARNIST, K ;
RUBIN, J .
JOURNAL OF ULTRASOUND IN MEDICINE, 1992, 11 (08) :377-385
[7]   COLOR DOPPLER SIGNALS FROM BREAST-TUMORS - WORK IN PROGRESS [J].
COSGROVE, DO ;
BAMBER, JC ;
DAVEY, JB ;
MCKINNA, JA ;
SINNETT, HD .
RADIOLOGY, 1990, 176 (01) :175-180
[8]   GEOMETRIC FILTER FOR SPECKLE REDUCTION [J].
CRIMMINS, TR .
APPLIED OPTICS, 1985, 24 (10) :1438-1443
[9]   ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY [J].
EVANS, AC ;
BEIL, C ;
MARRETT, S ;
THOMPSON, CJ ;
HAKIM, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) :513-530
[10]   SPECKLE REDUCTION IN PULSE ECHO ULTRASONIC-IMAGING USING A 2-DIMENSIONAL RECEIVING ARRAY [J].
GIESEY, JJ ;
CARSON, PL ;
FITTING, DW ;
MEYER, CR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) :167-173