CONSTRUCTION AND EVALUATION OF TUBULAR POTENTIOMETRIC DETECTORS SENSITIVE TO CHLORIDE, BROMIDE, AND IODIDE AND BASED ON HOMOGENEOUS CRYSTALLINE MEMBRANES

被引:29
作者
FERREIRA, IMPLVO [1 ]
LIMA, JLFC [1 ]
ROCHA, LSM [1 ]
机构
[1] FAC FARM PORTO,DEPT QUIM FIS,RUA ANIBAL CUNHA 164,P-4000 OPORTO,PORTUGAL
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1993年 / 347卷 / 8-9期
关键词
D O I
10.1007/BF00323813
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of tubular potentiometric detectors is described, without an inner reference solution, sensitive to chloride, bromide, and iodide. They are based on homogeneous crystalline membranes obtained by high-pressure pressing of AgX/Ag2S powdered mixtures (X = Cl, Br and 1). The respective operating characteristics are evaluated by comparison with conventionally-shaped electrodes with the same sensor. In general, the detectors showed similar operating characteristics as those of the corresponding conventional electrodes, namely the concentration range, in which they presented a Nernstian response, an excellent reproducibility, and an extremely rapid response rate which in some cases enabled the FIA manifolds to attain sampling rates of 360 samples/h.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 30 条
[1]   FLOW-THROUGH SANDWICH PVC MATRIX MEMBRANE-ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
LIMA, JLFC ;
MACHADO, AASC ;
PAULIS, JM .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (18) :2291-2303
[2]   FLOW-THROUGH TUBULAR IODIDE AND BROMIDE SELECTIVE ELECTRODES BASED ON EPOXY-RESIN HETEROGENEOUS MEMBRANES [J].
ALEGRET, S ;
FLORIDO, A ;
LIMA, JLFC ;
MACHADO, AASC .
TALANTA, 1989, 36 (08) :825-829
[3]   FLOW-THROUGH TUBULAR PVC MATRIX MEMBRANE-ELECTRODE WITHOUT INNER REFERENCE SOLUTION FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
PAULIS, JM ;
LIMA, JLFC ;
MACHADO, AASC .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :147-152
[4]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[5]  
BARROS MAR, 1983, PORTUGALIAE ELECTROC, V1, P277
[6]   FLOW-INJECTION ANALYSIS WITH ELECTROCHEMICAL DETECTION [J].
CAMMANN, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (06) :691-697
[7]   APPLICATION OF FLOW-INJECTION POTENTIOMETRY TO THE DETERMINATION OF CHLORIDE IN VARIOUS MATRICES [J].
FRENZEL, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :931-937
[8]  
FRENZEL W, 1988, FRESEN Z ANAL CHEM, V326, P689
[9]   FLOW INJECTION ANALYSIS OF ENVIRONMENTAL SAMPLES FOR NITRATE USING AN ION-SELECTIVE ELECTRODE [J].
HANSEN, EH ;
GHOSE, AK ;
RUZICKA, J .
ANALYST, 1977, 102 (1219) :705-713
[10]  
LIMA J L F C, 1989, Journal of Food Composition and Analysis, V2, P356, DOI 10.1016/0889-1575(89)90007-0