A SIMPLE ANALYSIS OF 5 THINNER COMPONENTS IN HUMAN-BODY FLUIDS BY HEADSPACE SOLID-PHASE MICROEXTRACTION (SPME)

被引:36
作者
LEE, XP [1 ]
KUMAZAWA, T [1 ]
SATO, K [1 ]
机构
[1] SHOWA UNIV,SCH MED,DEPT LEGAL MED,SHINAGAWA KU,TOKYO 142,JAPAN
关键词
TOLUENE; BENZENE; N-BUTYL ACETATE; N-BUTANOL; N-ISOAMYL ACETATE; SOLID-PHASE MICROEXTRACTION (SPME); HEADSPACE METHOD; CAPILLARY GAS CHROMATOGRAPHY;
D O I
10.1007/BF01246879
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
A simple method for the extraction of 5 thinner components from human whole blood and urine, using the headspace solid-phase microextraction (SPME) method is presented. After heating a vial containing the samples with 5 compounds (toluene, benzene, n-butyl acetate, n-butanol and n-isoamyl acetate) at 80 degrees C, a polydimethylsiloxane-coated SPME fiber was exposed to the headspace of the vial to allow adsorption of the compounds. The fiber needle was then injected into a capillary gas chromatography (GC) port. The headspace SPME-GC gave intense peaks for each compound and a low level of background noise was seen only for whole blood. Recovery rates of the 5 compounds by use of the headspace SPME-GC were 50-70%. Reproducibility for headspace SPME-GC data were excellent for both body fluids. The calibration curves showed linearity in the range 2-100 ng/0.5 ml whole blood or urine. The detection limits of each compound were 1.1-2.4 ng/0.5 ml sample. The present results on the analysis of 5 thinner components by headspace SPME-GC suggest its applicability to a number of other volatile compounds in forensic toxicology.
引用
收藏
页码:310 / 313
页数:4
相关论文
共 14 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   ANALYSIS OF SUBSTITUTED BENZENE COMPOUNDS IN GROUNDWATER USING SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
MOTLAGH, S ;
LIM, M ;
POTTER, DW ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (05) :979-983
[3]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[4]   SAMPLE HANDLING AND STORAGE FOR THE QUANTITATIVE-ANALYSIS OF VOLATILE COMPOUNDS IN BLOOD - THE DETERMINATION OF TOLUENE BY HEADSPACE GAS-CHROMATOGRAPHY [J].
GILL, R ;
HATCHETT, SE ;
OSSELTON, MD ;
WILSON, HK ;
RAMSEY, JD .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (03) :141-146
[5]   SOLVENTLESS DETERMINATION OF CAFFEINE IN BEVERAGES USING SOLID-PHASE MICROEXTRACTION WITH FUSED-SILICA FIBERS [J].
HAWTHORNE, SB ;
MILLER, DJ ;
PAWLISZYN, J ;
ARTHUR, CL .
JOURNAL OF CHROMATOGRAPHY, 1992, 603 (1-2) :185-191
[6]   COMPONENTS OF PAINT THINNER IN BODY-FLUIDS CLEARLY DETECTED USING THE SALTING-OUT TECHNIQUE [J].
KATO, K ;
NAGATA, T ;
KIMURA, K ;
KUDO, K ;
IMAMURA, T ;
NODA, M .
FORENSIC SCIENCE INTERNATIONAL, 1990, 44 (01) :55-60
[7]  
KATO K, 1990, JPN J LEGAL MED, V44, P223
[8]   DYNAMICS OF ORGANIC-COMPOUND EXTRACTION FROM WATER USING LIQUID-COATED FUSED-SILICA FIBERS [J].
LOUCH, D ;
MOTLAGH, S ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1187-1199
[9]   A SIMPLE, RAPID AND SIMULTANEOUS ANALYSIS OF COMPLEX VOLATILE HYDROCARBON MIXTURES IN BLOOD USING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY WITH A WIDE-BORE CAPILLARY COLUMN [J].
MORINAGA, M ;
HARA, K ;
KAGEURA, M ;
HIEDA, Y ;
TAKAMOTO, M ;
KASHIMURA, S .
ZEITSCHRIFT FUR RECHTSMEDIZIN-JOURNAL OF LEGAL MEDICINE, 1990, 103 (08) :567-572
[10]  
PAGE BD, 1992, J CHROMATOGR, V648, P199