THE LUNG DEPOSITION OF SALBUTAMOL, DIRECTLY LABELED WITH TC-99M, DELIVERED BY PRESSURIZED METERED-DOSE AND DRY POWDER INHALERS

被引:43
作者
BIDDISCOMBE, MF
MELCHOR, R
MAK, VHF
MARRIOTT, RJ
TAYLOR, AJ
SHORT, MD
SPIRO, SG
机构
[1] UNIV COLL HOSP LONDON, DEPT MED PHYS, LONDON WC1E 6AU, ENGLAND
[2] GLAXO GRP RES LTD, DIV PHARM, WARE SG12 0DP, ENGLAND
[3] UNIV COLL HOSP LONDON, DEPT THORAC MED, GOWER ST, LONDON WC1E 6AU, ENGLAND
关键词
TC-99M; SALBUTAMOL; LABEL; METERED DOSE INHALER; DRY POWDER INHALER; CASCADE IMPACTOR; DEPOSITION PATTERN;
D O I
10.1016/0378-5173(93)90330-I
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A method is described for the radiolabelling of the beta2-agonist, salbutamol, with the radionuclide Tc-99m. The technique was used to prepare metered-dose inhalers and dry powder inhalers for inhalation by six normal subjects and the deposition of drug within the lungs was measured. In vitro data are presented from studies using an Andersen cascade impactor which show that salbutamol and Tc-99m in the aerosol discharged by the metered dose inhaler, or drawn through the instrument from a dry powder inhaler, have a closely matched particle size distribution. Data from inhalers containing unlabelled salbutamol showed that the addition of the radiolabel had not significantly altered its distribution. Using a dual headed gamma camera (Siemens Rota Camera), we studied six normal volunteers and measured a mean (+/-SD) lung deposition of 11.3 (2.2)% of the dose discharged from a dry powder inhaler and 24.1 (8.5)% from the metered dose inhaler. The deposition values from the metered dose inhaler are considerably greater than those observed using indirect labelling techniques.
引用
收藏
页码:111 / 121
页数:11
相关论文
共 14 条
[1]   DELIVERY OF PROPELLANT SOLUBLE DRUG FROM A METERED DOSE INHALER [J].
ASHWORTH, HL ;
WILSON, CG ;
SIMS, EE ;
WOTTON, PK ;
HARDY, JG .
THORAX, 1991, 46 (04) :245-247
[2]  
HINDS WC, 1982, AEROSOL TECHNOLOGY, pCH5
[3]  
KOHLER D, 1988, RESPIRATION, V53, P65
[4]  
MATTHYS H, 1988, ATEMWEG LUNGENKRANK, V14, P485
[5]  
MORROW PE, 1974, AM REV RESPIR DIS, V110, P88
[6]   DO PARTICLE-SIZE AND AIRWAY-OBSTRUCTION AFFECT THE DEPOSITION OF PRESSURIZED INHALATION AEROSOLS [J].
NEWMAN, SP ;
KILLIP, M ;
PAVIA, D ;
MOREN, F ;
CLARKE, SW .
THORAX, 1983, 38 (03) :233-233
[7]  
NEWMAN SP, 1981, THORAX, V36, P52, DOI 10.1136/thx.36.1.52
[8]   IMPROVEMENT OF DRUG DELIVERY WITH A BREATH ACTUATED PRESSURIZED AEROSOL FOR PATIENTS WITH POOR INHALER TECHNIQUE [J].
NEWMAN, SP ;
WEISZ, AWB ;
TALAEE, N ;
CLARKE, SW .
THORAX, 1991, 46 (10) :712-716
[9]   PRESSURISED AEROSOL DEPOSITION IN THE HUMAN-LUNG WITH AND WITHOUT AN OPEN SPACER DEVICE [J].
NEWMAN, SP ;
CLARK, AR ;
TALAEE, N ;
CLARKE, SW .
THORAX, 1989, 44 (09) :706-710
[10]  
RINDERKNECHT J, 1980, AM REV RESPIR DIS, V121, P105