NEW DEVELOPMENTS IN DOUBLE SIDED SILICON STRIP DETECTORS

被引:10
|
作者
BECKER, H
BOULOS, T
CATTANEO, P
DIETL, H
HAUFF, D
HOLL, P
LANGE, E
LUITZ, G
MOSER, HG
SCHWARZ, AS
SETTLES, R
STRUDER, L
KEMMER, J
PRECHTEL, U
ZIEMANN, T
BUTTLER, W
机构
[1] TECH UNIV MUNICH,FAK PHYS,W-8046 GARCHING,GERMANY
[2] MESSERSCHMITT BOLKOW BLOHM GMBH,W-8000 MUNICH 80,GERMANY
[3] FRAUENHOFER INST MIKROELEKTR SYST,W-4100 DUISBURG,GERMANY
关键词
D O I
10.1109/23.106599
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new type of double sided silicon strip detector has been built and tested using high density VLSI readout electronics connected to both sides. Capacitive coupling of the strips to the readout electronics has been achieved by integrating the capacitors into the detector design, which was made possible by introducing a new detector biasing concept. Schemes to simplify the technology of the fabrication of the detectors will be discussed. The static performance properties of the devices as well as implications of the use of VLSI electronics in their readout will be described. Prototype detectors of the described design equipped with high density readout electronics have been installed in the ALEPH detector at LEP. Test results on the performance will be given. Copyright © 1990 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:101 / 106
页数:6
相关论文
共 50 条
  • [21] Results on double-sided ac-coupled silicon strip detectors
    Batignani, G
    Bosisio, L
    Dellamarina, R
    Elmer, P
    Forti, F
    Giorgi, MA
    Rampino, G
    Rizzo, G
    Tritto, S
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1996, 109 (09): : 1319 - 1332
  • [22] Development of double-sided silicon strip detectors (DSSD) for a Compton telescope
    Takeda, Shin'ichiro
    Watanabe, Shin
    Tanaka, Takaaki
    Nakazawa, Kazuhiro
    Takahashi, Tadayuki
    Fukazawa, Yasushi
    Yasuda, Hajimu
    Tajima, Hiroyasu
    Kuroda, Yoshikatsu
    Onishi, Mitsunobu
    Genba, Kei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 859 - 865
  • [23] Heavy ion radiation damage in double-sided silicon strip detectors
    Livingston, K
    Woods, PJ
    Davinson, T
    Shotter, AC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (2-3): : 445 - 451
  • [24] A high resolution beam telescope built with double sided silicon strip detectors
    Celano, L
    Creanza, D
    dePalma, M
    Maggi, G
    Fiore, L
    Paticchio, V
    Raso, G
    Selvaggi, G
    Silvestris, L
    Tempesta, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 381 (01): : 49 - 56
  • [25] Neutron beam profilometer on the base of double-sided silicon strip detectors
    Zamyatin, N., I
    Bystritsky, V. M.
    Kopach, Y. N.
    Aliyev, F. A.
    Grozdanov, D. N.
    Fedorov, N. A.
    Hramko, C.
    Ruskov, I. N.
    Skoy, V. R.
    Slepnev, V. M.
    Wang, D.
    Zubarev, E., V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 898 : 46 - 52
  • [26] FPGA-based readout for double-sided silicon strip detectors
    Becker, M.
    Brinkmann, K. -T.
    Koop, K.
    Schnell, R.
    Wuerschig, T.
    Zaunick, H. -G.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [27] Effects of the interstrip gap on the efficiency and response of Double Sided Silicon Strip Detectors
    Torresi, D.
    Forneris, J.
    Grassi, L.
    Acosta, L.
    Di Pietro, A.
    Figuera, P.
    Fisichella, M.
    Grilj, V.
    Jakic, M.
    Lattuada, M.
    Mijatovic, T.
    Milin, M.
    Prepolec, L.
    Skukan, N.
    Soic, N.
    Stanko, D.
    Tokic, V.
    Uroic, M.
    Zadro, M.
    12TH INTERNATIONAL CONFERENCE ON NUCLEUS-NUCLEUS COLLISIONS 2015, 2016, 117
  • [28] Laser mapping of the inter-strip response in double sided silicon strip detectors for particle identification
    Castoldi, A.
    Guazzoni, C.
    Parsani, T.
    Riccio, F.
    Zambon, P.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [29] Radiation hardness of the HERA-B double-sided silicon strip detectors
    Bauer, C
    Glebe, T
    Knöpfle, KT
    Pugatch, V
    Schwingenheuer, B
    Abt, I
    Dressel, M
    Masciocchi, S
    Perschke, T
    Schaller, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (1-2): : 116 - 120
  • [30] Efficiency of non-uniformly irradiated double-sided silicon strip detectors
    Dubbs, T
    Kashigin, S
    Kratzer, M
    Kroeger, W
    Pulliam, T
    Sadrozinski, HFW
    Schwab, M
    Spencer, E
    Wichmann, R
    Wilder, M
    Unno, Y
    Ohsugi, T
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 488 - 491