QUANTIFICATION OF THE REDUCTION OF GLARE DISABILITY AFTER STANDARD EXTRACAPSULAR CATARACT-SURGERY

被引:2
作者
CINK, DE
SUTPHIN, JE
机构
关键词
BRIGHTNESS ACUITY TESTER; CATARACT; CATARACT SURGERY; GLARE; TRUE VISION ANALYZER;
D O I
10.1016/S0886-3350(13)80077-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Glare disability is often cited as an indication for cataract extraction, but very little objective data exist showing improvement of glare disability following standard extracapsular cataract extraction with posterior chamber intraocular lens implantation. In a series of 25 patients we determined glare disability by the reduction in visual activity with dim room lighting (baseline) and with full room lights; with the brightness acuity tester (BAT) on low, medium, and high; with the true vision analyzer (TVA) glare light. Glare disability was quantified by the difference between the log VA postoperatively and the log VA preoperatively. Glare disability with BAT medium was no different than that with bright room lights (P > .05). Glare disability with BAT high was greater than that with BAT medium (P < .01) but did not differ from that with TVA (P > .05). Glare disability was significantly reduced (P < .01) six weeks postoperatively as measured by all tests except BAT low. Cataract surgery can be expected to reduce glare disability as measured by these tests.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 15 条
[1]  
Hirsch RP, Nadler MP, Miller D, Glare measurement as a predictor of outdoor vision among cataract patients, Ann Ophthalmol, 16, pp. 965-968, (1984)
[2]  
Neumann AC, McCarty GR, Steedle TO, Et al., The relationship between indoor and outdoor Snellen visual acuity in cataract patients, J Cataract Refract Surg, 14, pp. 35-39, (1988)
[3]  
Hess R, Woo G, Vision through cataracts, Invest Ophthalmol Vis Sci, 17, pp. 428-435, (1978)
[4]  
Masket S, Reversal of glare disability after cataract surgery, J Cataract Refract Surg, 15, pp. 165-168, (1989)
[5]  
Westheimer G, Scaling of visual acuity measurements, Arch Ophthalmol, 97, pp. 327-330, (1979)
[6]  
Koch DD, The role of glare testing in managing the cataract patient, Focal Points, 6, (1988)
[7]  
LeClaire J, Nadler MP, Weiss S, Miller D, A new glare tester for clinical testing
[8]  
results comparing normal subjects and variously corrected aphakic patients, Arch Ophthalmol, 100, pp. 153-158, (1982)
[9]  
Hirsch RP, Nadler MP, Miller D, Clinical performance of a disability glare tester, Arch Ophthalmol, 102, pp. 1633-1636, (1984)
[10]  
Holladay JT, Trujillo J, Prager TC, Ruiz RS, Brightness acuity test and outdoor visual acuity in cataract patients, J Cataract Refract Surg, 13, pp. 67-69, (1987)