Mixed ion-exchanger chemically modified carbon paste ion-selective electrodes for determination of triprolidine hydrochloride

被引:9
|
作者
Issa, Y. M. [1 ]
Abu Attia, F. M. [2 ]
Ismail, N. S. [2 ]
机构
[1] Cairo Univ, Dept Chem, Fac Sci, Giza, Egypt
[2] Natl Org Drug Control & Res, Cairo, Egypt
关键词
Chemically modified carbon paste ion-selective electrode; Triprolidine hydrochloride; Potentiometeric determination; Flow injection analysis; Standard addition method;
D O I
10.1016/j.jare.2010.02.006
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Triprolidine hydrochloride (TpCl) ion-selective carbon paste electrodes were constructed using Tp-TPB/Tp-CoN and Tp-TPB/Tp-PTA as ion-exchangers.The two electrodes revealed Nernstian responses with slopes of 58.4 and 58.1 mV decade -1 at 25 degrees C in the ranges 6 x 10(-6) 1 x 10(-2) and 2 x 10(-5) 1 x 10(-2) M for Tp-TPB/Tp-CoN and Tp-TPB/Tp-PTA, respectively. The potentials of these electrodes were independent of pH in the ranges of 2.5-7.0 and 4.5-7.0, and detection limits were 6 x 10(-6) and 1 x 10(-5) M for Tp-TPB/Tp-CoN and Tp-TPB/Tp-PTA, respectively. The electrodes showed a very good selectivity for TpCl with respect to a large number of inorganic cations and compounds. The standard addition, potentiometric titration methods and FIA were applied to the determination of TpCl in pure solutions and pharmaceutical preparations. The results obtained were in close agreement with those found by the official method. The mean recovery values were 100.91% and 97.92% with low coefficient of variation values of 0.94%, and 0.56% in pure solutions, 99.82% and 98.53% with coefficient of variation values of 2.20%, and 0.73% for Actifed tablet and Actifed syrup, respectively, using the Tp-TPB/Tp-CoN electrode, and 98.85%, and 99.18% with coefficient of variation values of 0.48% and 0.85% for Actifed tablet and Actifed syrup, respectively, using the Tp-TPB/Tp-PTA electrode. (C) 2009 University of Cairo. All rights reserved.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [21] DETERMINATION OF SODIUM WITH ION-SELECTIVE ELECTRODES
    LEVY, GB
    CLINICAL CHEMISTRY, 1981, 27 (08) : 1435 - 1438
  • [22] DETERMINATION OF HALIDES WITH ION-SELECTIVE ELECTRODES
    KATZ, DA
    MUKHERJI, AK
    MICROCHEMICAL JOURNAL, 1968, 13 (04) : 604 - &
  • [23] DETERMINATION OF HALIDES WITH ION-SELECTIVE ELECTRODES
    PUNGOR, E
    FEHER, Z
    LINDNER, E
    NAGY, G
    TOTH, K
    ZEITSCHRIFT FUR CHEMIE, 1979, 19 (10): : 367 - 371
  • [24] CARBON SUBSTRATE ION-SELECTIVE ELECTRODES
    MIDGLEY, D
    MULCAHY, DE
    ION-SELECTIVE ELECTRODE REVIEWS, 1983, 5 (02): : 165 - 242
  • [25] ION-SELECTIVE CARBON-PASTE ELECTRODES FOR HALIDES AND SILVER(I) IONS
    MESARIC, S
    DAHMEN, EAMF
    ANALYTICA CHIMICA ACTA, 1973, 64 (03) : 431 - 438
  • [26] Selectivity of voltammetric determination at an ion-exchanger modified electrode
    Labuda, J
    Bucková, M
    ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (05) : 322 - 324
  • [27] Potentiometric ion-selective electrodes for determination of cyclopentolate hydrochloride and phenylephrine hydrochloride in their challenging ophthalmic formulation
    Rezk, Mamdouh R.
    Fayed, Ahmed S.
    Marzouk, Hoda M.
    Abbas, Samah S.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2018, 22 (11) : 3351 - 3361
  • [28] Potentiometric ion-selective electrodes for determination of cyclopentolate hydrochloride and phenylephrine hydrochloride in their challenging ophthalmic formulation
    Mamdouh R. Rezk
    Ahmed S. Fayed
    Hoda M. Marzouk
    Samah S. Abbas
    Journal of Solid State Electrochemistry, 2018, 22 : 3351 - 3361
  • [29] USE OF ION-SELECTIVE ELECTRODES FOR DETERMINATION OF MIXED STABILITY-CONSTANTS
    HEFTER, G
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1972, 39 (02): : 345 - &
  • [30] Square wave anodic stripping determination of silver using a carbon paste electrode modified with a strong acid ion-exchanger
    Gellon, H
    González, PS
    Fontan, CA
    ANALYTICAL LETTERS, 2003, 36 (13) : 2749 - 2765