REDUCED VARIABILITY OF INTERPRETATION AND IMPROVED IMAGE QUALITY WITH A TC-99M MYOCARDIAL PERFUSION AGENT - COMPARISON OF TL-201 AND TC-99M-LABELED TETROFOSMIN

被引:37
作者
HENDEL, RC
PARKER, MA
WACKERS, FJT
RIGO, P
LAHIRI, A
ZARET, BL
机构
[1] YALE UNIV,SCH MED,DEPT INTERNAL MED,DIV CARDIOVASC MED,NEW HAVEN,CT 06510
[2] STATE UNIV LIEGE,DEPT MED,DIV CARDIOL,B-4000 LIEGE,BELGIUM
[3] NORTHWICK PK HOSP & CLIN RES CTR,DEPT CARDIOL,HARROW HA1 3UJ,MIDDX,ENGLAND
关键词
TETROFOSMIN; THALLIUM; MYOCARDIAL PERFUSION IMAGING; RADIOISOTOPE; CORONARY ARTERY DISEASE;
D O I
10.1007/BF02939973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to determine the relative image quality and interobserver variability among four readers for Tl-201 and 99mTc-labeled tetrofosmin myocardial perfusion images. 99mTc-labeled perfusion agents, with near-optimal physical characteristics for gamma camera imaging, may allow for superior image quality and improved consistency of interpretation. However, most studies to date have demonstrated only similarity in the diagnostic accuracy between technetium agents and thallium. Tetrofosmin is a recently developed 99mTc-labeled agent that has shown promising results in early clinical trials. Methods and Results. A multicenter, open-label trial was performed during which treadmill exercise thallium and tetrofosmin scintigraphy was performed within a 2-week period of each other in 216 subjects. Image quality was evaluated subjectively and scans were interpreted in a blinded, independent fashion by four readers. Perfusion abnormalities were graded as consistent with ischemia, infarction, or mixed and were described both globally and regionally. Interobserver variability was assessed by use of the kappa statistic, and receiver-operator curves were compared for each observer for the diagnostic accuracy of each agent. More tetrofosmin images were of excellent quality than with thallium (52% vs 28%; p < 0.05), and when differences in quality were noted between the agents, tetrofosmin was more often superior (p < 0.0001). The interobserver variability was lower with tetrofosmin scintigraphy because generally higher kappa values were noted, especially in the lateral wall. Higher receiver-operator curve areas indicative of improved diagnostic accuracy were noted among the four readers for tetrofosmin in 80% of vascular territories. Conclusions. 99mTc-labeled tetrofosmin scintigraphy yields images of improved quality compared with thallium, and there is an overall improvement in the consistency of image analysis associated with the use of tetrofosmin.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 50 条
[41]   Assessment of transient left ventricular dilatation on rest and exercise on Tc-99m tetrofosmin myocardial SPECT [J].
Kinoshita, N ;
Sugihara, H ;
Adachi, Y ;
Nakamura, T ;
Azuma, A ;
Kohno, Y ;
Nakagawa, M .
CLINICAL NUCLEAR MEDICINE, 2002, 27 (01) :34-39
[42]   PREDICTING RECOVERY OF SEVERE REGIONAL VENTRICULAR DYSFUNCTION - COMPARISON OF RESTING SCINTIGRAPHY WITH TL-201 AND TC-99M-SESTAMIBI [J].
UDELSON, JE ;
COLEMAN, PS ;
METHERALL, J ;
PANDIAN, NG ;
GOMEZ, AR ;
GRIFFITH, JL ;
SHEA, NL ;
OATES, E ;
KONSTAM, MA .
CIRCULATION, 1994, 89 (06) :2552-2561
[43]   Comparison of exercise, dipyridamole, adenosine, and dobutamine stress with the use of Tc-99m tetrofosmin tomographic imaging [J].
Levine, MG ;
Ahlberg, AW ;
Mann, A ;
White, MP ;
McGill, CC ;
de Leon, CM ;
Piriz, JM ;
Waters, D ;
Heller, GV .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (04) :389-396
[44]   MYOCARDIAL VIABILITY ASSESSMENT WITH TECHNETIUM-99M-TETROFOSMIN AND TL-201 REINJECTION IN CORONARY-ARTERY DISEASE [J].
MATSUNARI, I ;
FUJINO, S ;
TAKI, J ;
SENMA, J ;
AOYAMA, T ;
WAKASUGI, T ;
HIRAI, J ;
SAGA, T ;
ICHIYANAGI, K ;
HISADA, K .
JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (11) :1961-1967
[45]   Comparison of exercise, dipyridamole, adenosine, and dobutamine stress with the use of Tc-99m tetrofosmin tomographic imaging [J].
Michael G. Levine ;
Alan W. Ahlberg ;
April Mann ;
Michael P. White ;
Carol C. McGill ;
Carlos Mendes de Leon ;
Jose M. Piriz ;
David Waters ;
Gary V. Heller .
Journal of Nuclear Cardiology, 1999, 6 :389-396
[46]   Abnormal intense skeletal radiotracer uptake on myocardial perfusion imaging with Tc-99m sestamibi [J].
Archana Gowda ;
Lisa Peddinghaus ;
Vijay Shandilya ;
Anna Gavriluke ;
Diwakar Jain .
Journal of Nuclear Cardiology, 2006, 13 :427-431
[47]   The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study [J].
Duvall, W. Lane ;
Wijetunga, Melanie N. ;
Klein, Thomas M. ;
Razzouk, Louai ;
Godbold, Jim ;
Croft, Lori B. ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) :370-377
[48]   RESULTS OF MYOCARDIAL SCINTIGRAPHY IN PATIENTS WITH LEFT-BUNDLE-BRANCH BLOCK USING TL-201 AND TC-99M-MIBI [J].
KNAPP, WH ;
SCHMIDT, U ;
BENTRUP, A ;
NOTOHAMIPRODJO, G ;
GLEICHMANN, U .
ZEITSCHRIFT FUR KARDIOLOGIE, 1991, 80 (12) :732-737
[49]   Can Carbonated Lime Drink Intake Prior to Myocardial Perfusion Imaging With Tc-99m MIBI Reduce the Extracardiac Activity That Degrades the Image Quality and Leads to Fallacies in Interpretation? [J].
Malhotra, Gaurav ;
Upadhye, Trupti S. ;
Nabar, Ashish ;
Asopa, Ramesh V. ;
Nayak, Uday N. ;
Rajan, M. G. Ramakrishna .
CLINICAL NUCLEAR MEDICINE, 2010, 35 (03) :160-164
[50]   RELATIONS OF THE MYOCARDIAL IMAGING AGENTS TC-99M-MIBI AND TL-201 TO MYOCARDIAL BLOOD-FLOW IN A CANINE MODEL OF MYOCARDIAL ISCHEMIC INSULT [J].
CANBY, RC ;
SILBER, S ;
POHOST, GM .
CIRCULATION, 1990, 81 (01) :289-296