REDUCED VARIABILITY OF INTERPRETATION AND IMPROVED IMAGE QUALITY WITH A TC-99M MYOCARDIAL PERFUSION AGENT - COMPARISON OF TL-201 AND TC-99M-LABELED TETROFOSMIN

被引:37
作者
HENDEL, RC
PARKER, MA
WACKERS, FJT
RIGO, P
LAHIRI, A
ZARET, BL
机构
[1] YALE UNIV,SCH MED,DEPT INTERNAL MED,DIV CARDIOVASC MED,NEW HAVEN,CT 06510
[2] STATE UNIV LIEGE,DEPT MED,DIV CARDIOL,B-4000 LIEGE,BELGIUM
[3] NORTHWICK PK HOSP & CLIN RES CTR,DEPT CARDIOL,HARROW HA1 3UJ,MIDDX,ENGLAND
关键词
TETROFOSMIN; THALLIUM; MYOCARDIAL PERFUSION IMAGING; RADIOISOTOPE; CORONARY ARTERY DISEASE;
D O I
10.1007/BF02939973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to determine the relative image quality and interobserver variability among four readers for Tl-201 and 99mTc-labeled tetrofosmin myocardial perfusion images. 99mTc-labeled perfusion agents, with near-optimal physical characteristics for gamma camera imaging, may allow for superior image quality and improved consistency of interpretation. However, most studies to date have demonstrated only similarity in the diagnostic accuracy between technetium agents and thallium. Tetrofosmin is a recently developed 99mTc-labeled agent that has shown promising results in early clinical trials. Methods and Results. A multicenter, open-label trial was performed during which treadmill exercise thallium and tetrofosmin scintigraphy was performed within a 2-week period of each other in 216 subjects. Image quality was evaluated subjectively and scans were interpreted in a blinded, independent fashion by four readers. Perfusion abnormalities were graded as consistent with ischemia, infarction, or mixed and were described both globally and regionally. Interobserver variability was assessed by use of the kappa statistic, and receiver-operator curves were compared for each observer for the diagnostic accuracy of each agent. More tetrofosmin images were of excellent quality than with thallium (52% vs 28%; p < 0.05), and when differences in quality were noted between the agents, tetrofosmin was more often superior (p < 0.0001). The interobserver variability was lower with tetrofosmin scintigraphy because generally higher kappa values were noted, especially in the lateral wall. Higher receiver-operator curve areas indicative of improved diagnostic accuracy were noted among the four readers for tetrofosmin in 80% of vascular territories. Conclusions. 99mTc-labeled tetrofosmin scintigraphy yields images of improved quality compared with thallium, and there is an overall improvement in the consistency of image analysis associated with the use of tetrofosmin.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 50 条
  • [21] Tc-99m tetrofosmin myocardial distribution 4 hours post injection
    Pillay, M
    Cox, PH
    Schonfeld, DHW
    Mathews, S
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (02): : 127 - 135
  • [22] Risk stratification of patients after myocardial revascularization by stress Tc-99m tetrofosmin myocardial perfusion tomography
    Abdou Elhendy
    Arend F. L. Schinkel
    Ron T. van Domburg
    Jeroen J. Bax
    Roelf Valkema
    Don Poldermans
    Journal of Nuclear Cardiology, 2003, 10 : 615 - 622
  • [23] Lung Mass Appearing as a Dilated Left Ventricle on Tc-99m Tetrofosmin Myocardial Perfusion Scintigraphy
    Gnanasegaran, Gopinath
    Williams, Robert
    Mclean, Emma
    O'Connell, Rachel
    Nunan, Thomas O.
    O'Doherty, Michael J.
    CLINICAL NUCLEAR MEDICINE, 2009, 34 (09) : 620 - 621
  • [24] Role of carbonated water technique to enhance Tc-99m tetrofosmin myocardial perfusion imaging by reducing subdiaphragmatic artefacts
    Hussain, Saba
    Sultan, Fateh Ali Tipoo
    ANNALS OF NUCLEAR MEDICINE, 2020, 34 (10) : 787 - 792
  • [25] Comparison of exercise-rest-reinjection Tl-201 imaging and rest sublingual isosorbide dinitrate Tc-99m MIBI imaging for the assessment of myocardial viability
    Gunel, Seval Erhamamci
    Akgun, Aysegul
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (05) : 451 - 457
  • [26] Technetium-99m tetrofosmin imaging in thyroid diseases: Comparison with Tc-99m-pertechnetate, thallium-201 and Tc-99m-methoxyisobutylisonitrile scans
    Klain, M
    Maurea, S
    Cuocolo, A
    Colao, A
    Marzano, L
    Lombardi, G
    Salvatore, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (12): : 1568 - 1574
  • [27] Comparison of Outcome After Myocardial Infarction in Patients With and Without Abnormalities on Previous Stress Tc-99m Tetrofosmin Myocardial Perfusion Imaging
    Elhendy, Abdou
    Schinkel, Arend F. L.
    van Domburg, Ron T.
    Bax, Jeroen J.
    Feringa, Harm H. H.
    Noordzij, Peter G.
    Schouten, Olaf
    Karagiannis, Stefanos E.
    Dunkelgrun, Martin
    Poldermans, Don
    CLINICAL NUCLEAR MEDICINE, 2008, 33 (12) : 852 - 855
  • [28] Prognostic implications of stress Tc-99m tetrofosmin myocardial perfusion imaging in patients with left ventricular hypertrophy
    Abdou Elhendy
    Arend F. L. Schinkel
    Ron T. van Domburg
    Jeroen J. Bax
    Harm H. H. Feringa
    Peter G. Noordzij
    Olaf Schouten
    Don Poldermans
    Journal of Nuclear Cardiology, 2007, 14 : 550 - 554
  • [29] Prognostic implications of stress Tc-99m tetrofosmin myocardial perfusion imaging in patients with left ventricular hypertrophy
    Elhendy, Abdou
    Schinkel, Arend F. L.
    van Domburg, Ron T.
    Bax, Jeroen J.
    Feringa, Harm H. H.
    Noordzij, Peter G.
    Schouten, Olaf
    Poldermans, Don
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) : 550 - 554
  • [30] Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT
    Hannequin, P
    Weinmann, P
    Mas, J
    Vinot, S
    JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (02) : 144 - 151