REDUCED VARIABILITY OF INTERPRETATION AND IMPROVED IMAGE QUALITY WITH A TC-99M MYOCARDIAL PERFUSION AGENT - COMPARISON OF TL-201 AND TC-99M-LABELED TETROFOSMIN

被引:37
|
作者
HENDEL, RC
PARKER, MA
WACKERS, FJT
RIGO, P
LAHIRI, A
ZARET, BL
机构
[1] YALE UNIV,SCH MED,DEPT INTERNAL MED,DIV CARDIOVASC MED,NEW HAVEN,CT 06510
[2] STATE UNIV LIEGE,DEPT MED,DIV CARDIOL,B-4000 LIEGE,BELGIUM
[3] NORTHWICK PK HOSP & CLIN RES CTR,DEPT CARDIOL,HARROW HA1 3UJ,MIDDX,ENGLAND
关键词
TETROFOSMIN; THALLIUM; MYOCARDIAL PERFUSION IMAGING; RADIOISOTOPE; CORONARY ARTERY DISEASE;
D O I
10.1007/BF02939973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to determine the relative image quality and interobserver variability among four readers for Tl-201 and 99mTc-labeled tetrofosmin myocardial perfusion images. 99mTc-labeled perfusion agents, with near-optimal physical characteristics for gamma camera imaging, may allow for superior image quality and improved consistency of interpretation. However, most studies to date have demonstrated only similarity in the diagnostic accuracy between technetium agents and thallium. Tetrofosmin is a recently developed 99mTc-labeled agent that has shown promising results in early clinical trials. Methods and Results. A multicenter, open-label trial was performed during which treadmill exercise thallium and tetrofosmin scintigraphy was performed within a 2-week period of each other in 216 subjects. Image quality was evaluated subjectively and scans were interpreted in a blinded, independent fashion by four readers. Perfusion abnormalities were graded as consistent with ischemia, infarction, or mixed and were described both globally and regionally. Interobserver variability was assessed by use of the kappa statistic, and receiver-operator curves were compared for each observer for the diagnostic accuracy of each agent. More tetrofosmin images were of excellent quality than with thallium (52% vs 28%; p < 0.05), and when differences in quality were noted between the agents, tetrofosmin was more often superior (p < 0.0001). The interobserver variability was lower with tetrofosmin scintigraphy because generally higher kappa values were noted, especially in the lateral wall. Higher receiver-operator curve areas indicative of improved diagnostic accuracy were noted among the four readers for tetrofosmin in 80% of vascular territories. Conclusions. 99mTc-labeled tetrofosmin scintigraphy yields images of improved quality compared with thallium, and there is an overall improvement in the consistency of image analysis associated with the use of tetrofosmin.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 50 条
  • [1] A comparison of Tl-201, Tc-99m sestamibi, and Tc-99m tetrofosmin myocardial perfusion scintigraphy in patients with mild to moderate coronary stenosis
    Reyes, Ellana
    Loong, Chee Y.
    Harbinson, Mark
    Rahman, Shelley
    Prvulovich, Elizabeth
    Ell, Peter J.
    Anagnostopoulos, Constantinos
    Underwood, S. Richard
    JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (04) : 488 - 494
  • [2] A comparison of Tl-201, Tc-99m sestamibi, and Tc-99m tetrofosmin myocardial perfusion scintigraphy in patients with mild to moderate coronary stenosis
    Eliana Reyes
    Chee Y. Loong
    Shelley Rahman
    S. Richard Underwood
    Mark Harbinson
    Constantinos Anagnostopoulos
    Elizabeth Prvulovich
    Peter J. Ell
    Journal of Nuclear Cardiology, 2006, 13 : 488 - 494
  • [3] Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: Technical, physiologic, and clinical issues
    Purushothaman Kailasnath
    Albert J. Sinusas
    Journal of Nuclear Cardiology, 2001, 8 : 482 - 498
  • [4] SCINTIGRAPHIC ASSESSMENT OF MYOCARDIAL PERFUSION USING TL-201 AND TC-99M IMAGING
    BLACKBURN, T
    BELLER, G
    CORONARY ARTERY DISEASE, 1992, 3 (04) : 274 - 280
  • [5] Reproducibility of Tl-201 and Tc-99m sestamibi gated myocardial perfusion SPECT measurement of myocardial function
    Hyun, IY
    Kwan, J
    Park, KS
    Lee, WH
    JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (02) : 182 - 187
  • [6] MYOCARDIAL PERFUSION IMAGING WITH TECHNETIUM-99M-TC NOET - COMPARISON WITH TL-201 AND CORONARY ANGIOGRAPHY
    FAGRET, D
    MARIE, PY
    BRUNOTTE, F
    GIGANTI, M
    LEGULUDEC, D
    BERTRAND, A
    WOLF, JE
    PIFFANELLI, A
    CHOSSAT, F
    BEKHECHI, D
    PASQUALINI, R
    MACHECOURT, J
    COMET, M
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (06) : 936 - 943
  • [7] Left-ventricular dyssynchrony evaluated by Tl-201 gated SPECT myocardial perfusion imaging: a comparison with Tc-99m sestamibi
    Chen, Chien-Cheng
    Huang, Wen-Sheng
    Hung, Guang-Uei
    Chen, Wan-Chen
    Kao, Chia-Hung
    Chen, Ji
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (03) : 229 - 232
  • [8] Lessons From the Tc-99m Shortage Implications of Substituting Tl-201 for Tc-99m Single-Photon Emission Computed Tomography
    Small, Gary R.
    Ruddy, Terrence D.
    Simion, Oana
    Alam, Mohammed
    Fuller, Lyanne
    Chen, Li
    Beanlands, Rob S.
    Chow, Benjamin J. W.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (05) : 683 - 691
  • [9] THE NEW TC-99M MYOCARDIAL PERFUSION IMAGING AGENTS - TC-99M-SESTAMIBI AND TC-99M-TEBOROXIME
    BERMAN, DS
    KIAT, H
    MADDAHI, J
    CIRCULATION, 1991, 84 (03) : I7 - I21
  • [10] MYOCARDIAL PERFUSION IMAGING WITH TC-99M TETROFOSMIN - COMPARISON TO (TL)-T-201 IMAGING AND CORONARY ANGIOGRAPHY IN A PHASE-III MULTICENTER
    ZARET, BL
    RIGO, P
    WACKERS, FJT
    HENDEL, RC
    BRAAT, SH
    ISKANDRIAN, AS
    SRIDHARA, BS
    JAIN, D
    ITTI, R
    SERAFINI, AN
    GORIS, ML
    LAHIRI, A
    HALDERS, S
    KOPPEJANS, L
    CAJOB, I
    WILLEMS, P
    BONTEMPS, L
    EGROIZARD, P
    SAYEGH, Y
    FRAYSSE, M
    BENOIT, TR
    LELLERLO, B
    FOULON, J
    KLINE, R
    MORRISSETTE, G
    PRICE, L
    JACKSON, R
    SPIES, S
    BELLOW, S
    LEONARD, S
    BULL, C
    SRIDHARA, B
    RAVAL, U
    CRAWLEY, J
    SMITH, T
    ISKANDRIAN, A
    HEO, J
    UNTEEKER, W
    FEINSMITH, N
    CAVE, V
    WASSERLEBEN, V
    MCDOUGALL, R
    BLAKE, L
    GUREVICH, N
    FUJII, C
    EZUDDIN, S
    SEQUEIRA, R
    LOWERY, M
    WACKERS, FJ
    MATTERA, J
    CIRCULATION, 1995, 91 (02) : 313 - 319