Comparison of Intraocular Lens Power Calculation Methods after Refractive Surgery Provided by the ASCRS

被引:1
|
作者
Jung, Soyeon [1 ]
Jung, Jiwon [1 ]
机构
[1] Inha Univ, Dept Ophthalmol, Sch Med, Incheon, South Korea
来源
关键词
American Society of Cataract and Refractive Surgery (ASCRS) intraocular lens (IOL) calculator; Cataract; Corneal refractive surgery; IOL power calculation;
D O I
10.3341/jkos.2018.59.9.827
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Methods of intraocular lens (IOL) calculations for cataract surgery after myopic corneal refractive surgery were compared. Methods: The medical records of 23 eyes from 20 patients were retrospectively analyzed. Five methods - Haigis L and Barrett no history method from Post-Refractive IOL Calculator of American Society of Cataract and Refractive Surgery (ASCRS), Shammas no history method, Haigis suite from IOL Master 700, and clinical history method - were used. Results: The Barrette no history method from the ASCRS showed the lowest arithmetic errors, while the Haigis-L from the ASCRS showed the lowest absolute prediction errors (-0.38 +/- 0.99 diopters [D] and 0.76 +/- 0.68 D, respectively). The percentages of refractive prediction errors within 0.50 D and 1.00 D of the Barrett no history method were 52.2% and 82.6%, respectively. Conclusions: The Barrette no history method and Haigis-L from the ASCRS showed the smallest errors in this study. The Barrett no history method showed a high percentage of refractive prediction errors within 0.50 D and 1.00 D.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 50 条
  • [11] Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery
    Wu, Yubo
    Liu, Songyu
    Liao, Rongfeng
    BMC OPHTHALMOLOGY, 2017, 17
  • [12] Intraocular Lens Power Calculation After Refractive Surgery and Technologic Improvements
    Can, Cigdem
    Ilhan, Bayazit
    Polat, Sibel
    Zilelioglu, Orhan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2006, 36 (05): : 384 - 388
  • [13] Intraocular lens power calculation in eyes after corneal refractive surgery
    Seitz, B
    Langenbucher, A
    JOURNAL OF REFRACTIVE SURGERY, 2000, 16 (03) : 349 - 361
  • [14] Updated practical intraocular lens power calculation after refractive surgery
    Jonna, Gowtham
    Channa, Prabjot
    CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (04) : 275 - 280
  • [15] Intraocular lens power calculation after previous laser refractive surgery
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04): : 759 - 765
  • [16] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [17] Comparative Analysis of Accuracy and Predictability of Intraocular Lens Power Calculation after Refractive Surgery: Conventional Regression Formula versus ASCRS Calculator
    Kang, Byeong Soo
    Oh, Joo Youn
    Kim, Mee Kum
    Wee, Won Ryang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [18] A new formula for intraocular lens power calculation after refractive corneal surgery
    Camellin, M
    Calossi, A
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) : 187 - 199
  • [19] Intraocular lens power calculation with the Scheimpflug camera after refractive surgery Reply
    Saiki, Megumi
    Negishi, Kazuno
    Kato, Naoko
    Ogino, Rika
    Arai, Hiroyuki
    Toda, Ikuko
    Dogru, Murat
    Tsubota, Kazuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (08): : 1280 - 1281
  • [20] Intraocular lens power calculation after corneal refractive surgery remains challenging
    Sun, R
    Gimbel, H
    Penno, EEA
    OPHTHALMOLOGY, 2000, 107 (02) : 226 - 227