EXPERIMENTAL-STUDY ON THE EFFECTS OF CHANNEL GAP SIZE ON MIXED CONVECTION HEAT-TRANSFER CHARACTERISTICS IN VERTICAL RECTANGULAR CHANNELS HEATED FROM BOTH SIDES

被引:15
作者
SUDO, Y [1 ]
KAMINAGA, M [1 ]
MINAZOE, K [1 ]
机构
[1] NIPPON KOKAN KK, KAWASAKI KU, KAWASAKI 210, JAPAN
关键词
D O I
10.1016/0029-5493(90)90368-8
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The effects of channel gap size on mixed forced and free convective heat transfer characteristics were experimentally investigated for water flowing near atmospheric pressure in a 750 mm long and 50 mm wide channel heated from both sides. The channel gap sizes investigated were 2.5, 6, 18 and 50 mm. Experiments were carried out for both aiding and opposing forced convective flows with a Reynolds number Rex of 4 × 10 to 6 × 106 and a Grashof number Grx of 2 × 104 to 6 × 1011, where the distance x from the inlet of the channel is adopted as the characteristic length in Rex and Grx. As for the results, the following were revealed for the parameters ranges investigated in this study. 1. (1) When the dimensionless parameter, Grx/Rex 21 8Pr 1 2 is less than 10-4, the flow shows the nature of forced convective heat transfer for a channel with any channel gap size in both aiding and opposing flows. 2. (2) When Grx/Rex 21 8Pr 1 2 is larger than 10-2, the flow shows the nature of free convective heat transfer for a channel with any channel gap size in both aiding and opposing flows. 3. (3) When Grx/Rex 21 8Pr 1 2 is between 10-4 and 10-2 for the channel with a channel gap size equal to or larger than 6 mm, the heat transfer coefficients in both aiding and opposing flows become, on the average, higher than those predicted by the previous correlations for either the pure turbulent forced convection or the pure free convection, and can be expressed in simple forms with a combination of Grx/Rex 21 8Pr 1 2 and the previous correlation for either the pure turbulent forced convection or the free convection along a flat plate. 4. (4) When Grx/Rex 21 8{Pr 1 2 is between 10-4 and 10-2 for the channel with a channel gap size of 2.5 mm, the heat transfer coefficients in both aiding and opposing flows also become, on the average, higher than those predicted by the previous correlations for either the pure turbulent forced convection or the pure free convection. This is considered to be because the acceleration of the main flow originated by the development of the boundary layer in a narrow rectangular channel promotes the heat transfer. © 1990.
引用
收藏
页码:135 / 146
页数:12
相关论文
共 19 条
[1]  
Axcell B. P., 1978, Sixth International Heat Transfer Conference, P37
[2]  
Dittus F.W., 1930, U CALIF BERKELEY PUB, V2, P433
[3]  
ECKERT ERG, 1954, T AM SOC MECH ENG, V76, P497
[4]  
FAGE A, 1931, BR AERONOUT RES COMM, P1405
[5]  
FUJII T, 1970, INT J HEAT MASS TRAN, V13, P607, DOI 10.1016/0017-9310(70)90155-9
[6]   ANALYTICAL STUDY ON THERMAL-HYDRAULIC BEHAVIOR OF TRANSIENT FROM FORCED CIRCULATION TO NATURAL CIRCULATION IN JRR-3 [J].
HIRANO, M ;
SUDO, Y .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1986, 23 (04) :352-368
[7]   FINITE DIFFERENCE ANALYSIS OF FORCED-CONVECTION HEAT TRANSFER IN ENTRANCE REGION OF A FLAT RECTANGULAR DUCT [J].
HWANG, CL ;
FAN, LT .
APPLIED SCIENTIFIC RESEARCH SECTION A-MECHANICS HEAT CHEMICAL ENGINEERING MATHEMATICAL METHODS, 1964, 13 (06) :401-&
[8]  
Jackson J.D., 1979, TURBULENT FORCED CON, V2, P563
[9]  
Jackson J.D., 1977, HEAT TRANSFER TURBUL, V2, P759
[10]  
Karman T. V., 1939, T AM SOC MECH ENG, V61, P705