PULL-OUT STRENGTH OF SCREWS FROM POLYMETHYLMETHACRYLATE CEMENT

被引:26
作者
MOTZKIN, NE [1 ]
CHAO, EYS [1 ]
AN, KN [1 ]
WIKENHEISER, MA [1 ]
LEWALLEN, DG [1 ]
机构
[1] MAYO CLIN & MAYO FDN,DEPT ORTHOPAED,ORTHOPAED BIOMECH LAB,ROCHESTER,MN 55905
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1994年 / 76B卷 / 02期
关键词
D O I
10.1302/0301-620X.76B2.8113302
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We aimed to determine the optimal method of inserting a screw into polymethylmethacrylate (PMMA) cement to enhance fixation. We performed six groups of ten axial pull-out tests with two sizes of screw (3.5 and 4.5 mm AO cortical) and three methods of insertion. Screws were placed into 'fluid' PMMA, into 'solid' PMMA by drilling and tapping, or into 'curing' PMMA with quarter-revolution turns every 30 seconds until the PMMA had hardened. After full hardening, we measured the maximum load to failure for each screw-PMMA construct. We found no significant difference in the pull-out strengths between screw sizes or between screws placed in fluid or solid PMMA. Screws placed in curing PMMA were significantly weaker: the relative strengths of solid, fluid and curing groups were 100%, 97% and 71%, respectively. We recommend the use of either solid or fluid insertion according to the circumstances and the preference of the surgeon.
引用
收藏
页码:320 / 323
页数:4
相关论文
共 12 条
[1]   USE OF POLYMETHYLMETHACRYLATE TO ENHANCE SCREW FIXATION IN BONE [J].
CAMERON, HU ;
JACOB, R ;
MACNAB, I ;
PILLIAR, RM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (05) :655-656
[2]  
Daum W J, 1988, J Orthop Trauma, V2, P229, DOI 10.1097/00005131-198802030-00009
[3]   HOLDING POWER OF DIFFERENT SCREWS IN THE FEMORAL-HEAD - A STUDY IN HUMAN CADAVER HIPS [J].
FRANDSEN, PA ;
CHRISTOFFERSEN, H ;
MADSEN, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03) :349-351
[4]  
FRANKEL VH, 1970, ORTHOPAEDIC BIOMECHA
[5]  
GOZNA ER, 1982, BIOMECHANICS MUSCULO, V87, P129
[6]   METHYLMETHACRYLATE AS AN ADJUNCT IN INTERNAL-FIXATION OF PATHOLOGICAL FRACTURES - EXPERIENCE WITH 375 CASES [J].
HARRINGTON, KD ;
SIM, FH ;
ENIS, JE ;
JOHNSTON, JO ;
DICK, HM ;
GRISTINA, AG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (08) :1047-1055
[7]   MECHANICAL PROPERTIES OF SURGICAL BONE SCREWS AND SOME ASPECTS OF INSERTION PRACTICE [J].
HUGHES, AN ;
JORDAN, BA .
INJURY-THE BRITISH JOURNAL OF ACCIDENT SURGERY, 1972, 4 (01) :25-&
[8]   SCREW FIXATION IN THE FEMORAL-HEAD - PULL-OUT TESTS IN CADAVERS [J].
IVERSEN, BF ;
STURUP, J ;
LYNDRUP, P ;
JENSEN, NC ;
THERKILDEN, MH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (06) :655-657
[9]  
Oberg E., 1988, MACHINERYS HDB REFER
[10]  
SCHATZKER J, 1975, CLIN ORTHOP RELAT R, V108, P115