USE OF VICRYL (POLYGLACTIN-910) MESH IMPLANT FOR CORRECTING ENOPHTHALMOS AND HYPOOPHTHALMOS - A STUDY OF 16 PATIENTS

被引:13
|
作者
MAURIELLO, JA
MCSHANE, R
VOGLINO, J
机构
[1] Department of Plastic surgery, Mountainside Hospital, NJ, Montclair
[2] Department of Ophthalmology, UMD-New Jersey Medical School, Eye Institute of New Jersey, Newark
关键词
Orbital floor fracture; Orbital floor implant; Silicone implant; Vicryl mesh;
D O I
10.1097/00002341-199012000-00004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Vicryl mesh (polyglactin-910) implants were used to reconstruct the orbital floor to correct enophthalmos or hypo-ophthalmos (globe ptosis) in 16 patients. The main advantages of Vicryl mesh over other alloplastic implants is that (a) it is absorbed by host tissues, and, once absorbed, it will not cause long-term complications; (b) it is layered and is cut from folded sheets into the appropriate size, shape, and thickness for the treatment of enophthalmos or hypo-ophthalmos; and (c) it is soft and pliable and, therefore, is unlikely to erode orbital structures. We followed all 16 patients for a minimum period of 6 months after surgery and observed no significant adverse reactions to the mesh; 15 of the patients had good surgical results with a mean improvement of 1.4 mm in enophthalmos and 0.6 mm in hypo-ophthalmos. After surgery, one patient with combined medial wall and floor fractures developed enophthalmos that was 2 mm more severe than the degree of preoperative enophthalmos. Vicryl mesh should be considered an alternative to both nonautoge-nous implants and autogenous grafts in orbital floor fracture repair especially for correction of mild and possibly moderate degrees of enophthalmos and hypo-ophthalmos. © 1990 Raven Press, Ltd., New York.
引用
收藏
页码:247 / 251
页数:5
相关论文
共 4 条
  • [1] USE OF VICRYL (POLYGLACTIN-910) MESH IMPLANT FOR REPAIR OF ORBITAL FLOOR FRACTURE CAUSING DIPLOPIA - A STUDY OF 28 PATIENTS OVER 5 YEARS
    MAURIELLO, JA
    WASSERMAN, B
    KRAUT, R
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 9 (03) : 191 - 195
  • [2] THE USE OF VICRYL MESH (POLYGLACTIN-910) FOR IMPLANTATION OF HYDROXYAPATITE ORBITAL IMPLANTS
    JORDAN, DR
    ALLEN, LH
    ELLS, A
    GILBERG, S
    BROWNSTEIN, S
    MUNRO, S
    GRAHOVAC, S
    RAYMOND, F
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 11 (02) : 95 - 99
  • [3] USE OF VICRYL (POLYGLACTIN-910) MESH TO LIMIT EPIDURAL SCAR FORMATION AFTER LAMINECTOMY
    NUSSBAUM, CE
    MCDONALD, JV
    BAGGS, RB
    NEUROSURGERY, 1990, 26 (04) : 649 - 654
  • [4] Outcomes of abdominal wall closure with fascial bridging using a polyglactin 910 (Vicryl) Mesh following non-trauma laparotomy: a multi-center study
    Nir Messer
    Alex Bertke
    Benjamin T. Miller
    Lucas R. A. Beffa
    Clayton C. Petro
    David M. Krpata
    Guy Lahat
    Eran Nizri
    Adam Abu-Abeid
    Fahim kanani
    Yonatan Lessing
    John McMichael
    Michael J. Rosen
    Ajita S. Prabhu
    Hernia, 29 (1)