MEASUREMENT OF VERY SHORT FLUORESCENCE LIFETIMES BY SINGLE-PHOTON COUNTING

被引:45
作者
HARTIG, PR
SAUER, K
LO, CC
LESKOVAR, B
机构
[1] UNIV CALIF BERKELEY,CHEM BIODYNAM LAB,BERKELEY,CA 94720
[2] UNIV CALIF,LAWRENCE LIVERMORE LAB,LIVERMORE,CA 94550
关键词
PHOTODETECTORS;
D O I
10.1063/1.1134834
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Measurement of very shoft fluorescence lifetimes by the single-photon technique is made possible by an improved fluorescence lifetime system. Fluorescence lifetimes of 4. 94 plus or minus 0. 07 nsec for anthracene in cyclohexane, 640 plus or minus 30 psec for diphenyl butadiene in cyclohexane, and 90 plus or minus 30 psec for erythrosin in water were determined. Complications in the analysis of lifetime data introduced by intrinsic fluorescence and phosphorescence processes in commonly used absorption filters are discussed. Certain ″blind spots″ are found in the electronic pulse pileup rejection schemes most commonly used in photon counting.
引用
收藏
页码:1122 / 1129
页数:8
相关论文
共 26 条
[11]  
ISENBERG I, 1969, BIOPHYS J, V9, P1338
[12]   SINGLE PHOTON DECAY SPECTROSCOPY [J].
KNIGHT, AEW ;
SELINGER, BK .
AUSTRALIAN JOURNAL OF CHEMISTRY, 1973, 26 (01) :1-27
[13]   PHOTON-COUNTING SYSTEM FOR SUBNANOSECOND FLUORESCENCE LIFETIME MEASUREMENTS [J].
LESKOVAR, B ;
LO, CC ;
HARTIG, PR ;
SAUER, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (09) :1113-1121
[14]   PERFORMANCE STUDIES OF PHOTOMULTIPLIERS HAVING DYNODES WITH GAP(CS) SECONDARY EMITTING SURFACE [J].
LESKOVAR, B ;
LO, CC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (03) :50-+
[15]   MEASUREMENT OF SHORT-LIVED FLUORESCENCE DECAY USING SINGLE PHOTON-COUNTING METHOD [J].
LEWIS, C ;
WARE, WR ;
DOEMENY, LJ ;
NEMZEK, TL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (02) :107-114
[16]   PICOSECOND KINETICS OF SPONTANEOUS FLUORESCENCE OF ERYTHROSIN-B [J].
MOUROU, G ;
MALLEY, MM .
OPTICS COMMUNICATIONS, 1974, 11 (03) :282-284
[17]   INSTRUMENTAL RESPONSE TIME CORRECTIONS IN FLUORESCENCE DECAY MEASUREMENTS [J].
MUNRO, IH ;
RAMSAY, IA .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (02) :147-&
[18]   TIME RESOLVED FLUORESCENCE IN PICOSECOND REGION [J].
PORTER, G ;
REID, ES ;
TREDWELL, CJ .
CHEMICAL PHYSICS LETTERS, 1974, 29 (03) :469-472
[19]   MONOPHOTON FLUOROMETER WITH ENERGY DISCRIMINATION [J].
SCHUYLER, R ;
ISENBERG, I .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (06) :813-&
[20]   MEASUREMENT OF SUBNANOSECOND LIFETIMES BY MONOPHOTON FLUOROMETRY [J].
SCHUYLER, R ;
ISENBERG, I ;
DYSON, RD .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1972, 15 (04) :395-&