TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS WITH GIANTURCO COILS

被引:203
作者
LLOYD, TR
FEDDERLY, R
MENDELSOHN, AM
SANDHU, SK
BEEKMAN, RH
机构
[1] CS MOTT CHILDRENS HOSP,DEPT PEDIAT,DIV PEDIAT CARDIOL,ANN ARBOR,MI
[2] UNIV MICHIGAN,ANN ARBOR,MI 48109
[3] UNIV ARIZONA,DEPT PEDIAT CARDIOL,TUCSON,AZ 85721
关键词
BRIEF COMMUNICATIONS; OCCLUSIONS; PATENT DUCTUS ARTERIOSUS;
D O I
10.1161/01.CIR.88.4.1412
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transcatheter occlusion with Gianturco coils has been attempted in a small number of patients with tiny (less-than-or-equal-to 1.5-mm diameter) patent ductus arteriosus, and preliminary results have been encouraging. The present study extends this method to larger ductus sizes and makes recommendations for proper coil size selection. Methods and Results. Coil occlusion was attempted in 24 consecutive patients with patent ductus arteriosus who did not require other cardiac surgery. Median patient age was 4.2 years (8 months to 30 years), and mean ductus diameter was 1.7+/-0.8 mm. Two instances of coil embolization occurred in the first 4 patients, with successful coil retrieval. Based on this experience, we proposed that the coil helical diameter should be twice or more the minimum ductus diameter, with coil length sufficient for three or more loops. With these recommendations, coils were successfully implanted in the subsequent 20 consecutive patients. Of the 22 patients with successful coil implantation, 15 (68%) had no residual shunting, and 7 had trace residual shunting by angiography. The continuous murmur was abolished in all 22 patients. No significant complications occurred, and all patients were discharged within 24 hours of successful coil implantation. No change in the systolic pressure gradient between main and left pulmonary artery or ascending and descending aorta was observed. Conclusions. Transcatheter occlusion of patent ductus arteriosus can be safely and effectively achieved in patients with ductus diameters up to 3.3 mm. Coil occlusion does not cause obstruction to flow in the left pulmonary artery or descending aorta. Coils should be selected to provide a helical diameter twice or more the minimum ductus diameter and a length sufficient for three or more loops.
引用
收藏
页码:1412 / 1420
页数:9
相关论文
共 50 条
[31]   TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS - SUCCESSFUL USE IN A 3.5-KILOGRAM INFANT [J].
RASHKIND, WJ ;
CUASO, CC .
PEDIATRIC CARDIOLOGY, 1979, 1 (01) :3-7
[32]   Outcomes of Transcatheter Occlusion of Patent Ductus Arteriosus in Infants Weighing ≤6 kg [J].
Dimas, V. Vivian ;
Takao, Cheryl ;
Ing, Frank F. ;
Mattamal, Raphael ;
Mbbs, Alan W. Nugent ;
Grifka, Ronald G. ;
Mullins, Charles E. ;
Justino, Henri .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (12) :1295-1299
[33]   Unraveling of a Gianturco coil during reocclusion of a patent ductus arteriosus [J].
Justo, RN ;
Nykanen, DG ;
Benson, LN .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 38 (02) :184-185
[34]   A strategic approach to transcatheter closure of patent ductus: Gianturco coils for small-to-moderate ductus and Amplatzer duct occluder for large ductus [J].
Wang, JK ;
Hwang, JJ ;
Chiang, FT ;
Wu, MH ;
Lin, MT ;
Lee, WL ;
Lue, HC .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 106 (01) :10-15
[35]   Transcatheter coil occlusion of patent ductus arteriosus and follow-up results [J].
Atik, Sezen Ugan ;
Saltik, Irfan Levant .
TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2019, 47 (04) :265-272
[36]   Transcatheter Occlusion of a Patent Ductus Arteriosus for a Symptomatic Left-to-Right Shunt [J].
Keita, Papus ;
Han, Frank ;
Peterman, Nicholas J. ;
Toledo, Sandor ;
Munaco, Anthony .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (05)
[37]   Transcatheter Device Closure of Patent Ductus Arteriosus [J].
Sultan, Mehboob ;
Ullah, Maad ;
Sadiq, Nadeem ;
Akhtar, Khurram ;
Akbar, Hajira .
JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2014, 24 (10) :710-713
[38]   Transcatheter Occlusion of the Patent Ductus Arteriosus in Infants: Experimental Testing of a New Amplatzer Device [J].
Bass, John L. ;
Wilson, Neil .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (02) :250-255
[39]   SPRING COIL EMBOLIZATION OF A PATENT DUCTUS-ARTERIOSUS IN AN ADULT [J].
LAIRD, JR ;
SLACK, MC ;
GURCZAK, P ;
GORMAN, PD ;
WORTHAM, DC .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 18 (04) :259-261
[40]   Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device [J].
Philip, Ranjit ;
Waller, B. Rush, III ;
Agrawal, Vijaykumar ;
Wright, Dena ;
Arevalo, Alejandro ;
Zurakowski, David ;
Sathanandam, Shyam .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (02) :310-317