Background. Transcatheter occlusion with Gianturco coils has been attempted in a small number of patients with tiny (less-than-or-equal-to 1.5-mm diameter) patent ductus arteriosus, and preliminary results have been encouraging. The present study extends this method to larger ductus sizes and makes recommendations for proper coil size selection. Methods and Results. Coil occlusion was attempted in 24 consecutive patients with patent ductus arteriosus who did not require other cardiac surgery. Median patient age was 4.2 years (8 months to 30 years), and mean ductus diameter was 1.7+/-0.8 mm. Two instances of coil embolization occurred in the first 4 patients, with successful coil retrieval. Based on this experience, we proposed that the coil helical diameter should be twice or more the minimum ductus diameter, with coil length sufficient for three or more loops. With these recommendations, coils were successfully implanted in the subsequent 20 consecutive patients. Of the 22 patients with successful coil implantation, 15 (68%) had no residual shunting, and 7 had trace residual shunting by angiography. The continuous murmur was abolished in all 22 patients. No significant complications occurred, and all patients were discharged within 24 hours of successful coil implantation. No change in the systolic pressure gradient between main and left pulmonary artery or ascending and descending aorta was observed. Conclusions. Transcatheter occlusion of patent ductus arteriosus can be safely and effectively achieved in patients with ductus diameters up to 3.3 mm. Coil occlusion does not cause obstruction to flow in the left pulmonary artery or descending aorta. Coils should be selected to provide a helical diameter twice or more the minimum ductus diameter and a length sufficient for three or more loops.
引用
收藏
页码:1412 / 1420
页数:9
相关论文
共 50 条
  • [1] Transcatheter closure of patent ductus arteriosus using Gianturco coils in adolescents and adults
    Wang, JK
    Liau, CS
    Huang, JJ
    Hsu, KL
    Lo, PH
    Hung, JS
    Wu, MH
    Lee, YT
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (04) : 513 - 518
  • [2] Transcatheter occlusion of patent ductus arteriosus using tornado platinum coils
    Suda, K
    Matsumura, M
    PEDIATRICS INTERNATIONAL, 2003, 45 (01) : 45 - 48
  • [3] REOCCLUSION OF RESIDUAL LEAKS AFTER TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS
    ABBAG, F
    GALAL, O
    FADLEY, F
    OUFI, S
    EUROPEAN JOURNAL OF PEDIATRICS, 1995, 154 (07) : 518 - 521
  • [4] Transcatheter closure of patent ductus arteriosus in children weighing <10kg with Gianturco coils using the balloon occlusion technique
    Dalvi, B
    Nabar, A
    Goyal, V
    Naik, A
    Kulkarni, H
    Ramakanthan, R
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 44 (03): : 303 - 308
  • [5] Transarterial occlusion of patent ductus arteriosus with Gianturco coils in pediatric patients: a preliminary result in central Taiwan
    Lee, ML
    Chaou, WT
    Wang, JK
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 69 (01) : 57 - 63
  • [6] Transcatheter closure of the patent ductus arteriosus in adults using the Gianturco coil
    Ing, FF
    Mullins, CE
    Rose, M
    Shapir, Y
    Bierman, FZ
    CLINICAL CARDIOLOGY, 1996, 19 (11) : 875 - 879
  • [7] Transcatheter closure of a patent ductus arteriosus in an elderly patient with the Gianturco-Grifka vascular occlusion device
    Befeler, B
    Justiniano, A
    Zahn, E
    CLINICAL CARDIOLOGY, 2000, 23 (10) : 790 - 791
  • [8] Mechanical occlusion of the patent ductus arteriosus with Jackson coils
    El Sisi, A
    Tofeig, M
    Arnold, R
    Peart, I
    Kitchiner, DJ
    Bu'Lock, FA
    Walsh, KP
    PEDIATRIC CARDIOLOGY, 2001, 22 (01) : 29 - 33
  • [9] Radiographic characteristics of Cook detachable and Gianturco coils as well as clinical results of transcatheter closure of the patent ductus arteriosus
    Galal, MO
    von Sinner, W
    Al-Fadley, F
    Solymar, L
    Bulbul, Z
    Boecker, J
    Fawzy, ME
    ZEITSCHRIFT FUR KARDIOLOGIE, 1999, 88 (12): : 1006 - 1014
  • [10] Transcatheter Patent Ductus Arteriosus Occlusion in Small Infants
    Schwartz, Matthew C.
    Nykanen, David
    Winner, Lawrence H.
    Perez, Jose
    McMahan, Michael
    Munro, Hamish M.
    Narasimhulu, Sukumar Suguna
    CONGENITAL HEART DISEASE, 2016, 11 (06) : 647 - 655